Basic information on the SURGICAL PROCEDURE - Straumann
Basic information on the SURGICAL PROCEDURE - Straumann
Basic information on the SURGICAL PROCEDURE - Straumann
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
1<br />
Vertical implant positi<strong>on</strong><br />
<strong>the</strong> implant can opti<strong>on</strong>ally be submerged<br />
in <strong>the</strong> b<strong>on</strong>e as far as <strong>the</strong> margin of<br />
<strong>the</strong> sLactive/sLa ® surface (a) or, for<br />
es<strong>the</strong>tic reas<strong>on</strong>s, as far as <strong>the</strong> level of<br />
<strong>the</strong> implant shoulder (B). <strong>the</strong> vertical<br />
positi<strong>on</strong> of <strong>the</strong> implant shoulder must be<br />
borne in mind when preparing <strong>the</strong><br />
implant bed.<br />
<strong>the</strong> following rule applies for <strong>the</strong> depth<br />
of inserti<strong>on</strong> to implant shoulder level (B):<br />
SLActive/SLA ® surface + 2 mm =<br />
depth of preparati<strong>on</strong><br />
in <strong>the</strong> es<strong>the</strong>tic area <strong>the</strong> implant shoulder<br />
should be approx. 1– 2 mm apical to<br />
<strong>the</strong> enamel-cementum juncti<strong>on</strong> of <strong>the</strong><br />
c<strong>on</strong>tralateral tooth.<br />
Dental gaps in <strong>the</strong> anterior regi<strong>on</strong><br />
in <strong>the</strong> anterior area, a deeper vertical<br />
implant positi<strong>on</strong> is better for es<strong>the</strong>tic<br />
reas<strong>on</strong>s. in this situati<strong>on</strong>, use of<br />
standard Plus implants which have a<br />
shorter smooth neck secti<strong>on</strong> of <strong>the</strong><br />
implant neck (1.8 mm) compared with<br />
<strong>the</strong> standard implants (2.8 mm) is<br />
recommended.<br />
Oro-facial b<strong>on</strong>e supply<br />
important: <strong>the</strong> oro-facial layer of b<strong>on</strong>e<br />
around <strong>the</strong> implant must be at least<br />
1 mm thick in order to ensure stable<br />
hard and soft tissue c<strong>on</strong>diti<strong>on</strong>s.<br />
2.8 mm<br />
SLActive/SLA ® surface margin (A) Implant shoulder level (B)<br />
standard standard<br />
Plus<br />
tapered<br />
effect<br />
Inserti<strong>on</strong> depth to margin of SLActive/SLA ®<br />
surface<br />
1.8 mm<br />
standard Plus tapered effect<br />
Inserti<strong>on</strong> depth to level of implant shoulder<br />
B<strong>on</strong>e layer at least 1 mm in thickness<br />
Implant shoulder<br />
1.8 mm<br />
B<strong>on</strong>e layer at least 1 mm in thickness