Custom made drilling templates<br />

a custom made drilling template can facilitate planning and <strong>the</strong> preparati<strong>on</strong> of <strong>the</strong><br />

implant bed and enables precise use of <strong>the</strong> cutting instruments. <strong>the</strong> basis of planning<br />

when making this template for <strong>the</strong> surgical operati<strong>on</strong> should be <strong>the</strong> desired pros<strong>the</strong>tic<br />

result.<br />

C<strong>on</strong>venti<strong>on</strong>al drill template<br />

Art. No. Article Dimensi<strong>on</strong>s<br />

The following prefabricated comp<strong>on</strong>ents are available for making a custom drilling template.<br />

049.810v4 Drill sleeve with collar height 10 mm,<br />

outer-Ø 3.5 mm,<br />

inner-Ø 2.4 mm<br />

049.818v4 stepped pin for<br />

049.810v4<br />

height 16 mm,<br />

Ø 2.2/3.5 mm<br />

049.816v4 Pin for 049.810v4 height 16 mm,<br />

Ø 2.2 mm<br />

049.817v4 Pin for 049.810v4 height 10 mm,<br />

Ø 2.2 mm<br />

049.819v4 Pin for 049.810v4 height 16 mm,<br />

Ø 3.5 mm<br />

With <strong>the</strong>se comp<strong>on</strong>ents, a surgical drilling template can be produced in <strong>the</strong> usual<br />

manner.<br />

<strong>the</strong> 10 mm l<strong>on</strong>g metal pin can be integrated in <strong>the</strong> template as an X-ray reference<br />

pin. <strong>the</strong> X-ray provides <strong>the</strong> necessary <str<strong>on</strong>g>informati<strong>on</strong></str<strong>on</strong>g> regarding <strong>the</strong> implant axis and <strong>the</strong><br />

implant positi<strong>on</strong>.<br />

<strong>the</strong> drill sleeve is secured in a drilling template in accordance with previous planning.<br />

for definitive checking, an X-ray can also be taken with <strong>the</strong> drilling template. a pilot<br />

drill Ø 2.2 mm is <strong>the</strong>n used for <strong>the</strong> subsequent drilling.<br />

in “fabricati<strong>on</strong> and use of a custom-made drilling template“,<br />

art. no. 152.290, two fabricati<strong>on</strong> methods are shown gradually in a<br />

step by step.<br />

Vacuum-formed template with integral pins<br />

as X-ray reference<br />

Vacuum-formed template with integrated drill<br />

sleeves as drilling template<br />