6. imPLantati<strong>on</strong><br />

Ampoules<br />

SLActive/SLA ® Ampoule<br />

straumann implants are supplied in<br />

ampoules.<br />

<strong>the</strong> blister of sLactive guarantees its<br />

sterility.<br />

<strong>the</strong> sterile ampoule of sLa ®<br />

p<br />

p<br />

guarantees its sterility.<br />

p a premounted transfer part makes<br />

it easier to remove and handle <strong>the</strong><br />

implant.<br />

Transfer part<br />

<strong>the</strong> handling of transfer aids in <strong>the</strong><br />

sLactive und sLa ® implant holder are<br />

<strong>the</strong> same for all independent of color.<br />

<strong>the</strong> transfer part c<strong>on</strong>sists of <strong>the</strong><br />

following parts:<br />

p holding screw<br />

p ring<br />

p hexag<strong>on</strong><br />

if an implant is screwed correctly into a correctly prepared implant bed, <strong>the</strong> maximum<br />

force acting <strong>on</strong> <strong>the</strong> transfer part is about 35 ncm. to avoid b<strong>on</strong>e damage (b<strong>on</strong>e<br />

necrosis or b<strong>on</strong>e splitting) in <strong>the</strong> event of incorrect use (e.g., excessive tightening<br />

resistance with an inadequate drilling depth), <strong>the</strong> transfer part is provided with a<br />

breaking point (break at about 100 ncm). if <strong>the</strong> transfer part breaks during <strong>the</strong> tightening<br />

process, part of <strong>the</strong> transfer screw remains in <strong>the</strong> adapter and <strong>the</strong> o<strong>the</strong>r part in<br />

<strong>the</strong> implant. <strong>the</strong> part in <strong>the</strong> implant can be unscrewed easily with <strong>the</strong> aid of a forceps.<br />

for this eventuality, it is advisable to keep a used sterile transfer part in stock as<br />

an aid. this can also be used for subsequent vertical correcti<strong>on</strong> of <strong>the</strong> implant positi<strong>on</strong><br />

if it is screwed <strong>on</strong>to <strong>the</strong> implant again. ensure sufficient countering with <strong>the</strong> adapter in<br />

<strong>the</strong> ratchet and <strong>the</strong> holding key. Subsequent correcti<strong>on</strong> of vertical positi<strong>on</strong> can<br />

interfere c<strong>on</strong>siderably with <strong>the</strong> primary stability of <strong>the</strong> implant.<br />

Implant holder: for no-touch removal of<br />

<strong>the</strong> implant<br />

Premounted transfer part:<br />

compatible with all adapters<br />

Side bars: prevent <strong>the</strong> inner ampoule<br />

from rolling away<br />

Holding screw: for attaching <strong>the</strong><br />

implant and c<strong>on</strong>necting <strong>the</strong> adapter<br />

(short or l<strong>on</strong>g)<br />

Ring: for fixing in <strong>the</strong> adapter<br />

Hexag<strong>on</strong>: attachment for <strong>the</strong> holding<br />

key