PLATED TRUSSINSTALLATION GUIDEGENERAL NOTESThis installation guide lists the most common <strong>USP</strong> plated trussinstallations. Refer to <strong>USP</strong>’s current Full Line Catalog for detailedhanger information and additional installation options. Consult theplated truss fabricator for information concerning the use of theirproducts. <strong>USP</strong> Structural <strong>Connectors</strong> ® does not express, and willnot accept, responsibility for any wood component including, butnot limited to, bearing blocks and backing blocks.Use proper safety equipment during connector installations.Always wear gloves when handling connectors.The type and quantity of fasteners used to install <strong>USP</strong> products iscritical to connector performance. To achieve the allowable loads,NA NAI Linstall with the fasteners specified.Drill bolt holes a minimum of 1⁄ 32˝ and a maximum of 1⁄ 16˝ largerthan the diameter of the bolt to be installed (per the 2005 NDS ® ,Section 11.1.2).NAILS<strong>USP</strong> Wire NailStock No. 2 Ref. No. Description Finish 1 Gauge Diameter LengthNA11 N8 8d x 1-1/2 HDG -- -- 0.131 1-1/2NA8D N8 8d x 1-1/2 HDG -- -- 0.131 1-1/2-- -- -- -- 8d Common Bright 10-1/4 ga. 0.131 2-1/2NA9D N10 10d x 1-1/2 HDG -- -- 0.148 1-1/2NA10D N10 10d x 1-1/2 HDG -- -- 0.148 1-1/2N10C 10DHDG 10d Common HDG -- -- 0.148 3-- -- -- -- 10d Common Bright 9 ga. 0.148 3-- -- -- -- 16d Sinker Bright 9 ga. 0.148 3-1/4NA16D N16 16d x 2-1/2 HDG -- -- 0.162 2-1/2N16C 16DHDG 16d Common HDG -- -- 0.162 3-1/2-- -- -- -- 16d Common Bright 8 ga. 0.162 3-1/21) HDG = Hot-Dip Galvanized; Bright = No Finish2) Bright finish common and sinker nails are listed in table for reference only.<strong>USP</strong> does not stock these type nails.WOOD SCREW<strong>USP</strong>DimensionsStock No. Ref. No. Description Finish 1 L SH TWS3 SDS25300 Washers should always be used under the head of a bolt or nut ofa bolt when not in contact with the connector, unless notedotherwise.It is permissible to use nail guns to install connectors, provided thespecified nails are installed through prepunched nail holes and allspecified nail holes are filled. Refer to <strong>USP</strong> Technical Bulletins;<strong>USP</strong>829 – Halsteel, <strong>USP</strong>812 – Paslode, and <strong>USP</strong>814 – Senco, forspecific instructions. <strong>USP</strong> recommends the use of nail gunsfeaturing hole-locating mechanisms. Please note that many nailguns use fasteners smaller than common size and load reductionswill result. Caution: Always follow nail gun manufacturer’s safetyguidelines.Joists installed in hangers shall bear fully on the connector seatand shall be cut to fit against the header with a gap no greaterthan 1⁄ 8˝ between the joist end and header face.Multiple ply members must be fastened securely together to act asone unit.NA11/NA8D.131 x 1-1/2”<strong>USP</strong> nameCODES:ESR-2761,FL13170NA9D/NA10D.148 x 1-1/2”Screw lengthN10C.148 x 3”LSHNA16D N16C.162 x 2-1/2” .162 x 3-1/2”SerrationsBeveled reamerTCut threads3/8˝Self drilling point1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


