fans for atex explosive atmospheres and other applications - Sodeca
fans for atex explosive atmospheres and other applications - Sodeca fans for atex explosive atmospheres and other applications - Sodeca
CMP/ATEXDimensions in mmCMP-1435...2050InletOutletEEx-”e” EEx-”d”Model A B C C1 C C1 C2 øD1* ød ød1 ød2 E H H1 I J J1 K k1 L øO øO1 V v X x1 YCMP-1435-4T-4/ATEX 573.5 715 527 409 577 459 118 355 422 394 M.8 250 445 242.5 292 342.5 159 228 133 280 11.5 12 456 420 333 136.5 150CMP-1435-4T-5,5/ATEX 573.5 715 572 545 597 479 118 355 422 394 M.8 250 445 242.5 292 342.5 159 228 133 280 11.5 12 456 420 333 136.5 150CMP-1435-4T-7,5/ATEX 573.5 715 610 492 670 552 118 355 422 394 M.8 250 445 242.5 292 342.5 159 228 133 280 11.5 12 456 420 333 136.5 150CMP-1640-4T-5,5/ATEX 634 799 596 465 621 491 130 400 464 438 M.8 270 495 271 336 404 185 250 150 321 11.5 12 500 460 327 133.5 162.5CMP-1640-4T-7,5/ATEX 634 799 634 504 693 563 130 400 464 438 M.8 270 495 271 336 404 185 250 150 321 11.5 12 500 460 327 133.5 162.5CMP-1640-4T-10/ATEX 634 799 634 504 693 563 130 400 464 438 M.8 270 495 271 336 404 185 250 150 321 11.5 12 500 460 327 133.5 162.5CMP-1845-4T-7,5/ATEX 711 901 668 521 727 580 147 450 515 485 M.8 302 560 305 370 444 202 284 164 361 11.5 12 538 502 340 140 179.5CMP-1845-4T-10/ATEX 711 901 668 521 727 580 147 450 515 485 M.8 302 560 305 370 444 202 284 164 361 11.5 12 538 502 340 140 179.5CMP-2050-4T-10/ATEX 797 987 700.5 538 759 596.5 162.5 500 565 535 M.10 345 610 313 411 544 250 315 182.5 451 11.5 12 653 615 435 188 196CMP-2050-4T-15/ATEX 797 987 818.5 656 923.5 764.5 162.5 500 565 535 M.10 345 610 313 411 544 250 315 182.5 451 11.5 12 653 615 435 188 196CMP-2050-4T-20/ATEX 797 987 859.5 697 923.5 764.5 162.5 500 565 535 M.10 345 610 313 411 544 250 315 182.5 451 11.5 12 653 615 435 188 196* Recommended nominal diameter for duct.Characteristic curvesSee page 91PositionsLG 270 standard supplyLG 180 and RD 180 positions on request and with special fixing measures.LG 0 LG 45 LG 90 LG 135 LG 180 LG 225 LG 270 LG 315RD 0 RD 45 RD 90 RD 135 RD 180 RD 225 RD 270 RD 315AccessoriesSee accessories section.INT AR RFT/ RFM PANELS RPA B BIC ACE/ATEX CJACUS REGS44
CMP/AL CJMP/ALCMP/ALCJMP/ALCMP/AL: Aluminium spark-proof fans certifiedaccording to standard UNE 60-601-2006 and therequirements of natural gas boiler roomsCJMP/AL: Aluminium spark-proof ventilationunits certified according to standardUNE 60-601-2006 and the requirementsof natural gas boiler roomsMade fromspark-proofFan:• Impeller with forward-facing blades made from aluminium sheet• CMP/AL: Casing made from aluminium sheet• CJMP/AL: Galvanized sheet steel structure.Motor:• Class F motors with ball bearings, IP55 protection• Single-phase 230V.-50Hz.• Max. air temperature to transport: -20ºC.+ 120ºC.Finish:• CMP/AL: Anticorrosive finish in polyester resin, polymerised at190ºC, after alkaline degreasing and phosphate-free pre-treatment.• CJMP/AL: Anticorrosive galvanized sheet steel.Dynamically-balancedaluminium coils withhighly robust centresOn request:• Special windings for different voltages• ATEX certification, Category 2Order codeCMP 616 4M /ALCMP/AL: Aluminiumspark-proof fansCJMP/AL: Aluminiumspark-proofventilation unitsImpeller sizeNumber ofmotor poles4=1400 r/min. 50 HzM=Single-phaseMade fromspark-proofin aluminiumTechnical characteristicsModelSpeed(r/min)Maximum admissiblecurrent (A)230VInstalledpower(kW)Maximumairflow(m 3 /h)Sound leveldB(A)Approx.weight(Kg)CMP-512-4M/AL 1440 0.60 0.05 275 55 3.5CMP-514-4M/AL 1440 0.60 0.08 660 58 4.5CMP-616-4M/AL 1400 0.72 0.10 1000 61 7.5CMP-820-4M/AL 1400 2.00 0.25 2100 66 10.0CJMP-512-4M/AL 1440 0.60 0.05 275 50 8.5CJMP-514-4M/AL 1440 0.60 0.08 660 54 10.5CJMP-616-4M/AL 1400 0.72 0.10 1000 57 14.5CJMP-820-4M/AL 1400 2.00 0.25 2100 60 18.045
- Page 2: OURCOMMITMENTTO THEENVIRONMENTSodec
