Simplify with Quanti-Tray®/2000 - IDEXX Laboratories

Simplify with Quanti-Tray®/2000 - IDEXX Laboratories

Simplify with Quanti-Tray®/2000 - IDEXX Laboratories

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Don’t pour all your efforts into multiple-tube fermentation• Media QC• Glassware• Pipetting• Odor• Serial dilution• Coliform Presumptive• Tube Labeling• Turbid no gas• Buffered water• Autoclave• 35˚C and 44.5˚C• 15–45 tubes/sample• EC Media, BGB, LTB®<strong>Simplify</strong> <strong>with</strong> <strong>Quanti</strong>-Tray /<strong>2000</strong>


®<strong>Quanti</strong>-Tray /<strong>2000</strong>Easy• No colony counting required• No dilutions needed forcounts up to 2,419• No media preparationor confirmation• 15-minute QC procedureRapid• Coliform and E. coli results in18 hours <strong>with</strong> Colilert ® -18 or24 hours <strong>with</strong> Colilert ® or Colisure ®• Enterococci results in 24 hours<strong>with</strong> Enterolert• Confirmation not necessaryAccurate• Detection down to one organism/100 mL• Heterotrophic interference minimized• Better 95% confidence limitsthan multiple-tube fermentationand membrane filtrationTest Procedure1 2Add reagent tosampleAdd sample reagentto trayScientific BasisSeal tray andincubateCount positivewells and refer toMPN table<strong>Quanti</strong>-Tray/<strong>2000</strong>’s dual-well-size design takes advantage of the sameprobability model that a serial dilution MPN procedure uses. The largewells act as undiluted subsamples; the small wells as diluted subsamples.However, no diluent is required.<strong>Quanti</strong>-Tray/<strong>2000</strong>’s 97 wells result in a very high counting range (1 to 2,419)and very precise 95% confidence limits. The limitations of multiple-tubefermentation—lots of hands-on time, low counting range and broad 95%confidence limits—become strengths <strong>with</strong> <strong>Quanti</strong>-Tray ® and <strong>Quanti</strong>-Tray/<strong>2000</strong>:little hands-on time, high counting range and narrow 95% confidence limits.1:1342,419Cost-Effective• 70% less equipment costscompared to membrane filtration• Less than one minute hands-on timereduces labor costs• Media preparation not required• No repeat testing due to cloggedfilters or heterotrophic interference1:101:100diluentsample(no diluent needed)sample1,60015-TubeSerial Dilution<strong>Quanti</strong>-Tray/<strong>2000</strong><strong>Quanti</strong>-Tray/<strong>2000</strong> has 97 wells,resulting in a very high counting rangeup to 2,419 organisms/100 mL.For more information visit www.idexx.com/wateror in the U.S. and Canada, call 1-800-321-0207.Manufactured under one or more of the following U.S. Patents: 4,925,789; 5,429,933; 5,518,892; 5,610,029;5,620,865; 5,620,895; 5,753,456; and 5,780,259. Other U.S. and/or foreign patents issued or pending.<strong>Quanti</strong>-Tray, Colilert, Colisure and Enterolert are trademarks or registered trademarksof <strong>IDEXX</strong> <strong>Laboratories</strong>, Inc. in the United States and/or other countries.© 2010 <strong>IDEXX</strong> <strong>Laboratories</strong>, Inc. All rights reserved.• 09-60139-04<strong>IDEXX</strong> <strong>Laboratories</strong>, Inc., One <strong>IDEXX</strong> DriveWestbrook, Maine 04092 USA • www.idexx.com/waterTel: 1-207-556-4496 or 1-800-321-0207, Fax: 1-207-556-4630

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!