13.07.2015 Views

MTR Column LED [MTRCL] selux.us

MTR Column LED [MTRCL] selux.us

MTR Column LED [MTRCL] selux.us

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Date:C<strong>us</strong>tomer:Project:Type:Qty:<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>Order Code:- - - - -- - -Series<strong>MTR</strong>TLTapered Pole<strong>MTR</strong>CLRound 8”Straight PoleNominalOverall Ht.<strong>MTR</strong>TL1212’<strong>MTR</strong>CL 10 1210’1414’12’1616’1414’1616’Nominal Ht.of Lit Section22’33’44’Light Engine 1L35 2L35 3L354L35See p. 9 for detailsCCT 27 30 352700K 3000K 3500K404000KFor other CCT please consult factoryFinishWHWhiteBKBlackBZBronzeSVSilverSPSpecify Premium ColorVoltage 120 208 240 277 347 1 480 11Requires step down transformerOptions DM HL50 2 REC 3Dimming Hi-Lo GFCI(0-10V) Switching Receptacle2120V, 240V, and277V only3120V onlyProduct ModificationsPlease list modification requirements for review by factory:Approvals5YEAR<strong>LED</strong> WARRANTYDate:Selux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 1 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong><strong>MTR</strong>TLØ8”(200mm)12634See page427Specifications1. Luminaire Cover - Die-cast aluminum cover,with smooth crisp form to reflect and complementthe column design. Removes by looseningthree stainless steel set screws for easy access tolamp chamber.2. Gasketing - Continuo<strong>us</strong> gaskets provideweather-proofing, d<strong>us</strong>t, and insect control atbase of column, fixture cover, and between <strong>MTR</strong>rings.3. Shielding - Consists of 8” (200mm) diameterinjection-molded acrylic multi-prisms for totalreflection (<strong>MTR</strong>). <strong>MTR</strong> rings have a wall thicknessof .591” and are designed after the lightbendingcharacteristics of a prism.4. <strong>LED</strong> Light Engine - High efficiency <strong>LED</strong> lightengine equipped with brand-name <strong>LED</strong>s, availablein 2700K, 3000K, 3500K, or 4000K CCT /Tolerance within a 3-step MacAdams ellipse.5. Drivers - (not shown) Electronic universal120-277V, PFC > 0.956. Diff<strong>us</strong>er - <strong>LED</strong> optimized UV resistant materialensures evenly lit <strong>MTR</strong> rings at high transmittance.7. Pole Fitter - Self-leveling, die-cast aluminum,fitter base secured to pole with two stainlesssteel Allen head set screws. 3 1/2” (89mm) O.D.poles.8. <strong>Column</strong> Fitter - (not shown) Die-cast aluminumfitter, with built-in gasketing ridges, forsmooth transition to column.9. Surge Protector - (not shown) Designed toprotect luminaire from electrical surge (10kA).10 . Base Cover - (not shown -<strong>MTR</strong>TL only) Standardtwo-piece base cover is made from diecast356 alloy aluminum, which is heat treatedto produce a T6 temper.11. Hi-Lo Switching - (not shown) For details,please see page 6.12. Thermal Foldback - (not shown) IntegratedThermal Foldback circuit will reduce the drivecurrent if the ambient temperature exceeds themaximum rated ambient temperature. This ensuresmaximum light output in vario<strong>us</strong> operatingconditions, while assuring long-term lumenmaintenance.Exterior Luminaire Finish -Selux utilizes a high quality Polyester PowderCoating. All Selux