HUS410 & THD410 HANGERSFLOOR TRUSS HANGERSMSH SERIES ADJUSTABLE STRAP HANGERSFastener Schedule 3Carrying Member CarriedCarried <strong>USP</strong> Header MemberMember Stock No. Ref. No. Top Face <strong>Truss</strong>Maximum Nailing 11 Ply MSH418 THA418 -- -- (18) 10d (6) 10dMSH422 THA422 -- -- (22) 10d (6) 10dMSH422IF THAC422 -- -- (22) 10d (4) 10d2 PlyMSH422-2 THA422-2 -- -- (26) 16d (6) 16dMSH422-2IF THAC422-2 -- -- (26) 16d (6) 16dMinimum Nailing 2MSH418 THA418 (4) 10d (2) 10d (6) 10d1 PlyMSH422 THA422 (4) 10d (2) 10d (6) 10dMSH422IF HUS THAC422 (4) 10d (2) 10d (4) 10dMSH426 THA426 (4) 16d (2) 16d (6) 16d2 PlyMSH422-2 THA422-2 (4) 16d (4) 16d (6) 16dMSH422-2IF THAC422-2 (4) 16d (4) 16d (6) 16d1) Maximum Nailing - All face nails must be used. Double shear nailingrequired through the truss into header for applicable models.2) Minimum Nailing - The hanger is installed in a top mount conditionwith at least the top two header face nail holes filled, and four topflange nail holes filled. The strap must wrap over the top at least 2"and the joist nails shall be installed straight into the joist3) 10d nails are 0.148" diameter x 3" long and 16d nails are0.162" diameter x 3-1/2" long.Some model designs mayvary from illustrations shownFastener Schedule 1Carrying Carried<strong>USP</strong> Member MemberStock No. Ref. No. Header <strong>Truss</strong>HUS410 HUS410 (8) 16d (8) 16dTHD410 HHUS410 (38) 16d (20) 10d1) 10d nails are 0.148" diameter x 3" long and16d nails are 0.162" diameter x 3-1/2" long.CODES:ESR-1781ESR-1881FL 13285FL 821L.A. City RR 25843L.A. City RR 25779Dade County FL 06-0921.05CODES:ESR-1831FL822L.A. City RR 25836Dade County, FL 08-0303.06Typical MSH422-2IF installationTop Mount MinimumMSH422THD410Drive joistnails intoheader ata 30° to45° angle.Raised dimpleallows 30° to 45°nailingDouble shearnail designfeaturesfewer nailsand fasterinstallation.HUS4101-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


TRUSS TO WALL CONNECTORSTR SERIES ROOF TRUSS TIES<strong>USP</strong> Fastener Schedule 1Stock No. Ref. No. <strong>Truss</strong> PlateTR1 STC (1) 8d (2) 8dTR2 DTC (2) 8d (4) 8d1) 8d nails are 0.131" diameter x 2-1/2" long.1 1 /2˝ slots allow for truss float. Do Not fullyseat nails into truss when installing. Locatenails into the center of slots.Typical T R2 installationT R2(TR1 similar)STC SERIES SCISSORS TRUSS CLIPSCODES:ESR-1465FL817Wall <strong>USP</strong> Fastener Schedule 1Width Stock No. Ref. No. <strong>Truss</strong> Plate2 x 4 STC24 TC24 (6) 10d x 1-1/2 (5) 10d x 1-1/22 x 6 STC26 TC26 (5) 10d x 1-1/2 (5) 10d x 1-1/22 x 8 STC28 TC28 (5) 10d x 1-1/2 (5) 10d x 1-1/21) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long.Typical STC24installationSTC2411/2˝ slots allow for truss float. Do Not fullyseat nails into truss when installing. Locatenails into the center of slots.SBP SERIES SUPPLEMENTARY BEARING PLATESSBP4CODES:ESR-1831FL822L.A. City RR 25836Fastener Schedule 1,2Wall <strong>USP</strong> Joist PlateWidth Stock No. Ref. No. Thickness 3 Top Sides <strong>Truss</strong>2 x 42 x 6SBP4SBP6TBE4TBE6(4) 10d(4) 10d(8) 10d(8) 10d(20) 10dx1-1/2(28) 10dx1-1/2(4) 10d(4) 10d(8) 10d(8) 10d(20) 10d(28) 10d1) Fastener Schedule is for a pair of SBP devices.3) Multiple ply trusses shall be fastened together to act as a single unit.Typical SBP4installation1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


