H100B Pulse Oximeter User Manualsystem for seconds (the pause period can be set to 30, 60,90 or 120s by the user, see section 3.3.5), the audioalarm off icon displays. But the visual alarm is stillactive. For example, if the measured SpO 2 value ishigher than SpO 2 Hi Alarm or lower than SpO 2 LoAlarm, there will be↑or↓icon displayed on screen, andthe SpO 2 or PR character will flash.If Alarm system is set to OFF, all audio alarms andvisual alarms are turned off.WARNINGWhen the Alarm system is off, the oximeter will notgive an alarm prompt. In order to avoid endangeringthe patient’s life, the user should use this functioncautiously.3.3.10 SpO 2 Alarm SetupThe user can choose SpO 2 Hi Alarm and SpO 2 LoAlarm in menu to adjust SpO 2 alarm limit. Press the UpArrow button or Down Arrow button to increase ordecrease alarm limit.By default, SpO 2 Hi Alarm and SpO 2 Lo Alarm in Neo- 44 -
H100B Pulse Oximeter User Manualmode are set to 95 and 90 respectively; while they are100 and 90 in Adu mode respectively.Set the SpO 2 alarm limits as follows: Choose SpO 2 Hi Alarm in the menu, press theFunction button to enter setup. The SpO 2 HiAlarm box will change from real line box tobroken line box. The adjustable range forupper limit of SpO 2 is from “1 + the lowerlimit of SpO 2 ” to 100. If the value of SpO2 HiAlarm is set to less than 85, it will restore todefault value after the oximeter is turned onagain. In the NEO mode, if the value of SpO2Hi Alarm is set to higher than 95, it willrestore to 95 after the oximeter is turned onagain. Press the Up Arrow or Down Arrow button toincrease or decrease values. Choose SpO 2 Lo Alarm in the menu, press theFunction button to set it. The SpO 2 Lo Alarmbox will change from real line box to brokenline box. The adjustable range for the lowerlimit of SpO 2 Alarm is from 0 to “the upper- 45 -
- Page 2 and 3: About this ManualP/N: 21.54.109000-
- Page 4 and 5: qualified technician to maintain an
- Page 6 and 7: 3.3 System Menu ...................
- Page 8 and 9: A1.1 Classification................
- Page 10 and 11: H100B Pulse Oximeter User Manualsen
- Page 12 and 13: H100B Pulse Oximeter User Manualfal
- Page 14 and 15: H100B Pulse Oximeter User Manualman
- Page 16 and 17: H100B Pulse Oximeter User Manualwas
- Page 18 and 19: H100B Pulse Oximeter User Manual•
- Page 21 and 22: H100B Pulse Oximeter User ManualThe
- Page 23 and 24: H100B Pulse Oximeter User ManualFig
- Page 25 and 26: H100B Pulse Oximeter User ManualSpO
- Page 28 and 29: or off the backlight.H100B Pulse Ox
- Page 30 and 31: H100B Pulse Oximeter User Manualthe
- Page 32 and 33: H100B Pulse Oximeter User Manual1 R
- Page 34 and 35: H100B Pulse Oximeter User ManualChe
- Page 36 and 37: H100B Pulse Oximeter User ManualQua
- Page 38 and 39: H100B Pulse Oximeter User ManualRS2
- Page 40 and 41: H100B Pulse Oximeter User ManualFig
- Page 42 and 43: H100B Pulse Oximeter User ManualArr
- Page 44 and 45: H100B Pulse Oximeter User ManualMan
- Page 46 and 47: H100B Pulse Oximeter User ManualFig
- Page 48 and 49: H100B Pulse Oximeter User ManualPul
- Page 50 and 51: H100B Pulse Oximeter User ManualA d
- Page 54 and 55: H100B Pulse Oximeter User Manuallim
- Page 56 and 57: H100B Pulse Oximeter User ManualAft
- Page 58 and 59: H100B Pulse Oximeter User Manual3.3
- Page 60 and 61: H100B Pulse Oximeter User Manual4 A
- Page 62 and 63: H100B Pulse Oximeter User ManualUnc
- Page 64 and 65: H100B Pulse Oximeter User Manualgiv
- Page 66 and 67: H100B Pulse Oximeter User Manual5 P
- Page 68 and 69: H100B Pulse Oximeter User Manual Pl
- Page 70 and 71: H100B Pulse Oximeter User Manual Ve
- Page 72 and 73: H100B Pulse Oximeter User Manual In
- Page 74 and 75: H100B Pulse Oximeter User Manual7 P
- Page 76 and 77: H100B Pulse Oximeter User ManualThe
- Page 78 and 79: H100B Pulse Oximeter User Manual7.3
- Page 80 and 81: H100B Pulse Oximeter User Manualrep
- Page 82 and 83: H100B Pulse Oximeter User ManualApp
- Page 84 and 85: H100B Pulse Oximeter User ManualCap
- Page 86 and 87: H100B Pulse Oximeter User ManualApp
- Page 88 and 89: H100B Pulse Oximeter User ManualA2.
- Page 90 and 91: H100B Pulse Oximeter User ManualPow
- Page 92 and 93: H100B Pulse Oximeter User Manualtha
- Page 94 and 95: H100B Pulse Oximeter User Manualfre
- Page 96 and 97: H100B Pulse Oximeter User Manual(W)
- Page 98: H100B Pulse Oximeter User ManualApp
H100B Pulse Oximeter User <strong>Manual</strong>mode are set to 95 and 90 respectively; while they are100 and 90 in Adu mode respectively.Set the SpO 2 alarm limits as follows: Choose SpO 2 Hi Alarm in the menu, press theFunction button to enter setup. The SpO 2 HiAlarm box will change from real line box tobroken line box. The adjustable range forupper limit of SpO 2 is from “1 + the lowerlimit of SpO 2 ” to 100. If the value of SpO2 HiAlarm is set to less than 85, it will restore todefault value after the oximeter is turned onagain. In the NEO mode, if the value of SpO2Hi Alarm is set to higher than 95, it willrestore to 95 after the oximeter is turned onagain. Press the Up Arrow or Down Arrow button toincrease or decrease values. Choose SpO 2 Lo Alarm in the menu, press theFunction button to set it. The SpO 2 Lo Alarmbox will change from real line box to brokenline box. The adjustable range for the lowerlimit of SpO 2 Alarm is from 0 to “the upper- 45 -