luminaires and poles arefinished in our Tiger Drylac certified facility andundergo a five stage intensive pretreatmentprocess where product is thoroughly cleaned,phosphated and sealed. Selux powder coatedproducts provide excellent salt and humidityresistance as well as ultraviolet resistance forcolor retention. All products are tested in accordancewith test specifications for coatings fromASTM and PCI.Standard exterior colors are White (WH), Black(BK), Bronze (BZ), and Silver (SV). Selux premiumcolors (SP) are available, please specify fromyour Selux color selection guide.5 Year Limited <strong>LED</strong> Luminaire Warranty -Selux offers a 5 Year Limited Warranty to theoriginal purchaser that the <strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>luminaire shall be free from defects in materialand workmanship for up to five (5) years fromdate of shipment. This limited warranty coversthe <strong>LED</strong> driver and <strong>LED</strong> array when installed andoperated according to Selux instructions. Fordetails, see “Selux Terms and Condition of Sale.”Listings and Ratings: Tested to NRTL WetLocation and IESNA LM-79-08 standards.<strong>LED</strong> tested to LM-80 standards. Luminaire and<strong>LED</strong> tested at 25°C (77°F) ambient temperature.NRTL Listed (i.e. UL, CSA)Visit <strong>selux</strong>.<strong>us</strong> for our <strong>LED</strong> End of Liferecycling policy.Ambient TemperatureChart (standard)Minimum Maximum-35° C(-31° F)45° C(113° F)Selux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 2 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>Mounting - <strong>MTR</strong>CL*Minimum clearance required(for maintenance or future upgrades)4’ head = 60” (1524mm)3’ head = 48” (1219mm)2’ head = 36” (914mm)*consult factory for alternative recommendationsif access above fixture is not available3’ - 8 3/16”(1123mm)4’ Lit SectionØ8”(200mm)Typical allHeights2’ - 9 7/8”(861mm)3’ Lit Section1’ - 11 1/16”(585mm)2’ Lit SectionHeight (12’ Nominal Shown) = See Chart Below for All HeightsPole Height is Nominal3 1/2” (89mm)Typical all HeightsØ8”(200mm)Typical allHeightsHeight (12’ Nominal Shown) = See Chart Below for All HeightsPole Height is NominalHeight (12’ Nominal Shown) = See Chart Below for All HeightsPole Height is Nominal3 1/2” (89mm)Typical all Heights4” x 7” (102mm x 178mm)Handhole provided with fl<strong>us</strong>hcover and stainless steeltamper-resistant hardware.Typical All HeightsOverall Height Nominal(Actual)Lit Section Nominal(Actual)Pole Height Nominal(Actual)Total <strong>Column</strong>Weight (lb)ASSHTO 1994Max EPA Wind RatingASSHTO 2001Max EPA Wind RatingASSHTO 2009Max EPA Wind Rating10’ (9’ - 10 1/16”) 4’ (3’ - 8 3/16”) 6’ (6’ - 1 13/16”) 62 (28 kg) 200mph 200mph 200mph10’ (9’ - 10 1/4”) 3’ (2’ - 9 7/8”) 7’ (7’ - 0 5/16”) 53 (24 kg) 200mph 200mph 200mph10’ (10’ - 0 7/8”) 2’ (1’ - 11 1/16”) 8’ (8’ - 1 13/16”) 51 (23 kg) 200mph 200mph 200mph12’ (11’ - 10 1/16”) 4’ (3’ - 8 3/16”) 8’ (8’ - 1 13/16”) 69 (31 kg) 200mph 200mph 200mph12’ (11’ - 10 1/4”) 3’ (2’ - 9 7/8”) 9’ (9’ - 0 5/16”) 60 (27 kg) 200mph 200mph 200mph12’ (12’ - 0 7/8”) 2’ (1’ - 11 1/16”) 10’ (10’ - 1 13/16”) 58 (26 kg) 200mph 200mph 200mph14’ (13’ - 10 1/16”) 4’ (3’ - 8 3/16”) 10’ (10’ - 1 