GIRDER TRUSS HANGERSGT SERIES GIRDER TRUSS HANGERSTypical GT2T4BinstallationCODES:ESR-1831FL822L.A. City RR 25836Fastener Schedule 1,2Carrying Carried MinimumCarried <strong>USP</strong> Member Member VerticalMember Stock No. Ref. No. Bolts Nails MemberGT2T2B -- -- (2) 3/4 (12) 16d 2 x 6GT2T2BH -- -- (2) 1 (12) 16d 2 x 62 PlyGT2T3B -- -- (3) 3/4 (12) 16d 2 x 6GT2T4B THGB2 (4) 3/4 (12) 16d 2 x 8GT2T6B -- -- (6) 3/4 (12) 16d 2 x 8GT2T8B THGBH2 (8) 3/4 (12) 16d 2 x 8GT3T3B -- -- (3) 3/4 (12) 16d 2 x 6GT3T3BH -- -- (3) 1 (12) 16d 2 x 63 PlyGT3T4B THGB3 (4) 3/4 (12) 16d 2 x 8GT3T4BH -- -- (4) 1 (12) 16d 2 x 8GT3T6B -- -- (6) 3/4 (12) 16d 2 x 8GT3T8B THGBH3 (8) 3/4 (12) 16d 2 x 8GT4T4B -- -- (4) 3/4 (12) 16d 2 x 8GT4T4BH -- -- (4) 1 (12) 16d 2 x 84 Ply GT4T6B -- -- (6) 3/4 (12) 16d 2 x 8GT4T6BH -- -- (6) 1 (12) 16d 2 x 8GT4T8B THGBH4 (8) 3/4 (12) 16d 2 x 85 Ply GT5T8BH -- -- (8) 1 (12) 16d 2 x 81) Bolts shall conform to ASTM A 307 Grade A or better.2) 16d nails are 0.162" diameter x 3-1/2" long.GT2T4BGTWS SERIES HIGH UPLIFT GIRDER TRUSS HANGERSCODES:FL6223Fastener Schedule 1Carrying Carried MinimumCarried <strong>USP</strong> Member Member VerticalMember Stock No. Ref. No. Wood Screws Wood Screws Member2 Ply GTWS2T -- -- (22) WS3 (16) WS3 2 x 63 Ply GTWS3T -- -- (28) WS3 (24) WS3 2 x 84 Ply GTWS4T -- -- (28) WS3 (24) WS3 2 x 10GTWS hangers.Typical GTWS2TinstallationGTWS2T1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


nsHGA & HGAMTRUSS TO TRUSS HANGERSJUS, THD, & THDH HANGERSFastener Schedule 1Carrying CarriedCarried <strong>USP</strong> Member MemberMember Stock No. Ref. No. Header <strong>Truss</strong>JUS24 LUS24 (4) 10d (2) 10dJUS26 LUS26 (4) 10d (4) 10dJUS28 LUS28 (6) 10d (4) 10d1 Ply JUS210 LUS210 (8) 10d (4) 10dTHD26 HTU26 (18) 16d (12) 10d x 1-1/2THD28 HTU28 (28) 16d (16) 10d x 1-1/2THD210 HTU210 (38) 16d (20) 10d x 1-1/2THD26-2 HHUS26-2, HTU26-2 (18) 16d (12) 10dTHD28-2 HHUS28-2, HTU28-2 (28) 16d (16) 10d2 PlyTHD210-2 HHUS210-2, HTU210-2 (38) 16d (20) 10dTHDH26-2 2 HGUS26-2 (20) 16d (8) 16dTHDH28-2 2 HGUS28-2 (36) 16d (10) 16dTHDH210-2 2 HGUS210-2 (46) 16d (12) 16dTHDH26-3 HGUS26-3 (20) 16d (8) 16d3 Ply THDH28-3 HGUS28-3 (36) 16d (12) 16dTHDH210-3 HGUS210-3 (46) 16d (16) 16d1) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long, 10d nails are 0.148"diameter x 3" long, 16d nails are 0.162" diameter x 3-1/2" long, and 16d sinkers2) Drive bend line nails into header at a 30° to 45° angle.CODES:ESR-1781ESR-1881FL13285FL821L.A. City RR 25779L.A. City RR 25843Dade County,FL 06-0921.05Dade County,FL 11-0510.01Drive joist nailsinto header at a30° to 45°angle.Typical JUS26 installationDouble shearnail designfeaturesfewer nailsand fasterinstallation.Raised dimpleallows 45° nailingPage 1THD28 THDH26-2 JUS28Some model designs mayvary from illustration shown1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


