13.07.2015 Views

NTOMX-HHPJ-__-_ Hand-Held Programmer Jack - Lutron

NTOMX-HHPJ-__-_ Hand-Held Programmer Jack - Lutron

NTOMX-HHPJ-__-_ Hand-Held Programmer Jack - Lutron

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GRAFIK SYSTEMS<strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> <strong>Jack</strong><strong>NTOMX</strong>-<strong>HHPJ</strong>COLOR AND FINISH CODES<strong>NTOMX</strong>-<strong>HHPJ</strong>-__-_<strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> <strong>Jack</strong>DESCRIPTIONThis jack connects the GR6HHP <strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> toGRAFIK 5000/6000 Systems:• The jack sits on a Wallstation Link that connects to theProcessor Panel.• The <strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> plugs into the jack.rev hhpj-1a 7.27.00Put <strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> <strong>Jack</strong>s wherever you have Wallstations,so you can plug in the <strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> to adjust scenesand zones “on location.”Standard engravingSPECIFICATIONSPowerOperating voltage: Low-voltage Class 2 (PELV), 32VDC.Key Design Features• Meets IEC 801-2. Tested to withstand 15kV electrostatic dischargewithout damage or memory loss.• Has faceplate that snaps on with no visible means of attachment.System Communications and Capacity• Low-voltage Class 2 (PELV) wiring connects jack to Processor Panel.• As many jacks as you want – <strong>Jack</strong>s have no address and don’tcount as one of the 32 Wallstations, Control Units, or ControlInterfaces allowed on a Wallstation Link.TerminalsCapacity: Two #18 AWG (1.0mm 2 ).Environment32 - 104°F (0 - 40°C). 90% non-condensing relative humidity.The <strong>Jack</strong> Connects the <strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong> to the SystemGR6-HHP <strong>Hand</strong>-<strong>Held</strong><strong>Programmer</strong>GRAFIK 5000/6000Processor PanelControl UnitControl Interface<strong>Programmer</strong><strong>Jack</strong><strong>NTOMX</strong>-<strong>HHPJ</strong><strong>Hand</strong>-<strong>Held</strong><strong>Programmer</strong><strong>Jack</strong>Class 2 (PELV) Wallstation Link® SPECIFICATION SUBMITTALPageJOB NAME:MODEL NUMBERS:JOB NUMBER:


GRAFIK SYSTEMSCOLOR AND FINISH CODESMatte FinishesWhite WHIvoryIVBeigeBEGrayGRBrown BRBlackBLMetal FinishesBright Brass BBBright Chrome BCBright Nickel BNSatin Brass SBSatin Chrome SCSatin Nickel SNAntique Brass QBAntique Bronze QZAnodized AluminumClear CLABlack BLABrass BRADIMENSIONSFront ViewMOUNTINGWALLSTATIONSClass 2 (PELV) wiringSide ViewSpecifications and Mountingrev hhpj-2a 7.27.00Custom Controls, color matching, andengraving available. Pricing and leadtime may vary depending on colors,finishes, and options chosen.DELIVERYShips in 4 to 6 weeks depending onsystem delivery.1 GangU.S. WallboxFaceplateWIRING• Daisy-chain the <strong>Hand</strong>-<strong>Held</strong> <strong>Programmer</strong><strong>Jack</strong> onto the low-voltageClass 2 (PELV) Wallstation Link.• Make all connections in the programerjack’s wallbox. Or in a switchbox or junctionbox with a maximum wire length of 8feet (2.5m) from the link to the jack.• Consult the Processor Panel SpecificationSubmittal for more details.CLASS 2 (PELV)JACK’S WIRE TERMINAL WIRINGCONNECTIONBlack(or white)RedYellowBlue1: Common2: 32VDC3: MUX4: MUX• Two #12 AWG (2.5mm2) conductors.• One shielded, twisted pair #18 AWG (1.0mm 2 ) for data link.• Connect Drain/Shield as shown in Wallstation Wiring.• Do not connect to Ground (Earth) or jack.• Connect the bare drain wires and cut off the outside shield.® SPECIFICATION SUBMITTALPageJOB NAME:MODEL NUMBERS:JOB NUMBER:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!