13/16”) 76 (34 kg) 200mph 200mph 200mph14’ (13’ - 10 1/4”) 3’ (2’ - 9 7/8”) 11’ (11’ - 0 5/16”) 66 (30 kg) 200mph 200mph 200mph14’ (14’ - 0 7/8”) 2’ (1’ - 11 1/16”) 12’ (12’ - 1 13/16”) 64 (29 kg) 200mph 200mph 200mph16’ (15’ - 10 1/16”) 4’ (3’ - 8 3/16”) 12’ (12’ - 1 13/16”) 82 (37 kg) 200mph 200mph 200mph16’ (15’ - 10 1/4”) 3’ (2’ - 9 7/8”) 13’ (13’ - 0 5/16”) 73 (33 kg) 200mph 200mph 200mph16’ (15’ - 9 13/16”) 2’ (1’ - 11 1/16”) 14’ (13’ - 10 13/16”) 70 (32 kg) 200mph 200mph 200mphSelux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 3 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>Mounting - <strong>MTR</strong>TL*Minimum clearance required(for maintenance or future upgrades)4’ head = 60” (1524mm)3’ head = 48” (1219mm)2’ head = 36” (914mm)3’ - 9 1/4”(1149mm)4’ Lit SectionØ8”(200mm)Typical allHeights*consult factory for alternative recommendationsif access above fixture is not available2’ - 10 15/16”(887mm)3’ Lit Section2’(610mm)2’ Lit SectionHeight (12’ Nominal Shown) = See Chart Below for All HeightsPole Height is Nominal1’ - 3 1/2” (394mm)Typical all HeightsØ7”(178mm)Typical allHeightsHeight (12’ Nominal Shown) = See Chart Below for All HeightsPole Height is NominalHeight (12’ Nominal Shown) = See Chart Below for All HeightsPole Height is Nominal3” x 5” (76mm x 127mm)Handhole provided with fl<strong>us</strong>hcover and stainless steeltamper-resistant hardware.Typical All HeightsØ5”(127mm)Typical allHeightsSingle 4’ Lit Section (Fixture Head)Effective Projected Area = 1.3 ft 2 (0.120m 2 )Weight of Luminaire = 38 lb. (17kg)Single 3’ Lit Section (Fixture Head)Effective Projected Area = 1 ft 2 (0.092m 2 )Weight of Luminaire = 26 lb. (12kg)Single 2’ Lit Section (Fixture Head)Effective Projected Area = 0.7 ft 2 (0.065m 2 )Weight of Luminaire = 20 lb. (9kg)Overall Height Nominal(Actual)Lit Section Nominal(Actual)Pole Height Nominal(Actual)Total <strong>Column</strong>Weight (lb)ASSHTO 1994Max EPA Wind RatingASSHTO 2001Max EPA Wind RatingASSHTO 2009Max EPA Wind Rating12’ (11’ - 9 9/16”) 4’ (3’ - 9 1/4”) 8’ (7’ - 9 1/16”) 63 (29 kg) 110mph 150mph 150mph12’ (11’ - 9 3/4”) 3’ (2’ - 10 15/16”) 9’ (8’ - 7 9/16”) 51 (23 kg) 110mph 150mph 150mph12’ (12’ - 0 5/16”) 2’ (2’) 10’ (9’ - 9 1/16”) 50 (23 kg) 110mph 150mph 150mph14’ (13’ - 9 9/16”) 4’ (3’ - 9 1/4”) 10’ (9’ - 9 1/16”) 68 (31 kg) 110mph 150mph 150mph14’ (13’ - 9 3/4”) 3’ (2’ - 10 15/16”) 11’ (10’ - 7 9/16”) 56 (25 kg) 110mph 150mph 150mph14’ (14’ - 0 5/16”) 2’ (2’) 12’ (11’ - 9 1/16”) 55 (25 kg) 110mph 150mph 150mph16’ (15’ - 9 9/16”) 4’ (3’ - 9 1/4”) 12’ (11’ - 9 1/16”) 78 (35 kg) 110mph 150mph 150mph16’ (15’ - 9 3/4”) 3’ (2’ - 10 15/16”) 13’ (12’ - 7 9/16”) 66 (30 kg) 110mph 150mph 150mph16’ (15’ - 9 3/8”) 2’ (2’) 14’ (13’ - 6 1/8”) 65 (29 kg) 110mph 150mph 150mphSelux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 4 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>WiringStandard Single WiringFor 120-277VHi-Lo Switching Option (HL) WiringFor 120-277V. When red is energized, light output will be at “Lo” level. Standard HL level:HL50 = low output, 50%. For other “Lo” levels, consult factory.SurgeProtectorSurgeProtectorL1BlackL1BlackFromLineCordNWhiteGreenLightEngineFromLineCordNWhiteGreenLightEngineGroundGroundL2Red0-10V