fans for atex explosive atmospheres and other applications - Sodeca
fans for atex explosive atmospheres and other applications - Sodeca fans for atex explosive atmospheres and other applications - Sodeca
HCDF HDFHCDFHDFHCDFHDFHCDF: Axial fans with square frame,with ATEX certification EEx dHDF: Axial fans with circular frame,with ATEX certification EEx dWall-mounted axial fans (HCDF) or circular axial fans (HDF) withATEX certification and CEE ExII2G EExd flame-resistant motor towork in explosive atmospheres.Fan:• Impeller made from cast aluminium• Airflow direction from motor to impeller• Spark-proof stuffing-box included• HCDF: Support frame in aluminium sheet• HCDF: Protection guard against contacts, in accordance withstandard UNE 100-250• HDF: Support ring in sheet steel with aluminium strip in theimpeller area in accordance with Standard EN-14986:2006Motor:• Class F motors with ball bearings, IP-55 protection,with ATEX certification, EEx”d” IIBT4 flame-resistant• Three-phase 230/400V.-50Hz. (up to 5.5CV.)and 400/690V.-50Hz. (power over 5.5CV.)• Working temperature: -20ºC.+ 40ºC.Mark: II 2 G. EEx dNotified authority: L.O.M.ID: LOM3ATEX0157Finish:• Rust retardant with ATEX paint, freeof ferric components, in polyesterresin, polymerised at 190ºC, withprior alkaline degreasing and withphosphate-free pre-treatmentOn request:• Special windings for different voltagesand frequencies• ATEX construction for differentcategories• Fans with two-speed motor.Aluminium strip to preventsparks in accordance withstandard EN-14986:2006Order codeHCDF 45 4THCDF: Axial fans with square frame, with ATEXcertificationHDF: Axial fans with circular frame, with ATEXcertificationMark: II 2 G. EEx d IIBT4Notified authority: L.O.M.ID: LOM3ATEX0157Impeller diameter(cm)Number ofmotor poles4=1400 r/min. 50 Hz6=900 r/min. 50 HzT=Three-phaseM=Single-phaseTechnical characteristicsModelSpeed(r/min)Maximum admissiblecurrent (A)230V 400VInstalledpower(kW)Maximumairflow(m 3 /h)Sound pressurelevel dB(A)Approx. weight(Kg)HCDF-25-4T 1370 0.78 0.45 0.09 890 51 6.5HCDF-25-4M 1410 0.72 0.06 890 51 6.5HCDF-31-4T 1370 0.78 0.45 0.09 1700 54 7.5HCDF-31-4M 1410 0.72 0.06 1700 54 7.5HCDF-35-4T 1370 0.78 0.45 0.09 2950 58 8.5HCDF-35-4M 1410 0.72 0.06 2950 58 8.5HCDF-40-4T 1420 1.30 0.75 0.25 4400 63 12.5HCDF-40-4M 1400 3.25 0.25 4400 63 15.0HCDF-45-4T 1420 1.30 0.75 0.25 6450 66 14.5HCDF-45-4M 1400 3.25 0.25 6450 66 17.0HCDF-45-6T 925 0.95 0.55 0.12 5200 57 14.5HCDF-50-4T 1390 1.73 1.00 0.37 8600 69 16.5HCDF-50-6T 920 1.56 0.90 0.18 6300 59 16.0HCDF-56-4T 1390 3.08 1.78 0.55 10500 72 36.5HCDF-56-6T 910 1.59 0.92 0.25 8400 63 30.5HDF-63-4T 1415 4.50 2.60 1.10 15100 76 49.0HDF-63-6T 905 2.37 1.37 0.37 12400 64 36.5HDF-71-4T 1400 5.20 3.00 1.10 20000 79 52.0HDF-71-6T 900 3.29 1.90 0.55 13800 67 43.0HDF-80-4T 1400 13.86 8.00 3.00 34100 83 76.0HDF-80-6T 910 5.89 3.40 1.10 20200 72 65.5HDF-90-4T 1400 15.42 8.90 4.00 48200 89 87.0HDF-90-6T 920 7.45 4.30 1.50 30000 77 83.014
- Page 2: OURCOMMITMENTTO THEENVIRONMENTSodec
- Page 5 and 6: FANS FOR: NAVAL AND OFF-SHORE APPLI
- Page 7 and 8: FULFILMENT OF STANDARDSSODECA's fan
- Page 10 and 11: Fans for ATEX EXPLOSIVE ATMOSPHERES
- Page 12 and 13: Explosivity values for combustible
- Page 18: HC/ATEXTechnical characteristicsMod
- Page 23 and 24: HCH/ATEX HCT/ATEXHCH/ATEXHCT/ATEXHC
- Page 25 and 26: HCH/ATEX HCT/ATEXDimensions in mmHC
- Page 27 and 28: HCH/ATEX HCT/ATEXCharacteristic cur
- Page 29 and 30: HCH/ATEX HCT/ATEXCharacteristic cur
- Page 31 and 32: HTM/ATEXDimensions in mmModel A B C
- Page 33 and 34: HPX/ATEXAcoustic featuresThe specif
- Page 35: CPV/ATEXCPV/ATEX ATEXPlastic antico
- Page 38 and 39: CMA/ATEXCMA/ATEX withCentrifugal me
- Page 40 and 41: CMA/ATEXCharacteristic curvesQ = Ai
- Page 42 and 43: CMP/ATEXTechnical characteristicsMo
- Page 44 and 45: CMP/ATEXDimensions in mmCMP-1435...