SKH & SKHHTRUSS TO TRUSS CONNECTORSMSH29 ADJUSTABLE STRAP HANGERFastener Schedule 1Carrying Member Carried<strong>USP</strong> Header MemberStock No. Ref. No. Top Face <strong>Truss</strong>Maximum Nailing 2MSH29 THA29-- -- (18) 10d (4) 10dMinimum Nailing 3(4) 10d (2) 10d (4) 10d x 1-1/21) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long, 10dnails are 0.148" diameter x 3" long, and 16d sinkers are10d commons are specified.2) Maximum Nailing - All face nails must be used. Doubleshear nailing required through the truss into header.3) Minimum Nailing - The hanger is installed in a top mountcondition with at least the top two header face nail holesfilled, and four top flange nail holes filled. The strap mustwrap over the top at least 2" and the joist nails shall beinstalled straight into the joistSKH & SKHH SERIES SKEWED 45° HANGERSFastener Schedule 1,2Carrying CarriedCarried <strong>USP</strong> Member MemberMember Stock No. Ref. No. Header <strong>Truss</strong>SKH24L/R SUR/L24 (4) 16d (4) 10d x 1-1/21 PlySKH26L/R SUR/L26 (6) 16d (6) 10d x 1-1/2SKH28L/R -- -- (10) 16d (8) 10d x 1-1/2SKH210L/R SUR/L210 (14) 16d (10) 10d x 1-1/22 PlySKHH26L/R-2 HSUR/L26-2 (12) 16d (4) 16d x 2-1/2SKHH210L/R-2 HSUR/L210-2 (20) 16d (6) 16d x 2-1/21) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long, 16d x 2-1/2 nails areSNP3 SKEWED NAIL PLATE<strong>USP</strong>Fastener ScheduleStock No. Ref. No. Each EndSNP3 TJC37 (6) 8d x 1-1/21) 8d x 1-1/2 nails are 0.131" diameter x 1-1/2" long.1CODES:ESR-2104FL820L.A. City RR 25745Bend angle only onceCODES:ESR-1831FL822L.A. City RR 25836Dade County,FL08-0303.06Drive joistnails intoheaderat a 30° to45° angle.CODES:ESR-1781FL13285L.A. City RR 25843Dade County,FL 11-0510.01SNP3Doubleshear naildesignfeatures fewernails andfasterinstallation.Right skew3 1 /2˝Typical combinationMSH29 installationRaised dimpleallows 30° to 45°nailingMSH29SKHH210R-2SKH similarSlant nailingLeft skewSupporting <strong>Truss</strong>3 1 /2˝Supported <strong>Truss</strong>45° to 90° max1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


HIP/JACK CONNECTORSHHC, HJC, HJHC, & HTHJ SERIESTypical HJC28installationCODES:ESR-1465FL817Dade County,FL 11-0510.01Fastener Schedule 1<strong>USP</strong> Carrying Carried MemberStock No. Ref. No. Member per Hip per JackHJC26 THJA26, THJU26 (16) 16d (5) 10d (7) 10dHJC28 -- -- (20) 16d (6) 10d (8) 10dHTHJ26-18 LTHJR/L (16) 16d (7) 16d (5) 16dHHC26 LTHJA26 (20) 16d (5) 10d -- --HHC28 -- -- (24) 16d (6) 10d -- --HJHC26 MTHM (20) 16d (5) 10d (2) 10dHJHC28 -- -- (24) 16d (6) 10d (2) 10d1) 10d nails are 0.148" diameter x 3" long, 16d nails are0.162" diameter x 3-1/2" long, and 16d sinkerswhere 10d commons are specified.HJC2845° 45°Typical HJC/HTHJ installation top viewHTHJ26-18HHC2645° 45°Typical HHC installation top view45º 45ºTypical HJHCinstallation top viewHJHC281-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


ALTERNATIVE INSTALLATIONSGENERAL BLOCKING NOTESWood blockingBacker block installationWood blocking used toachieve full design loadvalue of a face mounthanger attached to acarrying member.(Blocking to be designedby truss designer orengineer of record)• Wood blocking should be of similar size/grade asthe truss member to which it is attached.• The blocking should be designed to act as one unitwith truss members.• <strong>Truss</strong> designer shall approve blocking size/grade,fasteners required, and application.