Basic information on the SURGICAL PROCEDURE - Straumann
Basic information on the SURGICAL PROCEDURE - Straumann
Basic information on the SURGICAL PROCEDURE - Straumann
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Thermoplastic drill template<br />
Art. No. Article Dimensi<strong>on</strong>s Material<br />
040.526 <strong>the</strong>rmoplastic drill templates set, single tooth, c<strong>on</strong>tents:<br />
<strong>the</strong>rmoplastic drill template<br />
(v5)<br />
040.527 <strong>the</strong>rmoplastic drill templates set, free-end situati<strong>on</strong>, c<strong>on</strong>tents:<br />
V5 = 5 comp<strong>on</strong>ents per pack<br />
For more detailed <str<strong>on</strong>g>informati<strong>on</strong></str<strong>on</strong>g>, refer to <strong>the</strong> package insert<br />
“Instructi<strong>on</strong> for use: Thermoplastic drill template sets”, Art. No. 150.901.<br />
a hole is drilled in <strong>the</strong> previously determined implant positi<strong>on</strong> and axis in <strong>the</strong> plaster<br />
anatomic cast. <strong>the</strong>n <strong>the</strong> pin is inserted into <strong>the</strong> drilled hole in order to check <strong>the</strong> implant<br />
positi<strong>on</strong>. subsequently, <strong>the</strong> template is heated in water until it is soft and transparent.<br />
<strong>the</strong> template is placed <strong>on</strong> <strong>the</strong> guide pin and pressed <strong>on</strong>to <strong>the</strong> plaster teeth.<br />
after it has cooled and been disinfected, <strong>the</strong> <strong>the</strong>rmoplastic drill template determines<br />
exactly how <strong>the</strong> 2.2 mm diameter pilot drill is to be guided.<br />
Drill hole template for single tooth gap Drill hole template for free end saddle<br />
drill sleeve height 10 mm,<br />
drill sleeve inside-Ø 2.3 mm<br />
Guide pin (v5) length 20 mm,<br />
Ø 2.3 mm<br />
titanium/<br />
polymer<br />
stainless<br />
steel<br />
Drill for dental laboratory Ø 2.3 mm steel<br />
<strong>the</strong>rmoplastic drill template<br />
(v5)<br />
for more detailed <str<strong>on</strong>g>informati<strong>on</strong></str<strong>on</strong>g> please refer to <strong>the</strong> brochure “<strong>the</strong>rmoplastic drill<br />
template“ art. no. 152.356.<br />
drill sleeve height 10 mm,<br />
drill sleeve inside-Ø 2.3 mm<br />
Guide pin (v5) length 20 mm,<br />
Ø 2.3 mm<br />
titanium/<br />
polymer<br />
stainless<br />
steel<br />
Drill for dental laboratory Ø 2.3 mm steel