13.07.2015 Views

GAIL (India) Limited

GAIL (India) Limited

GAIL (India) Limited

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

47.0 CONEENSATE & DRAIN PIPING:7.1 All pipes to be used for condensate drain shall be approved make and fittings as per BIS4736 or galvanized steel class B (medium class) conforming to relevant BIS codes.7.2 All jointing in the pipe system shall be by screwed fittings using non-hardening lubricant assealing material and/or by screwed flanges using 3mm 3 ply rubber gaskets. Pipe threadsand flanges shall be as per BS 534 and BS 45047.3 All pipe supports shall be mild steel, thoroughly cleaned and given on primary coat of redoxide paint before being installed.7.4 Fittings shall be galvanized steel 'Medium Class' malleable casting of pressure ratingsuitable for the piping system. Flanges shall be of approved make. Supply of flanges shallinclude bolts, washers, gaskets as required sufficient number of flanges and unions shall beprovided for future cleaning and servicing of piping. Tee-off connections shall bethrough equal or reducing tees. All equipment and valve connections, or connections toany other mating pipe shall be through unions/screwed flanges upto 50 mm dia andthrough screwed flanges for larger diameters, or as required for the mating connections.7.5 All condensate drain piping shall be insulated as per the section 'Insulation' Cold waterpiping within the building may also be insulated.7.6 After the piping has been installed, tested and run for atleast three days of eight hourseach, all piping and pipe supports shall be painted with one coat of red oxide paint & twofinish coats of 3 mils each of approved color of synthetic enamel paint conforming to IS23797.7 The direction of flow of fluid in the pipes shall be visibly marked with identifying arrow.8.0 REFRIGERANT PIPING:a. All refrigerant pipes and fittings shall be type L' hard drawn copper tubes and wroughtcopper fitting suitable for connection with silver solder phos copper or as perManufacturers recommendations.b. All joints in copper piping shall be sweat joints using low temperature brazing and/orsilver solder. Before jointing any copper pipe or fittings, its interior shall be thoroughlycleaned be passing a clean cloth via wire or cable through its entire length. The piping shallbe continuously kept clean of dirt etc. while construction the joints. Subsequently, it shallbe thoroughly blown out using carbon-dioxide/nitrogen.c. Refrigerant lines shall be sized to limit pressure drop between evaporator andcondensing unit to less than 0.2 kg per Sq.cm.d. Removable type combination drier and filter shall be installed in liquid line of therefrigeration system incorporating a three way valve bypass. After ninety days ofoperation, liquid line drier and filter cartridges must be replaced by contractor atactual cost to be borne by owner.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!