13.07.2015 Views

VCP25.1 Project Planning Manual - Bosch Rexroth

VCP25.1 Project Planning Manual - Bosch Rexroth

VCP25.1 Project Planning Manual - Bosch Rexroth

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3-4 <strong>Bosch</strong> <strong>Rexroth</strong> AG | Electric Drives and Controls <strong>Rexroth</strong> IndraControl VCP 25 | R911299720 / 02Safety Instructions for Electric Drives and Controls3.5 Protection Against Contact with Electrical PartsThis section refers to equipment and drive components with voltagesabove 50 Volts.Touching live parts with voltages of 50 Volts and more with bare handsor conductive tools or touching ungrounded housings can be dangerousand cause electric shock. In order to operate electrical equipment,certain parts must unavoidably have dangerous voltages applied tothem.DANGERHigh electrical voltage! Danger to life, severe bodily harm by electricshock!• Only those trained and qualified to work with or on electrical equipmentare permitted to operate, maintain or repair this equipment.• Follow general construction and safety regulations when working onhigh voltage installations.• Before switching on power the ground wire must be permanentlyconnected to all electrical units according to the connection diagram.• Do not operate electrical equipment at any time, even for brief measurementsor tests, if the ground wire is not permanently connectedto the points of the components provided for this purpose.• Before working with electrical parts with voltage higher than 50 V, theequipment must be disconnected from the mains voltage or powersupply. Make sure the equipment cannot be switched on again unintended.• The following should be observed with electrical drive and filter components:Wait five (5) minutes after switching off power to allow capacitors to dischargebefore beginning to work. Measure the voltage on the capacitorsbefore beginning to work to make sure that the equipment is safe totouch.• Never touch the electrical connection points of a component whilepower is turned on.• Install the covers and guards provided with the equipment properlybefore switching the equipment on. Prevent contact with live parts atany time.• A residual-current-operated protective device (RCD) must not beused on electric drives! Indirect contact must be prevented by othermeans, for example, by an overcurrent protective device.• Electrical components with exposed live parts and uncovered highvoltage terminals must be installed in a protective housing, for example,in a control cabinet.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!