13.4 P121 SELECTOR SWITCH SETTINGSTo enable the P121 analogue AVR interface module to interface with as many different types ofAVR as possible, rotary selectors for voltage range and nominal voltage are fitted. These allow theuser to configure the output of the module to match the input of the AVR.13.4.1 SW1The SW1 selector sets the ‘centre’ point of the interface module’s output. For example: if the outputrange required is 1V to 3V, with the ‘centre’ point being at 2V, then the position of the SW1 selectorwould be 4, giving a voltage offset of 2V.13.4.2 SW2The SW2 selector sets the voltage output range of the interface module’s output. For example: ifthe output range required is 1V to 3V, then the position of the SW2 selector would be 1, giving avoltage range of ±1V from the ‘centre’ point of 2V13.4.3 SW1 / SW2 SELECTOR SETTINGS.For reference purposes, the switch positions perform the following functions:SW1 setting ‘centre’ voltage of P121 SW2 setting Voltage range of P1210 0V 0 ±0.5V1 0.5V 1 ±1.0V2 1.0V 2 ±1.5V3 1.5V 3 ±2.0V4 2.0V 4 ±2.5V5 2.5V 5 ±3.0V6 3.0V 6 ±3.5V7 3.5V 7 ±4.0V8 4.0V 8 ±4.5V9 4.5V 9 ±5.0VTypical wiring diagrams for many of the most popular AVRs are included within this manual (Seesection entitled Interfacing to AVRs).Where these diagrams include the P121 interface modules, the switch positions required for bothSW1 and SW2 are given.NOTE: - If the AVR you are using is not listed within this manual, it may still be possibleto interface to it using the P121 modules. Contact your AVR manufacturer to check if theproduct has a DC voltage input for connection to a synchroniser / load sharer, and if so,what the ‘voltage range’ and ‘centre voltage’ is. You can then use the tables above todetermine settings for SW1 and SW2. P121 terminal A is the negative output terminal andB is the positive output terminal (providing governor output reversed is not selected in the55x controller’s configuration).If the ‘centre voltage’ and ‘voltage range’ are not available from the AVR manufacturer,providing the input is compatible with a DC voltage signal, it still may be possible tointerface to it using the P121 modules. Contact our Technical Support Department foradvice.If the AVR is not fitted with a DC voltage input for connection to synchroniser/load sharemodules, then a different interface method will be required. See section entitledInterfacing to AVRs.DSE Guide to Synchronising & Load Sharing PART 1 ISSUE5 18/3/04 AM 37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!