Custom made drilling templates<br />
a custom made drilling template can facilitate planning and <strong>the</strong> preparati<strong>on</strong> of <strong>the</strong><br />
implant bed and enables precise use of <strong>the</strong> cutting instruments. <strong>the</strong> basis of planning<br />
when making this template for <strong>the</strong> surgical operati<strong>on</strong> should be <strong>the</strong> desired pros<strong>the</strong>tic<br />
result.<br />
C<strong>on</strong>venti<strong>on</strong>al drill template<br />
Art. No. Article Dimensi<strong>on</strong>s<br />
The following prefabricated comp<strong>on</strong>ents are available for making a custom drilling template.<br />
049.810v4 Drill sleeve with collar height 10 mm,<br />
outer-Ø 3.5 mm,<br />
inner-Ø 2.4 mm<br />
049.818v4 stepped pin for<br />
049.810v4<br />
height 16 mm,<br />
Ø 2.2/3.5 mm<br />
049.816v4 Pin for 049.810v4 height 16 mm,<br />
Ø 2.2 mm<br />
049.817v4 Pin for 049.810v4 height 10 mm,<br />
Ø 2.2 mm<br />
049.819v4 Pin for 049.810v4 height 16 mm,<br />
Ø 3.5 mm<br />
With <strong>the</strong>se comp<strong>on</strong>ents, a surgical drilling template can be produced in <strong>the</strong> usual<br />
manner.<br />
<strong>the</strong> 10 mm l<strong>on</strong>g metal pin can be integrated in <strong>the</strong> template as an X-ray reference<br />
pin. <strong>the</strong> X-ray provides <strong>the</strong> necessary <str<strong>on</strong>g>informati<strong>on</strong></str<strong>on</strong>g> regarding <strong>the</strong> implant axis and <strong>the</strong><br />
implant positi<strong>on</strong>.<br />
<strong>the</strong> drill sleeve is secured in a drilling template in accordance with previous planning.<br />
for definitive checking, an X-ray can also be taken with <strong>the</strong> drilling template. a pilot<br />
drill Ø 2.2 mm is <strong>the</strong>n used for <strong>the</strong> subsequent drilling.<br />
in “fabricati<strong>on</strong> and use of a custom-made drilling template“,<br />
art. no. 152.290, two fabricati<strong>on</strong> methods are shown gradually in a<br />
step by step.<br />
Vacuum-formed template with integral pins<br />
as X-ray reference<br />
Vacuum-formed template with integrated drill<br />
sleeves as drilling template<br />