13.07.2015 Views

Specification Bulletin 682-31 - S&C Electric Company

Specification Bulletin 682-31 - S&C Electric Company

Specification Bulletin 682-31 - S&C Electric Company

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

S&C Remote Supervisory Vista® Underground Distribution SwitchgearConditions of Sale—ContinuedCoordinating-speed curves have phase-overcurrentand—for three-pole tripping fault interrupters only—ground-overcurrent settings. (The latter can be turned offif desired.) These curves can be tailored to the applicationusing a variety of instantaneous and definite-time settings.UnderCover StyleWhen the UnderCover Style is specified, a stainless-steeltank with submersible wiring is furnished suitable forunderground installation. A mild-steel or, optionally,stainless-steel low-voltage enclosure is mounted on acustomer-supplied pad at grade level. It is connected to thetank with cabling up to 45 feet in length.Vault-Mounted StyleTwo versions of this style are available: Wet-Vault-MountedStyle is intended for vaults that are subject to periodicflooding and includes submersible wiring and electricalcomponents. Dry-Vault-Mounted Style is intended for vaultsthat are not subject to periodic flooding and does not includesubmersible wiring and electrical components.When the Wet-Vault-Mounted Style is specified, astainless-steel tank is furnished, suitable for mounting on thefloor or wall of a vault. When the Dry-Vault-Mounted Style isspecified, a mild-steel tank is furnished. The mild-steel or,optionally, stainless-steel low-voltage enclosure is mountedon the vault floor or wall; it is connected to the tank withcabling up to 45 feet in length.Pad-Mounted StyleWhen the Pad-Mounted Style is specified, a mild-steel or,optionally, stainless-steel enclosure is furnished. A mild-steelor, optionally, stainless-steel low-voltage compartment ismounted on the side of the enclosure.Although the Vista UDS tank itself is submersible, manyof the electrical components mounted to the tank are not.Special submersible components and wiring are providedwhen the UnderCover Style or Wet-Vault-Mounted Styleis specified. Contact your nearest S&C Sales Office forinformation on Pad-Mounted Style units with submersiblewiring.Pad-mounted enclosures meet the requirements ofANSI Standard C57.12.28 for enclosure integrity. The topof the enclosure is hinged on both sides for convenientaccess to the operating and termination compartments.A removable panel provides access to the elbows andcables and is secured by the overlapping padlockable top.A resilient closed-cell gasket on the enclosure bottomflange protects the finish from being scratched duringinstallation and isolates it from the alkalinity of a concretefoundation. Enclosures are protected from corrosion byS&C’s Ultradur® Finishing System.Motor Operators and SensingMotor operators provide the basis for automation. Therobust Vista motor operator is available factory-installed orit can be readily installed in the field. It is easily removedfor testing of the communication and control equipmentwithout actually operating the gear.Three-phase voltage sensing and three-phase currentsensing are available for motor operated ways.Low-Voltage Compartment EnclosureMotor operator controls are located within the low-voltagecompartment. Each motor operator is provided witha control board which includes “Close,” “Open,” and,optionally, “Ground” push buttons; switch-positionindicating lamps; operation counter; lamp test button;and receptacle for portable remote control station. Up tosix control boards can be accommodated, so any or allload-interrupter switches or three-pole fault interrupterways may be motor operated. A single “Local/Remote”switch is provided for all control boards, permitting anon-site operator to take complete control of the gear.A 36-volt, 5-ampere-hour, rechargeable, sealed-starvedelectrolytelead battery pack and 80-watt temperaturecompensatedoutput battery charger are also furnished inthe low-voltage compartment. The battery charger featuresintegral load-disconnect circuitry to prevent deep-dischargeof batteries on loss of ac source; alarms for loss of ac source,battery low voltage, and charger overvoltage; and a remoteor locally initiated battery test function. It provides both36-Vdc and 12-Vdc outputs. The battery charger requiresa 120-Vac, 50/60-Hz or 240-Vac, 50/60-Hz external powersupply; internal control power is optionally available.Connections are provided for the external power input;“close,” “open,” and, optionally, “ground” command inputs;switch-position indication; current- and voltage-sensoroutputs; and battery-test and battery-status outputs.Communication and Control EquipmentA user-specified remote terminal unit (RTU) and communicationdevice may be furnished in the low-voltagecompartment, providing a completely automated distributionswitching and protection package. Contact yournearest S&C Sales Office for details. Alternately, a controlunit for use with RTU by others or a control unit for usewithout RTU may be furnished. One of these three controlequipment packages must be specified when ordering. Seethe table on page 11.2 S&C <strong>Specification</strong> <strong>Bulletin</strong> <strong>682</strong>-<strong>31</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!