p <strong>the</strong> easy-to-read user guide ensures a reliable working sequence through colourcoded<br />
arrows and silic<strong>on</strong> sleeves.<br />
p clear illustrati<strong>on</strong>s and drill length stops allow <strong>the</strong> arranged instruments, screws and<br />
healing caps to be checked at a glance for correctness and completeness.<br />
p <strong>the</strong> instruments are positi<strong>on</strong>ed securely in <strong>the</strong> silic<strong>on</strong>e sleeves for sterilisati<strong>on</strong> and<br />
storage.<br />
p <strong>the</strong> cassette can be packed according to <strong>the</strong> working procedure (using <strong>the</strong><br />
handpiece or manually with <strong>the</strong> ratchet).<br />
p <strong>the</strong> surgical cassette also houses a separate screw c<strong>on</strong>tainer in which all <strong>the</strong><br />
required screws and healing caps are arranged, thus providing ease of access to<br />
<strong>the</strong>m.<br />
Guidelines for <strong>the</strong> sterilisati<strong>on</strong> of <strong>the</strong> Surgical cassette<br />
Method Temperature Exposure Time Dry Time<br />
steam sterilizati<strong>on</strong> Prevacuum cycle 134 °c/273 °f min. 4 –18 min 20 – 60 min*<br />
steam sterilizati<strong>on</strong> Gravity cycle<br />
no dry heat sterilizati<strong>on</strong>!<br />
134 °c/273 °f min. 40 min 20 – 60 min*<br />
*Instruments that not thoroughly dried may corrode.<br />
Before sterilisati<strong>on</strong>, <strong>the</strong> cassette is packed (e.g. sealed in foil or wrapped in towels)<br />
in order to keep it sterile.<br />
Important<br />
p chemical sterilisati<strong>on</strong> is not recommended!<br />
p Do not use dry heat sterilisati<strong>on</strong><br />
p ensure that <strong>the</strong> individual sterilisati<strong>on</strong> parameters comply with <strong>the</strong> current regulati<strong>on</strong>s<br />
of <strong>the</strong> respective country.<br />
In order to avoid damaging <strong>the</strong> surgical cassette during autoclaving, it must<br />
be placed correctly in <strong>the</strong> autoclave (see Fig.).<br />
see also DvD “straumann ® Dental implant system-surgery“,<br />
art. no. 150.541, “straumann surgical cassette“.