Pocket PC Maintenance1 2 3Figure 2G-22: Standards Screens: (1) ASM 5015, (2) ASM 2525, and (3) IM240New NO x SensorNew NO x sensor procedure is required when the cell is replaced, however periodicrecalibration is necessary as prompted during the normal Gas Calibration sequence(see Resetting NO x Cell Output Voltage, page 2G-6). Perform a new NO x sensorinitialization whenever the NO x sensor is replaced, which should only be done byqualified personnel or when the NO x warning appears.To perform a new NO x sensor initialization,1. Press the Maintenance button on the main menu.— The Maintenance menu displays.2. Choose Setup.— The Setup menu displays.3. Choose New NO x .— The NO x Sensor Initialization screen displays.2G-18
Pocket PC MaintenanceFigure 2G-23: NO x Sensor Initialization Screen4. Make sure the exhaust hose is connected to the exhaust port.5. Select Start to begin NO x sensor initialization.The procedure then followed is the conventional gas calibration procedure.See Gas Calibration, page 2G-1.If the new NO x sensor initialization fails,Figure 2G-24: NO x Sensor Initialization Fail Screen1. Verify that the gauge(s) read at least 30 psi.2. Verify that the gas bottle is properly attached.3. Re-run the new NO x sensor initialization.4. Check the calibration gas bottle values.2G-19
- Page 31 and 32: Pocket PC Software Installation3. F
- Page 33 and 34: Pocket PCMeters/Graph2CThis chapter
- Page 35 and 36: Pocket PC Meters/GraphStrip ChartTo
- Page 37 and 38: Pocket PC Meters/GraphBar GraphTo b
- Page 39 and 40: Pocket PC Meters/GraphConfiguration
- Page 41 and 42: Pocket PC Meters/GraphResultsThe po
- Page 43 and 44: Pocket PCAutomatic Tests2DTSI TestT
- Page 45 and 46: Pocket PC Automatic TestsHigh RPM T
- Page 47 and 48: Pocket PC Automatic TestsTest Compl
- Page 49 and 50: Pocket PC Automatic TestsCatalyst T
- Page 51 and 52: Pocket PC Automatic Tests5. When pr
- Page 53 and 54: Pocket PC Automatic TestsIf the res
- Page 55 and 56: Pocket PCCustomer/Vehicle2EFGA is d
- Page 57 and 58: Pocket PC Customer/Vehicle✓ To di
- Page 59 and 60: Pocket PC Customer/Vehicle2. Choose
- Page 61 and 62: 2FPocket PC ResultsTest ResultsThe
- Page 63 and 64: Pocket PC ResultsChange StandardsCu
- Page 65 and 66: Pocket PCMaintenance2GThis section
- Page 67 and 68: Pocket PC Maintenance6. Press OK to
- Page 69 and 70: Pocket PC MaintenanceIf the reading
- Page 71 and 72: Pocket PC Maintenance✓ Always mak
- Page 73 and 74: Pocket PC Maintenance3. Remove the
- Page 75 and 76: Pocket PC MaintenanceSetupThis sect
- Page 77 and 78: Pocket PC MaintenanceRPM/Temp Kit
- Page 79 and 80: Pocket PC MaintenanceTSI / Idle Set
- Page 81: Pocket PC MaintenanceStandardsThe S
- Page 85 and 86: Pocket PC MaintenanceBoard Diagnost
- Page 87 and 88: Pocket PC MaintenanceTo perform the
- Page 89 and 90: Pocket PC Maintenance7. Press the S
- Page 91 and 92: Pocket PC MaintenanceFigure 2G-34:
- Page 93 and 94: Pocket PC MaintenanceLow Out FlowTh
- Page 95 and 96: Pocket PCOther Functions2HAboutThis
- Page 97 and 98: 3Using FGA with the PCThe Flexible
- Page 99 and 100: 3APC Software OverviewThe PC versio
- Page 101 and 102: PC Software OverviewCommands 1-10Co
- Page 103 and 104: PC Software OverviewCommandsFigure
- Page 105 and 106: 3BPC SoftwareInstallationThe Flexib
- Page 107 and 108: PC Software Installation5. If this
- Page 109 and 110: 3CPC Meters/Strip ChartThis chapter
- Page 111 and 112: PC Meters/GraphGas Bench MenuThe Ga
- Page 113 and 114: PC Meters/GraphStrip ChartTo view t
- Page 115 and 116: PC Meters/GraphStrip Chart Display
- Page 117 and 118: PC Meters/GraphWhen you select the
- Page 119 and 120: PC Meters/GraphTachometerUse the Ta
- Page 121 and 122: PC Automatic Tests3DTSI TestThis se
- Page 123 and 124: PC Automatic TestsTachometer Config
- Page 125 and 126: PC Automatic TestsIdle RPM TestFGA
- Page 127 and 128: PC Automatic TestsTSI Results16. Th
- Page 129 and 130: 3EPC Customer/VehicleFGA is designe
- Page 131 and 132: PC Customer/VehicleInformation bar
Pocket PC MaintenanceFigure 2G-23: NO x Sensor Initializati<strong>on</strong> Screen4. Make sure the exhaust hose is c<strong>on</strong>nected to the exhaust port.5. Select Start to begin NO x sensor initializati<strong>on</strong>.The procedure then followed is the c<strong>on</strong>venti<strong>on</strong>al gas calibrati<strong>on</strong> procedure.See Gas Calibrati<strong>on</strong>, page 2G-1.If the new NO x sensor initializati<strong>on</strong> fails,Figure 2G-24: NO x Sensor Initializati<strong>on</strong> Fail Screen1. Verify that the gauge(s) read at least 30 psi.2. Verify that the gas bottle is properly attached.3. Re-run the new NO x sensor initializati<strong>on</strong>.4. Check the calibrati<strong>on</strong> gas bottle values.2G-19