fans for atex explosive atmospheres and other applications - Sodeca
fans for atex explosive atmospheres and other applications - Sodeca fans for atex explosive atmospheres and other applications - Sodeca
CMP/AL CJMP/ALDimensions in mmCMP/AL-512...820OutletInletModel A B1 B2 C C1 C2 øD1* ød ød1 ød2 E H1 I J J1 J2 K k2 L øOCMP-512-4M/AL 182 207 118 197.5 159 38.5 112 140 132 M4 81 69 106 118 - 105 72 93 86 5.5CMP-514-4M/AL 225 254 150 210 165 45 140 169 151.5 M4 100 91 122 147 64 128 83 105 107 9.5CMP-616-4M/AL 258 297 173.5 270 214 56 160 204 180 M6 110 105.5 153 172 - 147 103 128 125 7CMP-820-4M/AL 322 377 223 345.5 277 68.5 200 247 230 M6 137.5 137 184 213 94.5 189 130 160 156 9* Recommended nominal diameter for duct.CJMP/AL-512...820Model A B C øD1 øD2 E1 E2 F G H ICJMP/AL-512 330 250 280 100 100 53 59 85 159 75 90CJMP/AL-514 330 270 320 125 125 53 58 104 190 82 100CJMP/AL-616 370 300 370 135 135 53 52 114 217 100 110CJMP/AL-820 450 400 450 135 195 53 51 142 267 112 130Characteristic CurvesQ = Airflow in m 3 /h, m 3 /s and cfm.Pe= Static pressure in mm.w.c., Pa and inwg.4M=1500 r/min46
CMR/ATEXCMR/ATEXimpellerRobust centrifugalmedium-pressure fansfitted with backwards-curvedwith ATEX certificationRobust centrifugal single-inlet, medium-pressurefans to work in explosive atmospheres.Fan:• Steel sheet casing• Impeller with backward-curved blades madefrom robust sheet steel• Anti-spark aspiration ring in copper or aluminiumMotor:• Class F motors, with ball bearings, IP55 protectionand ATEX certification, EEx”e” explosion-proof,EEx”d” flame-resistant• Three-phase 230/400V.-50Hz. (up to 5.5CV.)and 400/690V.-50Hz. (power over 5.5CV.)• Max. air temperature to transport:-20ºC.+ 80ºC.EEx “e” mark: II 2 G. EEx eEEx “d” mark: II 2 G. EEx dDIP55 mark: II 3 D. IP55DIP65 mark: II 2 D. IP65Notified authority: L.O.M.ID:LOM3ATEX147Finish:• Rust retardant with ATEX paint, freeof ferric components, in polyesterresin, polymerised at 190ºC, withprior alkaline degreasing and withphosphate-free pre-treatmentOn request:• Motors with built-in PTC• Special windings for differentvoltages and frequencies• ATEX construction for differentcategories• Made from stainless steelOrder codeCMR/ATEX 1650 2T 5,5 DIP65Robust centrifugal medium-pressure fans,fitted with backward-curved impeller withATEX certificationEEx “e” mark: II 2 G. EEx eEEx “d” mark: II 2 G. EEx dDIP55 mark: II 3 D. IP55DIP65 mark: II 2 D. IP65Notified authority: L.O.M.ID: LOM3ATEX147Impeller sizeNumber of T=Three-phasemotor poles2=2900 r/min. 50 Hz4=1400 r/min. 50 Hz6=900 r/min. 50 HzPowermotor (c.v)EEx-e: Mark:II 2 G. EEx e IIBT3EEx “d” mark:II 2 G. EEx d IIBT5DIP55 mark:II 3 D. IP55DIP65 mark:II 2 D. IP65Technical