Available surfaces: SLActive and SLA ®<br />
straumann implants are manufactured from pure biocompatible titanium. all of <strong>the</strong><br />
implants are available with <strong>the</strong> sLactive und sLa ® surface. Both surfaces have <strong>the</strong><br />
same scientifically documented micro- and macro topography. compared to sLa ® ,<br />
sLactive exibits an additi<strong>on</strong>al chemical activity as well as hydrophilic qualities.<br />
c<strong>on</strong>sequently, healing time is reduced from 6 – 8 weeks to 3 – 4 weeks*.<br />
if <strong>the</strong> implants are inserted up to <strong>the</strong> margin of <strong>the</strong> sLactive/sLa ® surface, <strong>the</strong> smooth<br />
1.8 mm and 2.8 mm neck secti<strong>on</strong>s take <strong>the</strong> biological width into c<strong>on</strong>siderati<strong>on</strong>.<br />
<strong>the</strong> standard Plus implant with an endosteal diameter of 3.3 mm and shoulder<br />
diameter of 3.5 mm (narrow neck) has a special feature. in order to achieve optimal<br />
stability, this implant type has an external octag<strong>on</strong>.<br />
The selecti<strong>on</strong> of <strong>the</strong> suitable implant type, diameter and length must be<br />
made according to each case. In general, <strong>the</strong> dimensi<strong>on</strong>s of <strong>the</strong> tooth being<br />
replaced and/or <strong>the</strong> c<strong>on</strong>tralateral tooth should be used as a guide.<br />
*See page 50, Healing phase and immediate treatment<br />
Color coding in <strong>the</strong> <strong>Straumann</strong> ® Dental Implant System<br />
in order to simplify identificati<strong>on</strong> of <strong>the</strong> implant diameter,<br />
<strong>the</strong> ampoule lids are color coded according to <strong>the</strong> endosteal diameter:<br />
SP<br />
Ø 3.3 NN<br />
8<br />
Color coding according to <strong>the</strong> endosteal diameter<br />
SP<br />
Ø 4.1 RN<br />
SLActive<br />
10<br />
TE<br />
Ø 4.8 WN<br />
SLActive<br />
12<br />
Ø 3.3 mm Ø 4.1 mm<br />
Ø 4.8 mm<br />
a detailed presentati<strong>on</strong> of <strong>the</strong> manufacturing methods for <strong>the</strong> corresp<strong>on</strong>ding parts is<br />
given in <strong>the</strong> brochure “Pros<strong>the</strong>tic opti<strong>on</strong>s for narrow neck implants”,<br />
art. no. 152.305.