fans for atex explosive atmospheres and other applications - Sodeca
fans for atex explosive atmospheres and other applications - Sodeca fans for atex explosive atmospheres and other applications - Sodeca
HTMHCharacteristic curvesQ = Airflow in m 3 /h, m 3 /s and cfm.Pe= Static pressure in mm.w.c., Pa and inwg.HTMH-90HTMH-100Validation of the sound pressure according to distanceThe sound level may vary depending on the roof structure.AccessoriesSee accessories sectionINTAETARRFTRT110
HTTALHTTALHTTALOrder code+Mixed (wind + dynamic) roof fanswith adjustable baseRoof fan operating by means of natural convection(due to depression of hot air and the Venturi effect)and with an additional fan to improve the performance.Fan• Adjustable base for roof slopes between 0 and 30%• Built in sheet aluminium with a stainless steel base toprevent corrosion• Impeller made from polyamideMotor:• Single-phase two-speed motors with IE-2efficiency, except lower powers 0.75 kW.• Class F motors with ball bearings,IP55 protection• Three-phase 230/400V – 50 Hz• Max. air temperature to transport:- 25ºC y +60ºCHTTAL 56 4TMixed roof fan withadjustable baseImpeller diameter (cm)Number of motor poles4=1400 r/min. 50 Hz6=900 r/min. 50 HzT= Three-phaseTechnical characteristicsModelSpeed(r/min)Maximum admissiblecurrent (A)230V 400VInstalledpower(kW)Maximumairflow(m 3 /h)Sound pressure Approx. weightlevel(Kg)dB(A)HTTAL-56-4T 1440 4.68 2.70 1.10 11700 72 44.00HTTAL-56-6T 940 2.25 1.30 0.37 7560 61 43.60HTTAL-71-4T 1450 6.06 3.50 1.50 18900 78 56.00HTTAL-71-6T 950 2.96 1.71 0.55 13500 61 55.00Dimensions in mmCharacteristic CurvesModel A B ØCHTTAL-56-4T 360 920x920 570HTTAL-56-6T 360 920x920 570HTTAL-71-4T 460 1150x1150 730HTTAL-71-6T 460 1150x1150 730AccessoriesSee accessories section.INT AR RFT/ RFM PANELS S111
- Page 60 and 61: HT/ATEXCharacteristic curvesQ = Air
- Page 62 and 63: CHT/ATEX CVT/ATEXAcoustic featuresT
- Page 64 and 65: CHT/ATEX CVT/ATEXCharacteristic cur
- Page 66 and 67: HCT/ATEX HFT/ATEXTechnical characte
- Page 68 and 69: HTPHTPCased high-pressure axial fan
- Page 70 and 71: HTPEXAMPLE OF SELECTIONCharacterist
- Page 72 and 73: HTPCharacteristic curvesQ = Airflow
- Page 74 and 75: HTPCharacteristic curvesQ = Airflow
- Page 76 and 77: HTPCharacteristic curvesQ = Airflow
- Page 78 and 79: HTPCharacteristic curvesQ = Airflow
- Page 80 and 81: HTPCharacteristic curvesQ = Airflow
- Page 82 and 83: HBADimensions in mmHBA-31...50HBA-6
- Page 84 and 85: CMP/MARTechnical characteristicsMod
- Page 86 and 87: CMP/MARCharacteristic curvesSee pag
- Page 88 and 89: CMPITechnical characteristicsModelS
- Page 90 and 91: CMPIDimensions in mmCMPI-1435...256
- Page 92 and 93: CMP/ATEX CMP/MAR CMPICharacteristic
- Page 94 and 95: CMP/ATEX CMP/MAR CMPICharacteristic
- Page 96 and 97: CMRGAcoustic featuresThe specified
- Page 98 and 99: CMRGDimensions in mmOutletCMR-1031C
- Page 101 and 102: CPVCPVCentrifugal anti-corrosive si
- Page 103 and 104: CPVDimensions in mmCPV-1160...2160M
- Page 105 and 106: CPVCharacteristic curvesQ = Airflow
- Page 107 and 108: HTMHTechnical characteristicsModelS
- Page 109: HTMHCharacteristic curvesQ = Airflo
- Page 113 and 114: HTSOLARDimensions in mmHTSOLAR-45HT
- Page 116 and 117: KITS DE SOBREPRESIÓNDimensions in
- Page 118 and 119: FANS FORWIND APPLICATIONSCMR/EOL HF
- Page 120 and 121: ACCESSORIESINTOn/off safety switche
- Page 122 and 123: ACCESSORIESKME - 10KFeatures:• On
- Page 124 and 125: ACCESSORIESRIProtection guard for o
- Page 126 and 127: ACCESSORIESBDFeatures:• Adapted t
- Page 128 and 129: ACCESSORIESAutomatic-closing shutte
- Page 130 and 131: 130ACCESSORIESL d1 d2 l d3 d4 d5 d6
- Page 132 and 133: ACCESSORIESIntelligent sensors for
- Page 134 and 135: Alphabetical index of references. F
- Page 136 and 137: OUR PRODUCTSIn-line duct fansAxial
- Page 138: Crta. de Berga, km 0.7E-08580 SANT
HTTALHTTALHTTALOrder code+Mixed (wind + dynamic) roof <strong>fans</strong>with adjustable baseRoof fan operating by means of natural convection(due to depression of hot air <strong>and</strong> the Venturi effect)<strong>and</strong> with an additional fan to improve the per<strong>for</strong>mance.Fan• Adjustable base <strong>for</strong> roof slopes between 0 <strong>and</strong> 30%• Built in sheet aluminium with a stainless steel base toprevent corrosion• Impeller made from polyamideMotor:• Single-phase two-speed motors with IE-2efficiency, except lower powers 0.75 kW.• Class F motors with ball bearings,IP55 protection• Three-phase 230/400V – 50 Hz• Max. air temperature to transport:- 25ºC y +60ºCHTTAL 56 4TMixed roof fan withadjustable baseImpeller diameter (cm)Number of motor poles4=1400 r/min. 50 Hz6=900 r/min. 50 HzT= Three-phaseTechnical characteristicsModelSpeed(r/min)Maximum admissiblecurrent (A)230V 400VInstalledpower(kW)Maximumairflow(m 3 /h)Sound pressure Approx. weightlevel(Kg)dB(A)HTTAL-56-4T 1440 4.68 2.70 1.10 11700 72 44.00HTTAL-56-6T 940 2.25 1.30 0.37 7560 61 43.60HTTAL-71-4T 1450 6.06 3.50 1.50 18900 78 56.00HTTAL-71-6T 950 2.96 1.71 0.55 13500 61 55.00Dimensions in mmCharacteristic CurvesModel A B ØCHTTAL-56-4T 360 920x920 570HTTAL-56-6T 360 920x920 570HTTAL-71-4T 460 1150x1150 730HTTAL-71-6T 460 1150x1150 730AccessoriesSee accessories section.INT AR RFT/ RFM PANELS S111