13.07.2015 Views

Actsip-H - Esco-da.be

Actsip-H - Esco-da.be

Actsip-H - Esco-da.be

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Actron AB Main Menu 937.9.2.4. Capacity HIFLOW (steps)"Setup-PLC-Capacity HIFLOW (steps)"You specify the amount of memory to reserve for HIFLOW programs. <strong>Actsip</strong>-Hcalculates the amount of memory left for HILADDER programs and this is shownwithin parenthesis. HILADDER memory is used by <strong>Actsip</strong>-H for ladder or instructionprogramming.7.9.2.5. I/O assignment"Setup-PLC-I/O assignment"╔═══════════════════════════════════════════════════════════════════════════╗║ Base/exp I/O Assignment┌ PgDn=More ┐║║ Points: 128 │0=DUMMY 0│║║ Slot: 0 1 2 3 4 5 6 7 8 9 A │1=DUMMY 16│║║┌─────┬────┬────┬────┬────┬────┬────┬────┬────┬────┬────┬────┐│2=DUMMY 32│║║│Unit0│ X16│ X16│ │ │ │ │ │ │ │ │ ││3=DUMMY 48│║║│ 1│ │ │ │ │ │ │ │ │ │ │ ││4=DUMMY 64│║║│ 2│ │ │ │ │ │ │ │ │ │ │ ││5=DUMMY 128│║║│ 3│ │ │ │ │ │ │ │ │ │ │ ││6=B INP X16│║║│ 4│ │ │ │ │ │ │ │ │ │ │ ││7=B INP X32│║║│ 5│ │ │ │ │ │ │ │ │ │ │ ││8=B INP X48│║║│ 6│ │ │ │ │ │ │ │ │ │ │ ││9=B INP X64│║║│ 7│ │ │ │ │ │ │ │ │ │ │ ││Q=B OUT Y16│║║│ 8│ │ │ │ │ │ │ │ │ │ │ ││W=B OUT Y32│║║│ 9│ │ │ │ │ │ │ │ │ │ │ ││E=B OUT Y48│║║└─────┴────┴────┴────┴────┴────┴────┴────┴────┴────┴────┴────┘│R=B OUT Y64│║║ SPACE = Toggle Stan<strong>da</strong>rd/Remote│T=W INP X4W│║║ Arrows = Move│Y=W INP X8W│║║ Num<strong>be</strong>rs= Select module│U=W OUT Y4W│║║ INS = Copy real assignment │I=W OUT Y8W│║║ ESCAPE = Leave└───────────┘║║║╚═══════════════════════════════════════════════════════════════════════════╝This functions assigns modules to slots. Use the arrow keys to position the cursor onthe desired slot and select a module from the help window by pressing thecorresponding digit or letter. and toggles the help window <strong>be</strong>tween the two sets of modules.Remove a module by selecting the "DUMMY 0" module (code 0) or "DUMMY 16"for smaller H series. The module assignment table is transferred to PLC together withthe project and is also used during editing to check and reject addresses that are notassigned.HINT!exits the I/O monitor menu.toggles <strong>be</strong>tween base/expansion and remote I/O 1 to 4. Specialfunction modules such as LINK-H and COMM-H can only <strong>be</strong>assigned to the base unit.Copy real assignment from the PLC.The help screen (available with the key) shows a list of variousmodules and their corresponding assignment code.Copyright Actron AB, 1992

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!