Dimming Option (DM) WiringFor 120-277VSurgeProtectorL1BlackNWhiteFromLineCordGreenLightEngineDim (-)OrangeGroundDim (+)RedSelux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 6 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>Wiring347/ 480V (Standard)347/480V with 0-10V Dimming OptionSurgeProtectorAutoTransformerSurgeProtectorAutoTransformerL1BlackL1BlackFromLineCordNWhiteGreenLightEngineFromLineCordNWhiteGreenLightEngineGroundDim (-)OrangeGroundDim (+)RedSelux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 7 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>Optional AccessoriesGFCI Receptacle (REC)GFCI duplex receptacle with cast base bolted to pole and gasketed, provided withweather-proof, self-closing cover; located 36” (915mm) from base of pole, inlinewith handhole. Receptacle is intended only for portable tools or other portableequipment to be connected to outlet only when attended by operating personnel.2 13/16”(71mm)13/16”(21mm)4 5/8”(117mm)Selux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 8 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8


<strong>MTR</strong> <strong>Column</strong> <strong>LED</strong>Energy Consumption*4000K CCT<strong>LED</strong> Information1L35 2L35 3L35 4L35Lit Section Height 2’ 3’ 4’ 2’ 3’ 4’ 2’ 3’ 4’ 2’ 3’ 4’Delivered Lumens (lm) 1187 1781 2374 2275 3413 4551 3364 5064 6728 4452 6678 8904Wattage (W) 17 25 34 32 48 64 46 69 93 60 90 120Efficacy (lm/W) 71 71 71 71 71 71 73 73 73 74 74 74Conversion Chart(Values based on 4000K)CCT2700K3000K3500K4000KMultiply0.940.950.981.00*data based on 350mA <strong>LED</strong> driver current.Photometry<strong>MTR</strong>TL / 1L35 / 4000K CCT6083Catalog #: <strong>MTR</strong>TL-12-4-1L35-40-120Delivered Lumens: 2374Input Watts: 34WEfficacy: 71 lm/WCRI: 84Maximum candela of 608 at 62.5° from vertical.IES classification: Type IVMounting Height = 12’ (3.66 m)B0-U4-G2Power Factor: 1.0Total Harmonic Distortion: 8.69%4563041521210123.1.2.51Ho<strong>us</strong>eSideStreetSideLink to photometry (PDF)Link to photometry (IES)450 123456 7<strong>MTR</strong>TL / 4L35 / 4000K CCT9823.2.1Catalog #: <strong>MTR</strong>TL-12-4-4L35-40-120Delivered Lumens: 8904Input Watts: 120WEfficacy: 74 lm/WCRI: 84Maximum candela of 982 at 57° from vertical.IES classification: Type VMounting Height = 12’ (3.66 m)B2-U5-G3Power Factor: 1.0Total Harmonic Distortion: 8.69%7374912461210123.512Ho<strong>us</strong>eSideStreetSideLink to photometry (PDF)Link to photometry (IES)450 123456 7<strong>LED</strong> Light Engine Distribution Guide1L35 2L35 3L35 4L35Handhole Side - For <strong>MTR</strong>TL,fixture head orientation in relationto Handhole is field adj<strong>us</strong>table.<strong>MTR</strong>CL is NOT field adj<strong>us</strong>table.Selux Corporation © 2014, T 845-834-1400, 800-735-8927, F 845-834-1401, www.<strong>selux</strong>.<strong>us</strong>In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will notalter the function of the product. Specification sheets found at www.<strong>selux</strong>.<strong>us</strong> are the most recent versions and supercede all other printed or electronic versions.Page 9 of 9(Rev. 06/2014)<strong>MTR</strong>CL_ss_v1.8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!