• All fasteners used to attach wood blocking shouldbe independent of the fasteners in the truss hanger.JUS26ALTERNATE DESIGN FOR SLOPED BOTTOM CHORD TRUSSESPanel point installationConnection with face mounthanger attaching to atruss panel point. (Hanger nailsthat do not penetrate wood inpanel point provide no loadresistance) Reduce loadaccording to code.GT4T6BHTHDH28-2Filler blockingFiller block installationWood filler blocking used forsupported member width lessthan hanger width.(Blocking and blocking fasteners/quantity to be designed by trussdesigner or engineer of record.)Rise/RunWeb &setbackUpset2 Ply GirderThis alternate design for slopedbottom chord trusses demonstratesthe use of end-vertical upset to allowfor the use of non-sloped hangers.Upset = Rise/Run x (Web + Setback)This procedure will work with commonstandard hangers as well as terminalhangers such as <strong>USP</strong>’s HJC, HHC,and HJHC series. Designer shouldreview the D-dimension on the hangerto confirm the flat area on the verticalis sufficient for full bearing.<strong>Truss</strong> designer shall be responsible forall truss design issues, including butnot limited to plate shear and trussbearing.Rise / Run Vertical Upset(inches) Web (inches)1/122/123/124/125/126/127/128/129/1210/1211/1212/122 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 45/165/87/81-3/161-1/21-3/42-1/162-3/82-5/82-15/163-1/43-1/22 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 61/215/161-3/81-7/82-5/162-3/43-1/43-11/164-1/84-5/85-1/165-1/21-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


HUS410 & THD410 HANGERSFLOOR TRUSS HANGERSMSH SERIES ADJUSTABLE STRAP HANGERSFastener Schedule 3Carrying Member CarriedCarried <strong>USP</strong> Header MemberMember Stock No. Ref. No. Top Face <strong>Truss</strong>Maximum Nailing 11 Ply MSH418 THA418 -- -- (18) 10d (6) 10dMSH422 THA422 -- -- (22) 10d (6) 10dMSH422IF THAC422 -- -- (22) 10d (4) 10d2 PlyMSH422-2 THA422-2 -- -- (26) 16d (6) 16dMSH422-2IF THAC422-2 -- -- (26) 16d (6) 16dMinimum Nailing 2MSH418 THA418 (4) 10d (2) 10d (6) 10d1 PlyMSH422 THA422 (4) 10d (2) 10d (6) 10dMSH422IF HUS THAC422 (4) 10d (2) 10d (4) 10dMSH426 THA426 (4) 16d (2) 16d (6) 16d2 PlyMSH422-2 THA422-2 (4) 16d (4) 16d (6) 16dMSH422-2IF THAC422-2 (4) 16d (4) 16d (6) 16d1) Maximum Nailing - All face nails must be used. Double shear nailingrequired through the truss into header for applicable models.2) Minimum Nailing - The hanger is installed in a top mount conditionwith at least the top two header face nail holes filled, and four topflange nail holes filled. The strap must wrap over the top at least 2"and the joist nails shall be installed straight into the joist3) 10d nails are 0.148" diameter x 3" long and 16d nails are0.162" diameter x 3-1/2" long.Fastener Schedule 1Carrying Carried<strong>USP</strong> Member MemberStock No. Ref. No. Header <strong>Truss</strong>HUS410 HUS410 (8) 16d (8) 16dTHD410 HHUS410 (38) 16d (20) 10d1) 10d nails are 0.148" diameter x 3" long and16d nails are 0.162" diameter x 3-1/2" long.Some model designs mayvary from illustrations shownCODES:ESR-1781ESR-1881FL 13285FL 821L.A. City RR 25843L.A. City RR 25779Dade County FL 06-0921.05CODES:ESR-1831FL822L.A. City RR 25836Dade County, FL 08-0303.06Typical MSH422-2IF installationTop Mount MinimumMSH422THD410Drive joistnails intoheader ata 30° to45° angle.Raised dimpleallows 30° to 45°nailingDouble shearnail designfeaturesfewer nailsand fasterinstallation.HUS4101-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


