ETransferring Hydrometer Readings from the DMA-35 Hydrometeri. Transferring hydrometer datainto a string location erasesALL existing data.ii. This process cannot beundone.1. To initiate data transfer fromthe DMA-35 hydrometer tothe <strong>CVR+</strong>, on the DMA-35hydrometer, select MENU,press OK, select Export, thenpress OK.2. On the <strong>CVR+</strong>, select HYD Modefrom the MAIN MENU.The <strong>CVR+</strong> displays HYD stringsA thru H with the number ofstored readings and the datewhen last reading was added.3. Select an HYD string (A-H).The stored string hydrometerdata and the date and timedata which was transferred aredisplayed.4. Line up the IRDA ports of the<strong>CVR+</strong> and DMA-35 (About 6 to12 inches apart).5. On the <strong>CVR+</strong>, press MENU andselect Upload New from thesubmenu.The DMA-35 data transferswithin 10 to 40 seconds.


FTransferring Hydrometer Readingsfrom the DMA-35N Data Logging Modulei. Transferring hydrometer datainto a string location erasesALL existing data.ii. This process cannot beundone.1. Select HYD Mode from theMAIN MENU.<strong>CVR+</strong> displays HYD strings Athru H with the number of storedreadings and the date when thelast reading was added.2. Select an HYD string (A-H).The stored string hydrometerdata and the date and timedata which was transferred aredisplayed.3. Connect the DMA-35N datalogging module to the <strong>CVR+</strong>using the supplied RS-232cable.4. On the DMA-35N data loggingmodule, select a channel (A-H)of data to transfer.5. On the <strong>CVR+</strong>, press MENU andselect Upload New from thesubmenu.The DMA-35 data transferswithin 10 to 40 seconds.!Never leave the RS232 cableconnected when measuringvoltage.RS232 Connector


GExporting One String of Stored Data to a USB Flash Drive1. Select VDC Mode or HYD Modefrom the MAIN MENU.The <strong>CVR+</strong> displays VDC or HYDstrings A thru H with the numberof stored readings and the datewhen the last reading added.2. Select a string (A-H) to export.3. Connect a USB flash drive to the<strong>CVR+</strong> using the supplied USBadapter cable (USB mini-A maleto USB female).4. Press MENU and select-> Flash USB from thesubmenu.The <strong>CVR+</strong> creates and exportsa .cdf file (cell data file) for theselected string.iv. The file name suffix _00increments if a second stringof the same base name isexported on the same date.v. NO data is deleted fromthe <strong>CVR+</strong> during the exportprocess.vi. The <strong>CVR+</strong> is configured toonly create .cdf files on a USBflash drive. It cannot delete oroverwrite existing files.!Never leave the USB flashdrive connected whenmeasuring voltage.i. The created file and locationfor the stored file (for exampleVDC String A) will be: [Root]\CVR_PLUS\mm_dd_yy\VDC_A_00.cdfii. If the “CVR_PLUS” folder orthe mm_dd_yy folder doesnot exist, the <strong>CVR+</strong> creates it.iii. mm_dd_yy refers to the datethe file was exported.


HExporting ALL Stored Data to USB Flash Drive1. Select Export All from the MAINMENU.2. Connect the USB flash drive tothe <strong>CVR+</strong> using the suppliedUSB adapter cable (USB mini-Amale to USB female).3. Press YES.The <strong>CVR+</strong> creates and exportsa .cdf file for all strings.vi. The <strong>CVR+</strong> is configured toONLY create .cdf files on a USBflash drive. It cannot delete oroverwrite existing files.!Never leave the USB flashdrive connected whenmeasuring voltage.i. The created file and locationfor each stored file (forexample VDC String A) willbe: [Root]\CVR_PLUS\mm_dd_yy\VDC_A_00.cdfii. If the “CVR_PLUS” folder orthe mm_dd_yy folder doesnot exist, the <strong>CVR+</strong> creates it.iii. ‌mm_dd_yy refers to the datethe file was exported.iv. The file name suffix _00increments if a second stringof the same base name isexported on the same date.v. NO data is deleted fromthe <strong>CVR+</strong> during the exportprocess.


Basic Instructions (Continued)JDeleting ALL StoredData from the <strong>CVR+</strong>1. Select Delete ALL from theMAIN MENU.2. Press YES.The <strong>CVR+</strong> deletes all storedVDC and HYD string data.i. This process cannot beundone.ii. Threshold limits are not resetwhen string data is deleted.KDeleting VDC Datafor One String1. Select VDC Mode.2. Select a VDC string (A-H).3. To erase existing VDC stringdata, press MENU and DeleteString.4. Press YES.The <strong>CVR+</strong> deletes all storedVDC string data.LDeleting HYD Datafor One String1. Select HYD Mode.2. Select an HYD string (A-H).3. To erase existing HYD stringdata, press MENU and DeleteString.This process cannot be undone.4. Press YES.The <strong>CVR+</strong> deletes all storedHYD string data.This process cannot be undone.


Graphical and Statistical AnalysisMReset ALL Threshold Limits1. Select Reset Limits from theMAIN MENU.2. Press YES.The <strong>CVR+</strong> resets all thresholdlimits for ALL strings (voltage,SG and temperature).This process cannot be undone.Graphical and Statistical Analysis


1. Select VDC Mode or HYD Modefrom the MAIN MENU.The <strong>CVR+</strong> displays VDC orHYD strings A thru H with thenumber of stored readings andthe date when the last readingwas added.2. Select a string (A-H).3. Press MENU and selectStatistics from the submenu.The <strong>CVR+</strong> displays statistics forthe selected string data.ODisplay String Data Statistics


1. Select VDC Mode or HYD Modefrom the MAIN MENU.The <strong>CVR+</strong> displays VDC orHYD strings A thru H with thenumber of stored readings andthe date when the last readingwas added.2. Select a string (A-H).3. Press MENU and select Graphfrom the submenu.The <strong>CVR+</strong> displays the graphfor the selected string data.PDisplay String Data Graphsi. If the threshold limits areenabled for the selectedstring, the out of tolerancereadings display in RED (high)or BLUE (low).ii. If in HYD mode, press SG/Tto toggle between the SG andTemperature graphs.iii. To move the cursor, press theUP and DOWN buttons.iv. The cursor automaticallypages up or down if more than24 readings are displayed.v. The <strong>CVR+</strong> is best heldsideways in Graph mode.


<strong>Alber</strong>corp3103 N. Andrews AvenuePompano Beach, FL 33064Technical Support770-433-8551Sales Support954-623-6660Fax954-623-6671www.alber.com4200-095Document Revision 1.00