PC Meters/GraphMenusFigure 3C-1: Manual Meters ScreenYou can change the value displayed in any meter box by using the drop-downmenu at the bottom of each box. Simply select the arrow to view the menu andchoose the value you want to display in that meter box.The Manual Meters screen contains three menus and a set of buttons:• Test Actions• Gas Bench• Tachometer• ButtonsTest Actions MenuThe Manual Meters Test Actions menu, top left on the Manual Meters screen,contains a save command, several commands that control recording and acommand to switch to the strip chart display.Save—Saves all values and displays them on the Single Save tab of the TestResults window. See the section below titled Manual Meters / Strip Chart Results.Start Recording—Begins recording all signals. The system stores all valuesduring the recording period.Pause—You can select Pause at any time. The Pause menu item suspends valuesfrom being updated, in effect it freezes the screen. If a recording is in progress, italso suspends recording. Select Pause a second time to resume.Stop Recording—The Stop Recording menu item is enabled only when arecording is in progress. Stop Recording ends the recording. When you selectStop Recording, the results of the recording are displayed in the Test Resultswindow. See the section below titled Manual Meters / Strip Chart Results.Strip Chart—Displays the Strip Chart view (discussed in the Strip Chart section).3C-2
PC Meters/GraphGas Bench MenuThe Gas Bench menu, top left on the Manual Meters screen, contains commandsthat control gas bench settings.Pump On—Turns the gas bench pump on or off. A check next to Pump Onindicates that the pump is on, no check indicates the pump is off.Zero—Activates the Gas Bench Zero process. Use this command if you want toverify that the analyzer reads properly when there is no gas present in the samplecell.✓ To perform an Auto Zero, the probe must be out of the tailpipe samplingfresh air.Fuel Type—Notifies the system what type of fuel the vehicle burns, which is usedto calculate the Dilution Correction Factor (DCF). The setting defaults to Gasolinebut you can select the appropriate vehicle fuel type. A check to the left of the fuelindicates the fuel type selected.GasolineMethanol / EthanolCompressed Natural GasLiquid Propane GasRefresh Rate—Contains settings for the Manual Meters display.Instantaneous (Default)— Displays readings as they happen5 Second Rolling Average— Calculates and displays an average every 5 seconds. (California ASMmandated averaging)Tachometer MenuThe Tachometer menu, top left on the Manual Meters screen, contains a singlecommand to set up the tachometer.The Setup command opens the Tachometer Configuration window.3C-3
- Page 59 and 60: Pocket PC Customer/Vehicle2. Choose
- Page 61 and 62: 2FPocket PC ResultsTest ResultsThe
- Page 63 and 64: Pocket PC ResultsChange StandardsCu
- Page 65 and 66: Pocket PCMaintenance2GThis section
- Page 67 and 68: Pocket PC Maintenance6. Press OK to
- Page 69 and 70: Pocket PC MaintenanceIf the reading
- Page 71 and 72: Pocket PC Maintenance✓ Always mak
- Page 73 and 74: Pocket PC Maintenance3. Remove the
- Page 75 and 76: Pocket PC MaintenanceSetupThis sect
- Page 77 and 78: Pocket PC MaintenanceRPM/Temp Kit
- Page 79 and 80: Pocket PC MaintenanceTSI / Idle Set
- Page 81 and 82: Pocket PC MaintenanceStandardsThe S
- Page 83 and 84: Pocket PC MaintenanceFigure 2G-23:
- Page 85 and 86: Pocket PC MaintenanceBoard Diagnost
- Page 87 and 88: Pocket PC MaintenanceTo perform the
- Page 89 and 90: Pocket PC Maintenance7. Press the S
- Page 91 and 92: Pocket PC MaintenanceFigure 2G-34:
- Page 93 and 94: Pocket PC MaintenanceLow Out FlowTh
- Page 95 and 96: Pocket PCOther Functions2HAboutThis
- Page 97 and 98: 3Using FGA with the PCThe Flexible
- Page 99 and 100: 3APC Software OverviewThe PC versio
- Page 101 and 102: PC Software OverviewCommands 1-10Co
- Page 103 and 104: PC Software OverviewCommandsFigure
- Page 105 and 106: 3BPC SoftwareInstallationThe Flexib
- Page 107 and 108: PC Software Installation5. If this
- Page 109: 3CPC Meters/Strip ChartThis chapter
- Page 113 and 114: PC Meters/GraphStrip ChartTo view t
- Page 115 and 116: PC Meters/GraphStrip Chart Display
- Page 117 and 118: PC Meters/GraphWhen you select the
- Page 119 and 120: PC Meters/GraphTachometerUse the Ta
- Page 121 and 122: PC Automatic Tests3DTSI TestThis se
- Page 123 and 124: PC Automatic TestsTachometer Config
- Page 125 and 126: PC Automatic TestsIdle RPM TestFGA
- Page 127 and 128: PC Automatic TestsTSI Results16. Th
- Page 129 and 130: 3EPC Customer/VehicleFGA is designe
- Page 131 and 132: PC Customer/VehicleInformation bar
- Page 133 and 134: PC Customer/VehicleWhen the desired
- Page 135 and 136: 3FPC ResultsThe Test Results window
- Page 137 and 138: 3GPC MaintenanceGas CalibrationThis
- Page 139 and 140: PC Maintenance5. Attach the calibra
- Page 141 and 142: PC MaintenanceNew NO x SensorNew NO
- Page 143 and 144: PC MaintenanceShop InformationThe S
- Page 145 and 146: PC MaintenanceThe Setup window cont
- Page 147 and 148: PC MaintenanceTSI Test SetupThe TSI
- Page 149 and 150: PC MaintenanceZero Purge Time(s)—
- Page 151 and 152: PC MaintenanceDiagnosticsService ut
- Page 153 and 154: PC Other Functions3HThis chapter co
- Page 155 and 156: 4General MaintenanceThis chapter ad
- Page 157 and 158: General MaintenanceOptionsPart Numb
- Page 159 and 160: General Maintenance3. Select the Ig
PC Meters/GraphMenusFigure 3C-1: Manual Meters ScreenYou can change the value displayed in any meter box by using the drop-downmenu at the bottom of each box. Simply select the arrow to view the menu andchoose the value you want to display in that meter box.The Manual Meters screen c<strong>on</strong>tains three menus and a set of butt<strong>on</strong>s:• Test Acti<strong>on</strong>s• Gas Bench• Tachometer• Butt<strong>on</strong>sTest Acti<strong>on</strong>s MenuThe Manual Meters Test Acti<strong>on</strong>s menu, top left <strong>on</strong> the Manual Meters screen,c<strong>on</strong>tains a save command, several commands that c<strong>on</strong>trol recording and acommand to switch to the strip chart display.Save—Saves all values and displays them <strong>on</strong> the Single Save tab of the TestResults window. See the secti<strong>on</strong> below titled Manual Meters / Strip Chart Results.Start Recording—Begins recording all signals. The system stores all valuesduring the recording period.Pause—You can select Pause at any time. The Pause menu item suspends valuesfrom being updated, in effect it freezes the screen. If a recording is in progress, italso suspends recording. Select Pause a sec<strong>on</strong>d time to resume.Stop Recording—The Stop Recording menu item is enabled <strong>on</strong>ly when arecording is in progress. Stop Recording ends the recording. When you selectStop Recording, the results of the recording are displayed in the Test Resultswindow. See the secti<strong>on</strong> below titled Manual Meters / Strip Chart Results.Strip Chart—Displays the Strip Chart view (discussed in the Strip Chart secti<strong>on</strong>).3C-2