TRUSS TO WALL CONNECTORSTR SERIES ROOF TRUSS TIES<strong>USP</strong> Fastener Schedule 1Stock No. Ref. No. <strong>Truss</strong> PlateTR1 STC (1) 8d (2) 8dTR2 DTC (2) 8d (4) 8d1) 8d nails are 0.131" diameter x 2-1/2" long.1 1 /2˝ slots allow for truss float. Do Not fullyseat nails into truss when installing. Locatenails into the center of slots.Typical T R2 installationT R2(TR1 similar)STC SERIES SCISSORS TRUSS CLIPSCODES:ESR-1465FL817Wall <strong>USP</strong> Fastener Schedule 1Width Stock No. Ref. No. <strong>Truss</strong> Plate2 x 4 STC24 TC24 (6) 10d x 1-1/2 (5) 10d x 1-1/22 x 6 STC26 TC26 (5) 10d x 1-1/2 (5) 10d x 1-1/22 x 8 STC28 TC28 (5) 10d x 1-1/2 (5) 10d x 1-1/21) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long.Typical STC24installationSTC2411/2˝ slots allow for truss float. Do Not fullyseat nails into truss when installing. Locatenails into the center of slots.SBP SERIES SUPPLEMENTARY BEARING PLATESSBP4CODES:ESR-1831FL822L.A. City RR 25836Fastener Schedule 1,2Wall <strong>USP</strong> Joist PlateWidth Stock No. Ref. No. Thickness 3 Top Sides <strong>Truss</strong>2 x 42 x 6SBP4SBP6TBE4TBE6(4) 10d(4) 10d(8) 10d(8) 10d(20) 10dx1-1/2(28) 10dx1-1/2(4) 10d(4) 10d(8) 10d(8) 10d(20) 10d(28) 10d1) Fastener Schedule is for a pair of SBP devices.3) Multiple ply trusses shall be fastened together to act as a single unit.Typical SBP4installation1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


GIRDER TRUSS HANGERSGT SERIES GIRDER TRUSS HANGERSTypical GT2T4BinstallationCODES:ESR-1831FL822L.A. City RR 25836Fastener Schedule 1,2Carrying Carried MinimumCarried <strong>USP</strong> Member Member VerticalMember Stock No. Ref. No. Bolts Nails MemberGT2T2B -- -- (2) 3/4 (12) 16d 2 x 6GT2T2BH -- -- (2) 1 (12) 16d 2 x 62 PlyGT2T3B -- -- (3) 3/4 (12) 16d 2 x 6GT2T4B THGB2 (4) 3/4 (12) 16d 2 x 8GT2T6B -- -- (6) 3/4 (12) 16d 2 x 8GT2T8B THGBH2 (8) 3/4 (12) 16d 2 x 8GT3T3B -- -- (3) 3/4 (12) 16d 2 x 6GT3T3BH -- -- (3) 1 (12) 16d 2 x 63 PlyGT3T4B THGB3 (4) 3/4 (12) 16d 2 x 8GT3T4BH -- -- (4) 1 (12) 16d 2 x 8GT3T6B -- -- (6) 3/4 (12) 16d 2 x 8GT3T8B THGBH3 (8) 3/4 (12) 16d 2 x 8GT4T4B -- -- (4) 3/4 (12) 16d 2 x 8GT4T4BH -- -- (4) 1 (12) 16d 2 x 84 Ply GT4T6B -- -- (6) 3/4 (12) 16d 2 x 8GT4T6BH -- -- (6) 1 (12) 16d 2 x 8GT4T8B THGBH4 (8) 3/4 (12) 16d 2 x 85 Ply GT5T8BH -- -- (8) 1 (12) 16d 2 x 81) Bolts shall conform to ASTM A 307 Grade A or better.2) 16d nails are 0.162" diameter x 3-1/2" long.GT2T4BGTWS SERIES HIGH UPLIFT GIRDER TRUSS HANGERSCODES:FL6223Fastener Schedule 1Carrying Carried MinimumCarried <strong>USP</strong> Member Member VerticalMember Stock No. Ref. No. Wood Screws Wood Screws Member2 Ply GTWS2T -- -- (22) WS3 (16) WS3 2 x 63 Ply GTWS3T -- -- (28) WS3 (24) WS3 2 x 84 Ply GTWS4T -- -- (28) WS3 (24) WS3 2 x 10GTWS hangers.Typical GTWS2TinstallationGTWS2T1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


