13.07.2015 Views

IQLVAV/xxx, ../VAV LonMark Terminal Unit Controllers Installation ...

IQLVAV/xxx, ../VAV LonMark Terminal Unit Controllers Installation ...

IQLVAV/xxx, ../VAV LonMark Terminal Unit Controllers Installation ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>IQL<strong>VAV</strong></strong>/<strong>xxx</strong>, ../<strong>VAV</strong><strong>Installation</strong> Instructions3.2 <strong>Installation</strong> - Configuration (continued)25Set up IC Comms from IQLif requiredUse IqlTool2 (see section 3.2 step 12) and text communicationsIC Comms Module Nx(.. - (x=1 to y; y=4 for standard strategies)ParameterFunctionA - Remote device addressIf zero, 'global to' comms. If non-zero specifiestarget device address for 'data to' commsFor 'global to' comms only, attribute of target IQ,B - Attributereferences attribute in address module (0 'noattribute', - all IQs on Lan,1 'identifier', 2 'attribute2', 3 'attribute 3')N - Remote LanTarget IQ Lan number; if Lan zero, address zero,specifies global globalI - IntervalInterval between sending (minutes)S - Significant change Amount analogue must change before sendingM - Source item string Item and parameter being sent (e.g. S1(V) )E - Destination module number No. of destination module receiving IC commsT - Destination typeType of destn module receiving comms (e.g. W,K)LonWorksLCI<strong>IQL<strong>VAV</strong></strong>S1S8K1K2K8I1I8W1W7W8NxNxIC CommsLINCIQ26IC Comms ‘direction’ in IQ must be:Global To, Min, Max, Sum, or Average(directions 2 to 6)LonWorksSet up IC Comms from IQif requiredsee IQ ConfigurationManual 90-1533Use PowerTool or Wupdn and terse textcommunications27LonWorksSet up Text Communicationsfrom Supervisorif requirede.g. 963 (drag and dropvalues)Note that standard strategy pagesare available for 963 from Partnernet<strong>IQL<strong>VAV</strong></strong>S1Terse Text CommsLINC4 Disposal<strong>IQL<strong>VAV</strong></strong>S1S16A1A16K1 A17K8 A24I1 B1,0I16 B2,7W1 B18,0W8 B19,7LINCNxNxIQIC CommsWEEE Directive :K1K2K8I1S8I8W1W7W8IQNote that any changesto the strategyparameters shouldimmediately befollowed by a write tothe address module, [text comms command, R(z=0),recommended], to commit changes to flash memory.At the end of their useful life the packagin and product should be disposed ofby a suitable recycling centre.Do not dispose of with normal household waste. Do not burn.Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Routedu Bois 37,Switzerland by its Authorized Representative, Trend Control Systems Limited.Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereofwithout obligation to notify any person of such revisions or changes.Trend Control Systems LimitedP.O. Box 34, Horsham, West Sussex, RH12 2YF, UK. Tel:+44 (0)1403 21888 Fax:+44 (0)1403 241608 www.trend-controls.comTrend Control Systems USA6670 185th Avenue NE, Redmond, Washington 98052, USA. Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com12<strong>IQL<strong>VAV</strong></strong>/<strong>xxx</strong>, ../<strong>VAV</strong> <strong>Installation</strong> Instructions TG200704 Issue 2/D 22/08/07

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!