YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ServiceWARNINGTo avoid serious injury and equipmentdamage, do not lift the equipment by theair motor lift ring if the total weight of theequipment exceeds 550 lb (250 kg). Thelift ring cannot support that weight.Model 208356 Shown103NOTE: Repair kit 206734 is available. For best results,use all the new parts in the kit, even if the old oneslook good. Parts included in the kit are marked with anasterisk, for example (16*).51NOTE: Inspect all parts as they are disassembled andreplace any worn or damaged parts.DisassemblyWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow thePressure Relief Procedure on page 6.45137334634321. Relieve the pressure.2. Disconnect the displacement pump. Disconnectthe ground wire. Set the motor upright on a workbench.282745240NOTE: Refer to Fig. 3 for steps 3 to 5.3. Remove the air inlet fitting (3). Remove the screws(10) and lift off the air motor shield (51). Removethe grommet (40).4. Unscrew the spring retainers (32) and remove thespring (34), guide (33), and plunger (46) from eachside of the detent housing (45).5. Remove the four screws (13) and lockwashers (7)from the detent housing (45). Carefully lift thehousing so the rollers (4) and axles (52) do not fallout. Remove the rollers, axles, washer (27), andrubber pad (28).Fig. 3072688 307049