13.07.2015 Views

Administration of the Avaya G350 Media Gateway - Avaya Support

Administration of the Avaya G350 Media Gateway - Avaya Support

Administration of the Avaya G350 Media Gateway - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Configuring port redundancyConfiguring port redundancyThis section contains information about port redundancy configuration on <strong>G350</strong> switch portsand includes <strong>the</strong> following topics:●●●●●Port redundancy overview — an overview <strong>of</strong> port redundancy on <strong>the</strong> <strong>G350</strong>Secondary port activation — a description <strong>of</strong> how <strong>the</strong> secondary port is activatedSwitchback — a description <strong>of</strong> how switchback occursPort redundancy CLI commands — a list and description <strong>of</strong> <strong>the</strong> CLI commands used toconfigure port redundancyPort redundancy configuration examples — examples <strong>of</strong> port redundancy configurationsPort redundancy overviewRedundancy involves <strong>the</strong> duplication <strong>of</strong> devices, services, or connections, so, in <strong>the</strong> event <strong>of</strong> afailure, <strong>the</strong> redundant duplicate can take over for <strong>the</strong> one that failed.Since computer networks are critical for business operations, it is vital to ensure that <strong>the</strong>network continues to function even if a piece <strong>of</strong> equipment fails. Even <strong>the</strong> most reliableequipment might fail on occasion, but a redundant component can ensure that <strong>the</strong> networkcontinues to operate despite such failure.To achieve port redundancy, you can define a redundancy relationship between any two ports ina switch. One port is defined as <strong>the</strong> primary port and <strong>the</strong> o<strong>the</strong>r as <strong>the</strong> secondary port. If <strong>the</strong>primary port fails, <strong>the</strong> secondary port takes over.You can configure up to 25 pairs <strong>of</strong> ports per chassis. Each pair contains a primary andsecondary port. You can configure any type <strong>of</strong> E<strong>the</strong>rnet port to be redundant to any o<strong>the</strong>r. Youcan configure redundant ports from among <strong>the</strong> E<strong>the</strong>rnet LAN port on <strong>the</strong> <strong>G350</strong> front panel and<strong>the</strong> E<strong>the</strong>rnet ports (1-24) and <strong>the</strong> Gigabit E<strong>the</strong>rnet port (51) on <strong>the</strong> MM314 <strong>Media</strong> Module.Secondary port activationThe secondary port takes over within one second and is activated when <strong>the</strong> primary port linkstops functioning. Subsequent switchovers take place after <strong>the</strong> minimum time betweenswitchovers has elapsed. To set <strong>the</strong> minimum time between switchovers, use <strong>the</strong> set portredundancy-intervals command.Issue 3 January 2005 139

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!