138914 Rev. Q 8/28/12• A maximum of two90° or four 45° elbowsmay be used. Wheneverpossible, use 45°elbows instead of 90°elbows as they offerless restriction tothe flow of flue gases<strong>and</strong> intake air. Use ofelbows may adverselyaffect IPI functionality.In such cases, CPImode should be used.• Reduce the overallhorizontal run by4 feet for each 90°elbow, <strong>and</strong> 2 feet foreach 45° elbow.• When two or moreelbows are used in ahorizontal run, a lessrestricted setting maybe more effective thanthat indicated by thetermination zone diagram.VERTICAL RUN35 Ft.(10.67 m)30 Ft.(9.14 m)25 Ft.(7.62 m)20 Ft.(6.10 m)15 Ft.(4.57 m)10 Ft.(3.05 m)ZONEBIntake Air - Fully ClosedFull Exhaust RestrictionZONECIntake Air - Half ClosedHalf Exhaust RestrictionZONEDRequiresuse of CPIMode.See text fordetails.6 ft. Min.VerticalTermination5 Ft.(1.52 m)ZONEAIntake Air - Fully OpenNo Exhaust Restriction2 Ft.(61cm)RequiredMin.VerticalRiseANY VENTING WITH A VERTICAL RISE MUSTTERMINATE (END) WITHIN THE SHADED AREAS.5 Ft.(1.52 m)10 Ft.(3.05 m)15 Ft.(4.57 m)HORIZONTAL RUN20 Ft.(6.09 m)Figure 17 . Vent Termination Diagram.13