characteristicsModelSpeed(r/min)Installedpower(kW)Maximumairflow(m 3 /h)Sound pressurelevel dB(A)Approx. weightwith motor (Kg)EEx-e EEx-dCMR-1240-4T/ATEX 1455 0.75 5800 71 70 84CMR-1445-2T/ATEX 2915 7.50 16500 87 141 163CMR-1445-4T/ATEX 1460 1.10 8030 72 93 112CMR-1650-2T/ATEX 2910 11.00 18850 89 178 258CMR-1650-4T/ATEX 1440 1.50 10500 74 114 134CMR-1650-6T/ATEX 970 0.75 7410 64 111 130CMR-1856-4T/ATEX 1455 3.00 15150 79 152 175CMR-1856-6T/ATEX 965 1.10 10050 70 145 166CMR-2063-4T/ATEX 1460 5.50 24450 80 225 264CMR-2063-6T/ATEX 935 1.50 16100 71 209 233CMR-2271-4T/ATEX 1465 11.00 34610 85 315 412CMR-2271-6T/ATEX 950 3.00 22750 76 280 320CMR-2380-4T/ATEX 1400 22.00 48000 83 416 495CMR-2380-6T/ATEX 900 7.50 30000 75 363 44147
- Page 2: OURCOMMITMENTTO THEENVIRONMENTSodec
- Page 5 and 6: FANS FOR: NAVAL AND OFF-SHORE APPLI
- Page 7 and 8: FULFILMENT OF STANDARDSSODECA's fan
- Page 10 and 11: Fans for ATEX EXPLOSIVE ATMOSPHERES
- Page 12 and 13: Explosivity values for combustible
- Page 14: HCDF HDFHCDFHDFHCDFHDFHCDF: Axial f
- Page 22 and 23: HC/ATEXCharacteristic curvesQ = Air
- Page 24 and 25: HCH/ATEX HCT/ATEXTechnical characte
- Page 26 and 27: HCH/ATEX HCT/ATEXCharacteristic cur
- Page 28 and 29: HCH/ATEX HCT/ATEXCharacteristic cur
- Page 30 and 31: HTM/ATEXHTM/ATEXMobile long-cased f
- Page 32 and 33: HPX/ATEXHPX/ATEXCased axial fans wi
- Page 34 and 35: HPX/ATEXCharacteristic curvesQ = Ai
- Page 37 and 38: CPV/ATEXCharacteristic curvesQ = Ai
- Page 39 and 40: CMA/ATEXAcoustic featuresThe specif
- Page 41 and 42: CMP/ATEXCMP/ATEX impellerCentrifuga
- Page 43 and 44: CMP/ATEXDimensions in mmCMP-616..0,
- Page 45: CMP/AL CJMP/ALCMP/ALCJMP/ALCMP/AL:
- Page 49 and 50: CMR/ATEXCharacteristic CurvesQ = Ai
- Page 52 and 53: CAS/ATEXDimensions in mmCAS/ATEX-12
- Page 54 and 55: CAS/ATEXCharacteristic CurvesQ = Ai
- Page 56 and 57: CA/ATEXAcoustic featuresThe specifi
- Page 58 and 59: HT/ATEXHT/ATEXAxial roof fans with
- Page 60 and 61: HT/ATEXCharacteristic curvesQ = Air
- Page 62 and 63: CHT/ATEX CVT/ATEXAcoustic featuresT
- Page 64 and 65: CHT/ATEX CVT/ATEXCharacteristic cur
- Page 66 and 67: HCT/ATEX HFT/ATEXTechnical characte
- Page 68 and 69: HTPHTPCased high-pressure axial fan
- Page 70 and 71: HTPEXAMPLE OF SELECTIONCharacterist
- Page 72 and 73: HTPCharacteristic curvesQ = Airflow
- Page 74 and 75: HTPCharacteristic curvesQ = Airflow
- Page 76 and 77: HTPCharacteristic curvesQ = Airflow
- Page 78 and 79: HTPCharacteristic curvesQ = Airflow
- Page 80 and 81: HTPCharacteristic curvesQ = Airflow
- Page 82 and 83: HBADimensions in mmHBA-31...50HBA-6
- Page 84 and 85: CMP/MARTechnical characteristicsMod
- Page 86 and 87: CMP/MARCharacteristic curvesSee pag