- Page 46 and 47: CMP/AL CJMP/ALDimensions in mmCMP/A
- Page 48 and 49: CMR/ATEXAcoustic featuresThe specif
- Page 50: CAS/ATEXCAS/ATEXCentrifugal single-
- Page 53 and 54: CAS/ATEXCharacteristic CurvesQ = Ai
- Page 55 and 56: CA/ATEXCA/ATEXCentrifugal single-in
- Page 57 and 58: CA/ATEXCharacteristic CurvesQ = Air
- Page 59 and 60: HT/ATEXTechnical characteristicsMod
- Page 61 and 62: CHT/ATEX CVT/ATEXCHT/ATEXCVT/ATEXCH
- Page 63 and 64: CHT/ATEX CVT/ATEXCharacteristic cur
HCDF HDFHCDFHDFHCDFHDFHCDF: Axial <strong>fans</strong> with square frame,with ATEX certification EEx dHDF: Axial <strong>fans</strong> with circular frame,with ATEX certification EEx dWall-mounted axial <strong>fans</strong> (HCDF) or circular axial <strong>fans</strong> (HDF) withATEX certification <strong>and</strong> CEE ExII2G EExd flame-resistant motor towork in <strong>explosive</strong> <strong>atmospheres</strong>.Fan:• Impeller made from cast aluminium• Airflow direction from motor to impeller• Spark-proof stuffing-box included• HCDF: Support frame in aluminium sheet• HCDF: Protection guard against contacts, in accordance withst<strong>and</strong>ard UNE 100-250• HDF: Support ring in sheet steel with aluminium strip in theimpeller area in accordance with St<strong>and</strong>ard EN-14986:2006Motor:• Class F motors with ball bearings, IP-55 protection,with ATEX certification, EEx”d” IIBT4 flame-resistant• Three-phase 230/400V.-50Hz. (up to 5.5CV.)<strong>and</strong> 400/690V.-50Hz. (power over 5.5CV.)• Working temperature: -20ºC.+ 40ºC.Mark: II 2 G. EEx dNotified authority: L.O.M.ID: LOM3ATEX0157Finish:• Rust retardant with ATEX paint, freeof ferric components, in polyesterresin, polymerised at 190ºC, withprior alkaline degreasing <strong>and</strong> withphosphate-free pre-treatmentOn request:• Special windings <strong>for</strong> different voltages<strong>and</strong> frequencies• ATEX construction <strong>for</strong> differentcategories• Fans with two-speed motor.Aluminium strip to preventsparks in accordance withst<strong>and</strong>ard EN-14986:2006Order codeHCDF 45 4THCDF: Axial <strong>fans</strong> with square frame, with ATEXcertificationHDF: Axial <strong>fans</strong> with circular frame, with ATEXcertificationMark: II 2 G. EEx d IIBT4Notified authority: L.O.M.ID: LOM3ATEX0157Impeller diameter(cm)Number ofmotor poles4=1400 r/min. 50 Hz6=900 r/min. 50 HzT=Three-phaseM=Single-phaseTechnical characteristicsModelSpeed(r/min)Maximum admissiblecurrent (A)230V 400VInstalledpower(kW)Maximumairflow(m 3 /h)Sound pressurelevel dB(A)Approx. weight(Kg)HCDF-25-4T 1370 0.78 0.45 0.09 890 51 6.5HCDF-25-4M 1410 0.72 0.06 890 51 6.5HCDF-31-4T 1370 0.78 0.45 0.09 1700 54 7.5HCDF-31-4M 1410 0.72 0.06 1700 54 7.5HCDF-35-4T 1370 0.78 0.45 0.09 2950 58 8.5HCDF-35-4M 1410 0.72 0.06 2950 58 8.5HCDF-40-4T 1420 1.30 0.75 0.25 4400 63 12.5HCDF-40-4M 1400 3.25 0.25 4400 63 15.0HCDF-45-4T 1420 1.30 0.75 0.25 6450 66 14.5HCDF-45-4M 1400 3.25 0.25 6450 66 17.0HCDF-45-6T 925 0.95 0.55 0.12 5200 57 14.5HCDF-50-4T 1390 1.73 1.00 0.37 8600 69 16.5HCDF-50-6T 920 1.56 0.90 0.18 6300 59 16.0HCDF-56-4T 1390 3.08 1.78 0.55 10500 72 36.5HCDF-56-6T 910 1.59 0.92 0.25 8400 63 30.5HDF-63-4T 1415 4.50 2.60 1.10 15100 76 49.0HDF-63-6T 905 2.37 1.37 0.37 12400 64 36.5HDF-71-4T 1400 5.20 3.00 1.10 20000 79 52.0HDF-71-6T 900 3.29 1.90 0.55 13800 67 43.0HDF-80-4T 1400 13.86 8.00 3.00 34100 83 76.0HDF-80-6T 910 5.89 3.40 1.10 20200 72 65.5HDF-90-4T 1400 15.42 8.90 4.00 48200 89 87.0HDF-90-6T 920 7.45 4.30 1.50 30000 77 83.014