Property_Manu - Final - The New India Assurance Co. Ltd.
Property_Manu - Final - The New India Assurance Co. Ltd.
Property_Manu - Final - The New India Assurance Co. Ltd.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>The</strong> <strong>New</strong> <strong>India</strong> <strong>Assurance</strong> <strong>Co</strong>.<strong>Ltd</strong>.STEP - 4INSPECTION COMMITTEE- FUNCTIONi. RO Inspection <strong>Co</strong>mmittee specifically formed for this purpose by Chief Regional Manager/Deputy General Manager should consist of :-1. Regional-In-Charge/ Manager or Deputy Manager in Charge of the department.2. <strong>Co</strong>mpany’s Engineer (where available)3. An officer from Internal Audit Department, RO.4. <strong>Co</strong>ncerned Divisional Manager5. <strong>Co</strong>ncerned Branch Manager, if applicable.ii.iii.iv.<strong>The</strong> Inspection <strong>Co</strong>mmittee should inspect all the short-listed premises within 7 DAYSfrom the date of opening of “Technical Bid”.Before inspection of the short-listed premises prior intimation should be given to thelandlords fixing the date & time for inspection by the Inspection <strong>Co</strong>mmittee.<strong>The</strong> Landlords should be advised to produce following original documents at the time ofinspection:1. Title deed of the premises2. Supporting documents for commercial use of the premises wherever applicable,3. Sanctioned plan & Occupancy Certificate4. Fire Safety Certificate (in case of Multi-storied building).v. It is reiterated here that the selection of the new premises has to be done under 2 bidssystem and the opening of “Financial Bids” depends on the re-commendation for apremise which should be in absolute terms (e.g. the premises is reasonably suitable,hence “RECOMMENDED”), thereby leaving no rooms for any ambiguity/ confusion inthe matter of opening of the related “Financial Bid” by the Tender <strong>Co</strong>mmittee. <strong>The</strong>reforethe <strong>Co</strong>mmittee should avoid recommendations like “this premises is most suitablepremises.” What is expected from the <strong>Co</strong>mmittee is to state in categorical terms whetheror not the premises falls within acceptable parameters. <strong>The</strong> recommendation for premisesshould also not be in any order of preference.vi.REJECTION: - If a premise is found unsuitable, the reasons should be clearly mentionedin the report. For example writing, “Rejected because the premises is not situated inMANUAL ON PROPERTY15