#1 _ 1-55 COMPRESSOR SECTION 2011 TOTALINE ...
#1 _ 1-55 COMPRESSOR SECTION 2011 TOTALINE ... #1 _ 1-55 COMPRESSOR SECTION 2011 TOTALINE ...
Compressors, Chillers & CondensersCompressors,Chillers, CondensersNON-CARLYLE HERMETIC COMPRESSORSGUIDE TO PART NUMBERING SYSTEM:MotorsExample:P 040 - 1 8 5 7 1ElectricalPARTSCAPACITY(1000) BTUH/HR LARGE UNITSNUMERICALSEQUENCEPART CODE030 - GOLDSTAR031 - TECUMSEH032 - BRISTOL033 - DAEWOO034 - MATSUSHITA/PANASONIC035 - TOSHIBA036 - SANYO037 - MITSUBISHI038 - HITACHI039 - DELCHI040 - MANEUROP050 - COPELAND 50HZ051 - TECUMSEH 50HZVOLTS0 - 115/11 - 200/12*- 208-230/1-60 or220/240-1-503 - 230/14 - 200/35* 208-230/3-60 or220/240-3-506 - 230/37 - 460/38 - 575/39 - MISC265/1277/1* Different Prefix used for 50 HzSee Part Code Column.Tools &InstrumentsHeatingComponentsThermostatsOils &ChemicalsAccessories, Supplies& CommoditiesRefrigerationIndoor AirQualityB-13
Compressors, Chillers & CondensersBRISTOLCOMPRESSOR MODEL NUMBER SYSTEMBristol Serial Number System:Bristol Serial Number System:H 2 9 B 1 9 U A B C ACompressors,Chillers, CondensersFamilyA= Model A ReciprocatingB= Model B ReciprocatingC= Scroll (42K)S= Single Cylinder SeriesT= Two Cylinder SeriesCapacity:193= 19 +(3) 0's or 19,000 BTU/Hr ; 244= 24 + (4) 0's or 240,000 BTU/Hr19Q= 19 +(3) 0's in "Quite Version" = 19,000 BTU/Hr. "Quiet"19U= 19 +(3) 0's in "Upgrade" = 19,000 BTU/Hr. "Upgrade"19B = 19 + (3) 0's Internal Bleed applied for equalized startGenerationB= Second Generation- No PRV (Except G Series)D= Dual Compressor Application (Single & Interconnected)E= High EfficiencyM= Alternate Pressure Relief ValveN= No Pressure Relief Valve (Except G Series)O= Basic Standard ModelP= Basic Standard Model - Upgrade Plus1= Second Generation - Basic Standard Model2= Third Generation - Basic Standard Model3= Fourth Generation - Basic Standard Model4= Basic Standard Model - Improved Sound5= Inertia Series - Standard Model6= Inertia Series - High Efficiency Model7= Inertia Series= Second Generation High Efficiency Model8= Fifth Generation- Basic Standard Model Upgrade9= Sixth Generation- Basic Standard Model UpgradeType of Refrigerant1= R122= R223=R134a5= R502 or Alt. Replacement Refrigerant SUVA-HP-81 (Refrigerant R402B)6= R404a (SUVA HP62)7= R407C (SUVA AC9000 or KLEA 66)8= R410ARefrigeration ApplicationH= High TemperatureM= Medium TemperatureL= Low TemperatureS= High Temperature (One Capacity / 1, 2, 3, or 4 cylinder) Half/SingleT = High Temperature (Two Capacities / 2 or 4 cylinder) - Twin/SingleB-14Mounting Feet Dim;A= 7.5 x 7.5B= 4.8 x 8.0C= 8.4 x 9.8D= 6.12 x 8.0E= 9.5 x 9.5F=10.5 x 10.5H= 7.5 x 21.5J= 7.5 x 22.5X= 8.8 x 6.1Electrical CharacteristicsA= 115-1-60B= 230-1-60C= 230/208-1-60D= 230/208-3-60 (220/200-3-50)E= 460-3-60 (380/415-3-50)F= 575-3-60 (500-3-50)G= 200-1-60H= 265-1-60 (220/240-1-50)J= 230/208-1-50K=220/240-1-50L=230/200-3-60 (220/200-3-50)M= 220/200-3-50N= 380/415-3-50P= 240/200-1-50T= 208-1-60U= 220/380-3-60V= 460/380-3-60 (380/415-3-50)W= 380/460-3-60X= 380-3-60Y= 230/208-3-60 (No 50 