Preparati<strong>on</strong> of <strong>the</strong> implant bed for Standard and Standard Plus implants<br />

1. <strong>the</strong> first step c<strong>on</strong>sists of drilling with pilot drill 1 (Ø 2.2 mm) to a depth of about<br />

6 mm using light pressure and with adequate water cooling.<br />

2. <strong>the</strong> alignment pin is <strong>the</strong>n used to check that <strong>the</strong> drill orientati<strong>on</strong> is correct.<br />

3. <strong>the</strong> depth gauge with distance ring enables checking of <strong>the</strong> probable positi<strong>on</strong> of<br />

<strong>the</strong> implant shoulder. <strong>the</strong> distance ring visualises <strong>the</strong> shoulder diameter of 4.8 mm<br />

(rn). at this stage, an unsatisfactory implant axis orientati<strong>on</strong> can still be corrected.<br />

4. Drilling is c<strong>on</strong>tinued to <strong>the</strong> desired depth with pilot drill 1. <strong>the</strong> correct inserti<strong>on</strong><br />

depth is measured, again with <strong>the</strong> aid of <strong>the</strong> alignment pin.<br />

Tip<br />

Particularly with vertically reduced b<strong>on</strong>e availability, it is advisable to take an<br />

X-ray in this phase. The alignment pin is pushed in to visualise <strong>the</strong> drill hole relative<br />

to <strong>the</strong> anatomical structures.<br />

5. <strong>the</strong> preparati<strong>on</strong> of <strong>the</strong> implant bed is c<strong>on</strong>tinued with pilot drill 2 (Ø 2.8 mm) to <strong>the</strong><br />

appropriate inserti<strong>on</strong> depth of <strong>the</strong> selected implant.<br />

6. <strong>the</strong> correct drill depth is <strong>the</strong>n checked with <strong>the</strong> depth gauge. <strong>the</strong> implant bed now<br />

has a diameter of 2.8 mm.<br />

1. 2. 3. 4. 5. 6.<br />

1. Pilot drill 1, Ø 2.2 mm<br />

2. Alignment pin Ø 2.2 mm<br />

3. Depth gauge with distance<br />

indicator Ø 2.2 mm/2.8 mm<br />

4. Pilot drill 1, Ø 2.2 mm<br />

5. Pilot drill 2 Ø 2.8 mm<br />

6. Depth gauge with distance<br />

indicator Ø 2.2 mm/2.8 mm