13.07.2015 Views

PFW3 00 A - SMC ETech

PFW3 00 A - SMC ETech

PFW3 00 A - SMC ETech

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

For WaterDigital Flow Switch Series PFWHow to OrderRemote TypeDisplay Unit<strong>PFW3</strong> 0 0 A01Flow rate range10230.5 to 4l/min2 to 16l/min5 to 40l/min10 to 1<strong>00</strong>l/minOutput specificationNPN open collector 2 outputsPNP open collector 2 outputsMountingA Panel mountingB DIN rail, wall mountingDIN rail type for <strong>PFW3</strong>30-B (for 1<strong>00</strong>l/min)is a semi-standard option.Panel mount adapter part no.DescriptionPart No.Panel adapter BZS-22-02Unit specificationNilMWith unit switching functionFixed SI unit Note)Note) Fixed units:Real-time flow rate: l/minAccumulated flow: lSpecificationsModelFlow rate measurementand set flow rate rangeMinimum setting unitNote 1) Real-time flow rateDisplay unitsAccumulated flowAccumulated flow rangeOperating temperature rangeLinearity Note 2)Repeatability Note 2)Temperature characteristics Note 2)<strong>PFW3</strong>10 <strong>PFW3</strong>11 <strong>PFW3</strong><strong>00</strong> <strong>PFW3</strong>01 <strong>PFW3</strong>20 <strong>PFW3</strong>210.5 to 4(setting is 0.6 to 4) l/min0.05l/min0.0 to 99999.9l<strong>PFW3</strong>30<strong>PFW3</strong>312 to 16l/min 5 to 40l/min 10 to 1<strong>00</strong>l/min0.1l/min 0.5l/min 1l/minl/min, gal (US)/minl, gal (US)0 to 999999l0° to 50°C (with no condensation)±5% F.S. or less±3%F.S. or less±3% F.S. or less±1%F.S. or less±5% F.S. or less (0° to 50°C)±1%F.S. or less (15° to 35°C)±2%F.S. or less (0° to 50°C)Output Note 3)specificationsIndicator lightsResponse timeHysteresisPower supply voltageCurrent consumptionWeightEnclosureSwitch outputNPN open collectorPNP open collectorMaximum load current: 80mAMaximum applied voltage: 30VInternal voltage drop: 1V or less (with load current of 80mA)Maximum load current: 80mAInternal voltage drop: 1.5V or less (with load current of 80mA)Lights up when output is ON, OUT1: Green; OUT2: Red1 sec. or lessHysteresis mode: Variable (can be set from 0)Window comparator mode: 3-digit fixed Note 4)12 to 24VDC (ripple ±10% or less)50mA or lessNote 1) For digital flow switch with unit switching function. (Fixed SI unit [l/min or l] will be set for switch types without the unit switching function.)Note 2) The system accuracy when combined with PFW5.Note 3) The output functions operate only for the real-time flow rate display, and do not operate for the accumulated flow display.Note 4) Window comparator mode — Since hysteresis will reach 3 digits, keep P1 and P2 apart by 7 digits or more. The minimum setting unit is 1 digit. (refer to the table above).45gIP4060mA or less21


Series PFWDimensions: Remote Type Display Unit for Water<strong>PFW3</strong>-APanel mounting typeInternal circuits and wiring examplesSensor41.8404.340.3Blue Brown BlackN.C.1 2 3 440<strong>SMC</strong> FLOW SWITCHUNIT35.8A56 7 8OUT1 OUT2LoadLoadRESETSET12 to 24VDC– +<strong>PFW3</strong>0-(-M)6.43 x 7.2 (= 21.6)8-M3Panel fitting dimension36 +0.50Sensor12 3 4Blue Brown BlackN.C.1 2 3 419.4+0.503656 7 8OUT1 OUT25 6 7 812 to 24VDCView A∗ The applicable panel thickness is 1 to 3.2mm.<strong>PFW3</strong>-BDIN rail type6.43 x 7.2 (= 21.6)8-M32-ø3.4361512 3 4<strong>SMC</strong> FLOW SWITCH265644UNIT35.5RESETSET(4.5)293815.2– +LoadLoad<strong>PFW3</strong>1-(-M)ø6.5305 6 7 830

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!