13.07.2015 Views

Manual - Jøtul stoves and fireplaces

Manual - Jøtul stoves and fireplaces

Manual - Jøtul stoves and fireplaces

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

138914 Rev. Q 8/28/1210. Initial System CheckThe burner <strong>and</strong> fan control system consists of the followingbuilt-in or supplied components:1) Remote Transmitter - 3, AAA batteries preinstalled2) Remote Receiver - 4, AA backup batteries preinstalled3) Fan Control Module - switchedAll internal connections have been made at thefactory. The remote controls are preprogramed <strong>and</strong>the entire system tested.NOTE: Check the build date on the shippingcrate label. If it has been more than 6 monthssince the build date, be prepared to replacethe Receiver <strong>and</strong> Transmitter batteries.Follow this procedure for the initial system check followinginstallation:1. Connect the power extension cord to the interiorpower cord <strong>and</strong> to a 120V electrical outlet.2. Turn the Fan Control Module rocker switch to theON position, fig. 35a. It is located in the valve compartment,behind the Receiver control box.3. Slide the Remote Receiver switch to the ON position.The ignitor will generate spark in either IPI orCPI pilot modes. See fig. 35b.4. PURGING THE GAS LINE: Open the gas supplyvalve. When lighting the appliance for the firsttime it will take a few moments to clear the gasline of air. Once the purge is complete, the pilotlight will ignite.5. PILOT FLAME: The pilot flame should be steady -not lifting or floating. The flame should be blue incolor around the pilot hood, with traces of yellowtoward the outer edges. It is important that thepilot flame engulf the top 1/8” of the flame sensor.The pilot flame should project out of the pilothood 1” from both ports extending to reach theburner plate ports. See fig. 36. The pilot flame canbe tuned by turning the adjustment screw locatedon the front of the valve. See fig. 20.6. INSTALLER PLEASE NOTE:CHECK FUNCTIONALITY. The burner, remotecontrol <strong>and</strong> fan functions have each been testedat the factory. However, it is important to runthrough each function <strong>and</strong> be sure to familiarizethe homeowner with the operation procedures.See the Operation section on pages 24-27 fordetails regarding Remote Control functions <strong>and</strong>settings.Open outlet- not usedFlame SensortoFan120V OUT FAN AUX OUT COMON REMOTE OFFIgnitorCarry-over PortstoAccent LampFigure 35b. Initial system settings.Figure 36. Correct Pilot flame pattern.POWER= POWER ON= POWER OFFFigure 35a. Fan Control Module power switch.CPI / Continuous Pilot Ignition(St<strong>and</strong>ing Pilot)ORIPI / Intermittent Pilot IgnitionPRGRemote ReceiverSwitch22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!