- Page 88 and 89: CMPITechnical characteristicsModelS
- Page 90 and 91: CMPIDimensions in mmCMPI-1435...256
- Page 92 and 93: CMP/ATEX CMP/MAR CMPICharacteristic
- Page 94 and 95: CMP/ATEX CMP/MAR CMPICharacteristic
CMR/ATEXCMR/ATEXimpellerRobust centrifugalmedium-pressure <strong>fans</strong>fitted with backwards-curvedwith ATEX certificationRobust centrifugal single-inlet, medium-pressure<strong>fans</strong> to work in <strong>explosive</strong> <strong>atmospheres</strong>.Fan:• Steel sheet casing• Impeller with backward-curved blades madefrom robust sheet steel• Anti-spark aspiration ring in copper or aluminiumMotor:• Class F motors, with ball bearings, IP55 protection<strong>and</strong> ATEX certification, EEx”e” explosion-proof,EEx”d” flame-resistant• Three-phase 230/400V.-50Hz. (up to 5.5CV.)<strong>and</strong> 400/690V.-50Hz. (power over 5.5CV.)• Max. air temperature to transport:-20ºC.+ 80ºC.EEx “e” mark: II 2 G. EEx eEEx “d” mark: II 2 G. EEx dDIP55 mark: II 3 D. IP55DIP65 mark: II 2 D. IP65Notified authority: L.O.M.ID:LOM3ATEX147Finish:• Rust retardant with ATEX paint, freeof ferric components, in polyesterresin, polymerised at 190ºC, withprior alkaline degreasing <strong>and</strong> withphosphate-free pre-treatmentOn request:• Motors with built-in PTC• Special windings <strong>for</strong> differentvoltages <strong>and</strong> frequencies• ATEX construction <strong>for</strong> differentcategories• Made from stainless steelOrder codeCMR/ATEX 1650 2T 5,5 DIP65Robust centrifugal medium-pressure <strong>fans</strong>,fitted with backward-curved impeller withATEX certificationEEx “e” mark: II 2 G. EEx eEEx “d” mark: II 2 G. EEx dDIP55 mark: II 3 D. IP55DIP65 mark: II 2 D. IP65Notified authority: L.O.M.ID: LOM3ATEX147Impeller sizeNumber of T=Three-phasemotor poles2=2900 r/min. 50 Hz4=1400 r/min. 50 Hz6=900 r/min. 50 HzPowermotor (c.v)EEx-e: Mark:II 2 G. EEx e IIBT3EEx “d” mark:II 2 G. EEx d IIBT5DIP55 mark:II 3 D. IP55DIP65 mark:II 2 D. IP65Technical characteristicsModelSpeed(r/min)Installedpower(kW)Maximumairflow(m 3 /h)Sound pressurelevel dB(A)Approx. weightwith motor (Kg)EEx-e EEx-dCMR-1240-4T/ATEX 1455 0.75 5800 71 70 84CMR-1445-2T/ATEX 2915 7.50 16500 87 141 163CMR-1445-4T/ATEX 1460 1.10 8030 72 93 112CMR-1650-2T/ATEX 2910 11.00 18850 89 178 258CMR-1650-4T/ATEX 1440 1.50 10500 74 114 134CMR-1650-6T/ATEX 970 0.75 7410 64 111 130CMR-1856-4T/ATEX 1455 3.00 15150 79 152 175CMR-1856-6T/ATEX 965 1.10 10050 70 145 166CMR-2063-4T/ATEX 1460 5.50 24450 80 225 264CMR-2063-6T/ATEX 935 1.50 16100 71 209 233CMR-2271-4T/ATEX 1465 11.00 34610 85 315 412CMR-2271-6T/ATEX 950 3.00 22750 76 280 320CMR-2380-4T/ATEX 1400 22.00 48000 83 416 495CMR-2380-6T/ATEX 900 7.50 30000 75 363 44147