nsHGA & HGAMTRUSS TO TRUSS HANGERSJUS, THD, & THDH HANGERSFastener Schedule 1Carrying CarriedCarried <strong>USP</strong> Member MemberMember Stock No. Ref. No. Header <strong>Truss</strong>JUS24 LUS24 (4) 10d (2) 10dJUS26 LUS26 (4) 10d (4) 10dJUS28 LUS28 (6) 10d (4) 10d1 Ply JUS210 LUS210 (8) 10d (4) 10dTHD26 HTU26 (18) 16d (12) 10d x 1-1/2THD28 HTU28 (28) 16d (16) 10d x 1-1/2THD210 HTU210 (38) 16d (20) 10d x 1-1/2THD26-2 HHUS26-2, HTU26-2 (18) 16d (12) 10dTHD28-2 HHUS28-2, HTU28-2 (28) 16d (16) 10d2 PlyTHD210-2 HHUS210-2, HTU210-2 (38) 16d (20) 10dTHDH26-2 2 HGUS26-2 (20) 16d (8) 16dTHDH28-2 2 HGUS28-2 (36) 16d (10) 16dTHDH210-2 2 HGUS210-2 (46) 16d (12) 16dTHDH26-3 HGUS26-3 (20) 16d (8) 16d3 Ply THDH28-3 HGUS28-3 (36) 16d (12) 16dTHDH210-3 HGUS210-3 (46) 16d (16) 16d1) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long, 10d nails are 0.148"diameter x 3" long, 16d nails are 0.162" diameter x 3-1/2" long, and 16d sinkers2) Drive bend line nails into header at a 30° to 45° angle.CODES:ESR-1781ESR-1881FL13285FL821L.A. City RR 25779L.A. City RR 25843Dade County,FL 06-0921.05Dade County,FL 11-0510.01Drive joist nailsinto header at a30° to 45°angle.Typical JUS26 installationDouble shearnail designfeaturesfewer nailsand fasterinstallation.Raised dimpleallows 45° nailingPage 1THD28 THDH26-2 JUS28Some model designs mayvary from illustration shown1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


SKH & SKHHTRUSS TO TRUSS CONNECTORSMSH29 ADJUSTABLE STRAP HANGERFastener Schedule 1Carrying Member Carried<strong>USP</strong> Header MemberStock No. Ref. No. Top Face <strong>Truss</strong>Maximum Nailing 2MSH29 THA29-- -- (18) 10d (4) 10dMinimum Nailing 3(4) 10d (2) 10d (4) 10d x 1-1/21) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long, 10dnails are 0.148" diameter x 3" long, and 16d sinkers are10d commons are specified.2) Maximum Nailing - All face nails must be used. Doubleshear nailing required through the truss into header.3) Minimum Nailing - The hanger is installed in a top mountcondition with at least the top two header face nail holesfilled, and four top flange nail holes filled. The strap mustwrap over the top at least 2" and the joist nails shall beinstalled straight into the joistSKH & SKHH SERIES SKEWED 45° HANGERSFastener Schedule 1,2Carrying CarriedCarried <strong>USP</strong> Member MemberMember Stock No. Ref. No. Header <strong>Truss</strong>SKH24L/R SUR/L24 (4) 16d (4) 10d x 1-1/21 PlySKH26L/R SUR/L26 (6) 16d (6) 10d x 1-1/2SKH28L/R -- -- (10) 16d (8) 10d x 1-1/2SKH210L/R SUR/L210 (14) 16d (10) 10d x 1-1/22 PlySKHH26L/R-2 HSUR/L26-2 (12) 16d (4) 16d x 2-1/2SKHH210L/R-2 HSUR/L210-2 (20) 16d (6) 16d x 2-1/21) 10d x 1-1/2 nails are 0.148" diameter x 1-1/2" long, 16d x 2-1/2 nails areSNP3 SKEWED NAIL PLATE<strong>USP</strong>Fastener ScheduleStock No. Ref. No. Each EndSNP3 TJC37 (6) 8d x 1-1/21) 8d x 1-1/2 nails are 0.131" diameter x 1-1/2" long.1CODES:ESR-2104FL820L.A. City RR 25745Bend angle only onceCODES:ESR-1831FL822L.A. City RR 25836Dade County,FL08-0303.06Drive joistnails intoheaderat a 30° to45° angle.CODES:ESR-1781FL13285L.A. City RR 25843Dade County,FL 11-0510.01SNP3Doubleshear naildesignfeatures fewernails andfasterinstallation.Right skew3 1 /2˝Typical combinationMSH29 installationRaised dimpleallows 30° to 45°nailingMSH29SKHH210R-2SKH similarSlant nailingLeft skewSupporting <strong>Truss</strong>3 1 /2˝Supported <strong>Truss</strong>45° to 90° max1-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