- Page 5 and 6: FANS FOR: NAVAL AND OFF-SHORE APPLI
- Page 7 and 8: FULFILMENT OF STANDARDSSODECA's fan
- Page 10 and 11: Fans for ATEX EXPLOSIVE ATMOSPHERES
- Page 12 and 13: Explosivity values for combustible
- Page 14: HCDF HDFHCDFHDFHCDFHDFHCDF: Axial f
- Page 22 and 23: HC/ATEXCharacteristic curvesQ = Air
- Page 24 and 25: HCH/ATEX HCT/ATEXTechnical characte
- Page 26 and 27: HCH/ATEX HCT/ATEXCharacteristic cur
- Page 28 and 29: HCH/ATEX HCT/ATEXCharacteristic cur
- Page 30 and 31: HTM/ATEXHTM/ATEXMobile long-cased f
- Page 32 and 33: HPX/ATEXHPX/ATEXCased axial fans wi
- Page 34 and 35: HPX/ATEXCharacteristic curvesQ = Ai
- Page 37 and 38: CPV/ATEXCharacteristic curvesQ = Ai
- Page 39 and 40: CMA/ATEXAcoustic featuresThe specif
- Page 41 and 42: CMP/ATEXCMP/ATEX impellerCentrifuga
- Page 43: CMP/ATEXDimensions in mmCMP-616..0,
- Page 47 and 48: CMR/ATEXCMR/ATEXimpellerRobust cent
- Page 49 and 50: CMR/ATEXCharacteristic CurvesQ = Ai
- Page 52 and 53: CAS/ATEXDimensions in mmCAS/ATEX-12
- Page 54 and 55: CAS/ATEXCharacteristic CurvesQ = Ai
- Page 56 and 57: CA/ATEXAcoustic featuresThe specifi
- Page 58 and 59: HT/ATEXHT/ATEXAxial roof fans with
- Page 60 and 61: HT/ATEXCharacteristic curvesQ = Air
- Page 62 and 63: CHT/ATEX CVT/ATEXAcoustic featuresT
- Page 64 and 65: CHT/ATEX CVT/ATEXCharacteristic cur
- Page 66 and 67: HCT/ATEX HFT/ATEXTechnical characte
- Page 68 and 69: HTPHTPCased high-pressure axial fan
- Page 70 and 71: HTPEXAMPLE OF SELECTIONCharacterist
- Page 72 and 73: HTPCharacteristic curvesQ = Airflow
- Page 74 and 75: HTPCharacteristic curvesQ = Airflow
- Page 76 and 77: HTPCharacteristic curvesQ = Airflow
- Page 78 and 79: HTPCharacteristic curvesQ = Airflow
- Page 80 and 81: HTPCharacteristic curvesQ = Airflow
- Page 82 and 83: HBADimensions in mmHBA-31...50HBA-6
- Page 84 and 85: CMP/MARTechnical characteristicsMod
- Page 86 and 87: CMP/MARCharacteristic curvesSee pag
- Page 88 and 89: CMPITechnical characteristicsModelS
- Page 90 and 91: CMPIDimensions in mmCMPI-1435...256
- Page 92 and 93: CMP/ATEX CMP/MAR CMPICharacteristic
CMP/AL CJMP/ALCMP/ALCJMP/ALCMP/AL: Aluminium spark-proof <strong>fans</strong> certifiedaccording to st<strong>and</strong>ard UNE 60-601-2006 <strong>and</strong> therequirements of natural gas boiler roomsCJMP/AL: Aluminium spark-proof ventilationunits certified according to st<strong>and</strong>ardUNE 60-601-2006 <strong>and</strong> the requirementsof natural gas boiler roomsMade fromspark-proofFan:• Impeller with <strong>for</strong>ward-facing blades made from aluminium sheet• CMP/AL: Casing made from aluminium sheet• CJMP/AL: Galvanized sheet steel structure.Motor:• Class F motors with ball bearings, IP55 protection• Single-phase 230V.-50Hz.• Max. air temperature to transport: -20ºC.+ 120ºC.Finish:• CMP/AL: Anticorrosive finish in polyester resin, polymerised at190ºC, after alkaline degreasing <strong>and</strong> phosphate-free pre-treatment.• CJMP/AL: Anticorrosive galvanized sheet steel.Dynamically-balancedaluminium coils withhighly robust centresOn request:• Special windings <strong>for</strong> different voltages• ATEX certification, Category 2Order codeCMP 616 4M /ALCMP/AL: Aluminiumspark-proof <strong>fans</strong>CJMP/AL: Aluminiumspark-proofventilation unitsImpeller sizeNumber ofmotor poles4=1400 r/min. 50 HzM=Single-phaseMade fromspark-proofin aluminiumTechnical characteristicsModelSpeed(r/min)Maximum admissiblecurrent (A)230VInstalledpower(kW)Maximumairflow(m 3 /h)Sound leveldB(A)Approx.weight(Kg)CMP-512-4M/AL 1440 0.60 0.05 275 55 3.5CMP-514-4M/AL 1440 0.60 0.08 660 58 4.5CMP-616-4M/AL 1400 0.72 0.10 1000 61 7.5CMP-820-4M/AL 1400 2.00 0.25 2100 66 10.0CJMP-512-4M/AL 1440 0.60 0.05 275 50 8.5CJMP-514-4M/AL 1440 0.60 0.08 660 54 10.5CJMP-616-4M/AL 1400 0.72 0.10 1000 57 14.5CJMP-820-4M/AL 1400 2.00 0.25 2100 60 18.045