12. Appendix: Error messages and their elimination7. "Volume flow too low / too high"Description: Violation of lower/upper volume flow range limit valueCauses: • Volume flow limit values incorrectly programmed Elimination: • Check/correct limit value input• Volume flow setting on measuring device altered • Check actual value on measuring device, correct with regulating valve ifnecessary• Obstruction of sampling probe/sampling line (dust concentration influe gas > 50 mg / m 3 , even if these concentrations only occur over aperiod of approx. 30 minutes)• Check system for leaks• Particle protection filter at measuring gas input of Hg photometersoiled• Replace particle protection filter (round filter) on Hg photometer• Maintenance requirement for vacuum pump (M2) • Replace wearing parts on vacuum pump8. "System pressure too low / too high"Description: Violation of lower/upper system pressure range limit valueCauses: • Differential pressure nozzle obstructed Elimination: • Clean differential pressure nozzle• Volume flow error • See error elimination under 7• Energy supply for absolute pressure transducer (B3) interrupted • Activate automatic cutout F7 (find cause of F7 tripping), test miniaturefuse on power supply module (T1) (red LED must illuminate) and replaceif necessary9. "Threshold value exceeded"Description: Limit value violation, threshold value limit exceededCauses: • System-related increase in Hg concentration (operator) Elimination: • Eliminate system-related causes (operator)• Soiling of gas duct components • Locate component(s) at fault and clean if necessary10. "Condensate in monitor"Description: Moisture indicated by sensor contacts in condensate monitor and status message from level controller (condensate detector) (A4) to PLCCauses: • Energy supply for condensate detector (A4) interrupted Elimination: • Activate automatic cutout F7 (find cause of F7 tripping), test miniature fuseon power supply module (T1) (red LED must illuminate) and replace ifnecessary• <strong>Gas</strong> sample cooling (gas drying) is not operating correctly • See error elimination under 4• Condensate hose pump not operating or condensate hose oncondensate pump damaged• Activate automatic cutout F6 (find cause of F6 tripping), check functioningof hose pump, replace condensate pump hose if necessary84 <strong>HM</strong> <strong>1400</strong> <strong>TRX</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!