HIP/JACK CONNECTORSHHC, HJC, HJHC, & HTHJ SERIESTypical HJC28installationCODES:ESR-1465FL817Dade County,FL 11-0510.01Fastener Schedule 1<strong>USP</strong> Carrying Carried MemberStock No. Ref. No. Member per Hip per JackHJC26 THJA26, THJU26 (16) 16d (5) 10d (7) 10dHJC28 -- -- (20) 16d (6) 10d (8) 10dHTHJ26-18 LTHJR/L (16) 16d (7) 16d (5) 16dHHC26 LTHJA26 (20) 16d (5) 10d -- --HHC28 -- -- (24) 16d (6) 10d -- --HJHC26 MTHM (20) 16d (5) 10d (2) 10dHJHC28 -- -- (24) 16d (6) 10d (2) 10d1) 10d nails are 0.148" diameter x 3" long, 16d nails are0.162" diameter x 3-1/2" long, and 16d sinkerswhere 10d commons are specified.HJC2845° 45°Typical HJC/HTHJ installation top viewHTHJ26-18HHC2645° 45°Typical HHC installation top view45º 45ºTypical HJHCinstallation top viewHJHC281-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121


ALTERNATIVE INSTALLATIONSGENERAL BLOCKING NOTESWood blockingBacker block installationWood blocking used toachieve full design loadvalue of a face mounthanger attached to acarrying member.(Blocking to be designedby truss designer orengineer of record)• Wood blocking should be of similar size/grade asthe truss member to which it is attached.• The blocking should be designed to act as one unitwith truss members.• <strong>Truss</strong> designer shall approve blocking size/grade,fasteners required, and application.• All fasteners used to attach wood blocking shouldbe independent of the fasteners in the truss hanger.JUS26ALTERNATE DESIGN FOR SLOPED BOTTOM CHORD TRUSSESPanel point installationConnection with face mounthanger attaching to atruss panel point. (Hanger nailsthat do not penetrate wood inpanel point provide no loadresistance) Reduce loadaccording to code.GT4T6BHTHDH28-2Filler blockingFiller block installationWood filler blocking used forsupported member width lessthan hanger width.(Blocking and blocking fasteners/quantity to be designed by trussdesigner or engineer of record.)Rise/RunWeb &setbackUpset2 Ply GirderThis alternate design for slopedbottom chord trusses demonstratesthe use of end-vertical upset to allowfor the use of non-sloped hangers.Upset = Rise/Run x (Web + Setback)This procedure will work with commonstandard hangers as well as terminalhangers such as <strong>USP</strong>’s HJC, HHC,and HJHC series. Designer shouldreview the D-dimension on the hangerto confirm the flat area on the verticalis sufficient for full bearing.<strong>Truss</strong> designer shall be responsible forall truss design issues, including butnot limited to plate shear and trussbearing.Rise / Run Vertical Upset(inches) Web (inches)1/122/123/124/125/126/127/128/129/1210/1211/1212/122 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 42 x 45/165/87/81-3/161-1/21-3/42-1/162-3/82-5/82-15/163-1/43-1/22 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 62 x 61/215/161-3/81-7/82-5/162-3/43-1/43-11/164-1/84-5/85-1/165-1/21-800-328-5934/1-952-898-8772 www.<strong>USP</strong>connectors.com info@uspconnectors.com© Copyright 2012 United Steel Products Company <strong>USP</strong>844-121