Hz)Motor ProtectorB= Internal Line BreakP= Pilot Duty - Solid StateR= Pilot Duty - Solid State (2nd Generation)T= Pilot Duty - Internal Thermostat and Ex ternal Sensing ElementsMotor Type:A= PSC Permanent Slip CapacitorB= CSR Capacitor Start/Cap. RunC= RSCR Resistance Start/Cap. RunD= AI 3 Phase-Across the LineE= CSIR Cap. Start/Induction RunF= PWS 3 Phase-Part Winding StartG= 3 Phase 2/4/Pole (2 Speed)J= 1 Phase 2/4 Pole (2 Speed)K= 3 Phase Dual VoltageL= 3 Phase - WYE DELTAMotorsElectricalHeatingComponentsIndoor AirQualityThermostatsOils &ChemicalsAccessories, Supplies& CommoditiesTools &InstrumentsRefrigeration
- Page 3 and 4: Compressors, Chillers & Condensers
- Page 5 and 6: Compressors, Chillers & Condensers
- Page 7 and 8: Compressors, Chillers & CondensersI
- Page 9 and 10: Compressors, Chillers & CondensersT
- Page 11 and 12: Compressors, Chillers & CondensersD
- Page 13 and 14: Compressors, Chillers & CondensersD
- Page 15 and 16: Compressors, Chillers & CondensersD
- Page 17: Compressors, Chillers & CondensersM
- Page 21: Compressors, Chillers & CondensersH
- Page 24 and 25: Compressors, Chillers & CondensersC
- Page 26: Compressors, Chillers & CondensersH
- Page 29 and 30: Compressors, Chillers & CondensersH
- Page 31 and 32: Compressors, Chillers & CondensersP
- Page 33 and 34: Compressors, Chillers & CondensersH
- Page 35 and 36: Compressors, Chillers & CondensersH
- Page 37 and 38: Compressors, Chillers & CondensersH
- Page 39 and 40: Compressors, Chillers & CondensersH
- Page 41 and 42: Compressors, Chillers & CondensersH
- Page 43 and 44: Compressors, Chillers & CondensersH
- Page 45 and 46: Compressors, Chillers & CondensersH
- Page 47 and 48: Compressors, Chillers & CondensersT
- Page 49 and 50: Compressors, Chillers & CondensersH
- Page 51 and 52: Compressors, Chillers & CondensersH
- Page 53 and 54: Compressors, Chillers & CondensersR
- Page 55 and 56: Compressors, Chillers & CondensersR
- Page 57 and 58: Compressors, Chillers & CondensersH
- Page 59 and 60: RCompressors, Chillers & Condensers
- Page 61 and 62: Compressors, Chillers & CondensersP
- Page 63 and 64: Compressors, Chillers & CondensersP
- Page 65 and 66: Compressors, Chillers & CondensersP
- Page 67 and 68: Compressors, Chillers & CondensersC
Compressors, Chillers & CondensersCompressors,Chillers, CondensersNON-CARLYLE HERMETIC <strong>COMPRESSOR</strong>SGUIDE TO PART NUMBERING SYSTEM:MotorsExample:P 040 - 1 8 5 7 1ElectricalPARTSCAPACITY(1000) BTUH/HR LARGE UNITSNUMERICALSEQUENCEPART CODE030 - GOLDSTAR031 - TECUMSEH032 - BRISTOL033 - DAEWOO034 - MATSUSHITA/PANASONIC035 - TOSHIBA036 - SANYO037 - MITSUBISHI038 - HITACHI039 - DELCHI040 - MANEUROP050 - COPELAND 50HZ051 - TECUMSEH 50HZVOLTS0 - 115/11 - 200/12*- 208-230/1-60 or220/240-1-503 - 230/14 - 200/35* 208-230/3-60 or220/240-3-506 - 230/37 - 460/38 - 575/39 - MISC265/1277/1* Different Prefix used for 50 HzSee Part Code Column.Tools &InstrumentsHeatingComponentsThermostatsOils &ChemicalsAccessories, Supplies& CommoditiesRefrigerationIndoor AirQualityB-13