13.07.2015 Views

Varian Saturn 2000 ion-trap GC-MS - Cromlab

Varian Saturn 2000 ion-trap GC-MS - Cromlab

Varian Saturn 2000 ion-trap GC-MS - Cromlab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.sge.comACTIVE FILM Multiplier<strong>Varian</strong> <strong>Saturn</strong> <strong>2000</strong><strong>ion</strong>-<strong>trap</strong> <strong>GC</strong>-<strong>MS</strong>The ACTIVE FILM Multipliers for the <strong>Varian</strong> <strong>Saturn</strong> <strong>2000</strong> <strong>ion</strong>-<strong>trap</strong> massspectrometer is specifically designed for this instrument. It is a direct "plug-in"replacement electron multiplier and is fully compatible with <strong>Varian</strong> hardware and"Multiplier Setup" software.PRODUCT DATAACTIVE FILM Multipliers are a new development in multiplier technology thatincorporate totally air-stable "ACTIVE FILM" materials into a discrete-dynodemultiplier design to produce an except<strong>ion</strong>ally sensitive <strong>ion</strong> detector with longoperating life and excellent air stability. ACTIVE FILM Multipliers give acombinat<strong>ion</strong> of performance and durability unsurpassed by any other type ofelectron multiplier detector.ACTIVE FILM Multipliers have higher gain than alternative multipliersresulting in consistently lower multiplier voltages. Their long operating lifetimemeans less frequent multiplier replacement and reduced instrument down-time.ELECTRON MULTIPLIER FOR VARIAN SATURN <strong>2000</strong>• “Plug-in”Compatible• High Sensitivity• Low Noise• High Gain• Long Life• Stable in airACTIVE FILM MultipliersArrive ready to install in your<strong>Varian</strong> <strong>Saturn</strong> <strong>2000</strong> <strong>ion</strong>-<strong>trap</strong> mass spectrometer


ACTIVE FILM TECHNOLOGYACTIVE FILM Multipliers are a new type of electron multiplier detector for mass spectrometry and representthe latest development in electron multiplier technology.ACTIVE FILM Multipliers combine the wide dynamic range and longevity of discrete-dynode multipliers, withthe compact size and air stability of continuous-dynode multipliers.ACTIVE FILM Multipliers are completely air-stable while exhibiting extremely wide dynamic range, longoperat<strong>ion</strong>al life, and very high sensitivity.SPECIFICATIONS Part No. 14147Replacement multiplier for <strong>Varian</strong>Mass Spectrometer model number:Typical voltage to achieve 1x10 5 gainMaximum Dark Current at 2.5kV<strong>Saturn</strong> <strong>2000</strong> <strong>GC</strong>-<strong>MS</strong>1.35 kV

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!