<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong> Section 6<br />
EntelliGuard ® G <strong>Circuit</strong> Breaker<br />
EntelliGuard ® G <strong>Circuit</strong> Breaker Nomenclature<br />
Digit 11 Second Shunt Trip, Second UVR<br />
Type Code<br />
24Vdc 1<br />
30Vdc 2<br />
48Vac/dc 3<br />
Second UVR with Fixed 60-72Vdc 4<br />
Time Delay1 110Vdc/130Vdc; 120Vac 5<br />
208Vac 6<br />
220Vdc; 240Vac 7<br />
250Vdc; 277Vac 8<br />
24Vdc M<br />
48Vac/dc P<br />
Second Extended 70-72Vdc Q<br />
Range Shunt Trip 110/125Vdc; 120Vac R<br />
(ANSI/UL) 2 208Vac S<br />
220Vdc; 240Vac T<br />
250Vdc; 277Vac V<br />
Blank/none X<br />
1The UVR with Fixed Time Delay is specifically intended for applications where a delay period ('ride- through') is required due to potential voltage events. The design delays<br />
are 50msec when system voltage drops to 50% <strong>and</strong> 20msec when system voltage drops below 50%.<br />
2The Extended Range Shunt Trip is specifically intended <strong>and</strong> required for UL ANSI Ground Fault applications. The pick up range is 55-110% of the ST coil voltage.<br />
An optional External UVR Time Delay Module is available in a 1 - 3 second delay.<br />
SELECT ONE DEVICE ONLY.<br />
Digit 12 Auxiliary Switch, Coil Signaling Contact<br />
Contact Configuration Code<br />
Auxiliary Switch, 3NO+3NC (<strong>Power</strong> Rated) 3 STANDARD/INCLUDED 2<br />
Auxiliary Switch, 8NO+8NC (<strong>Power</strong> Rated) 4 4<br />
Aux. Switch, 3NO/3NC (<strong>Power</strong> Rated) +2NO/2NC (High Fidelity) 6<br />
Aux. Switch, 4NO/4NC (<strong>Power</strong> Rated) +4NO/4NC (High Fidelity) 4 8<br />
CSC, PR, (1NO on SD) - Close Coil or CCC A<br />
CSC, Hi-Fi via Trip Unit - Close Coil or CCC5 B<br />
CSC, PR, (1NO on SD) - 1st Shunt Trip C<br />
Auxiliary Switch, 3NO+3NC CSC,Hi-Fi via Trip Unit - 1st Shunt Trip 5 D<br />
(<strong>Power</strong> Rated) CSC, PR, (1 NO on SD) - 1st UVR E<br />
CSC,Hi-Fi via Trip Unit - 1st UVR5 F<br />
CSC, PR, (1NO on SD) - 2nd ST or 2nd UVR G<br />
CSC, Hi-FI via Trip Unit - 2nd ST or 2nd UVR5 H<br />
CSC, PR, (1NO on SD) - Close Coil or CCC J<br />
CSC, Hi-Fi via Trip Unit - Close Coil or CCC5 K<br />
CSC, PR, (1NO on SD) - 1st Shunt Trip L<br />
Auxiliary Switch, 3NO/3NC (<strong>Power</strong> Rated)+2NO/2NC (High Fidelity)<br />
CSC,Hi-Fi via Trip Unit - 1st Shunt Trip5 CSC, PR, (1 NO on SD) - 1st UVR<br />
M<br />
N<br />
CSC,Hi-Fi via Trip Unit - 1st UVR5 P<br />
CSC, PR, (1NO on SD) - 2nd ST or 2nd UVR Q<br />
CSC, Hi-FI via Trip Unit - 2nd ST or 2nd UVR5 R<br />
Auxiliary Switch, 3NO+3NC (<strong>Power</strong> Rated)<br />
CSC, PR, (1NO on SD) - All Installed Devices<br />
CSC,HI-Fi via Trip Unit - All Installed Devices<br />
S<br />
5 T<br />
Aux. Switch, 3NO/3NC (<strong>Power</strong> Rated) + 2NO/2N (High Fidelity)<br />
CSC, PR, (1NO on SD) - All Installed Devices<br />
CSC,HI-Fi via Trip Unit - All Installed Devices<br />
U<br />
5 V<br />
Abbreviations<br />
CCC = Comm<strong>and</strong> Operated Close Coil<br />
CSC = Coil Signaling Contact<br />
Hi-Fi = High Fidelity<br />
PR = <strong>Power</strong> Rated<br />
SD = Secondary Disconnect<br />
NOTE: The term "Hi Fidelity" (HiFi) refers to gold-plated contacts used for signal level outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac)<br />
NOTE: If no devices were selected in Digit 8, 9, 10, 11 (Codes = "X"), then Options A - V are Invalid<br />
NOTE: Options A-V are only valid if the corresponding device to be monitored by the Coil Signaling Contact (CSC) is selected in digits 8, 9, 10, 11<br />
3 The 3NO/3NC scheme is STANDARD (INCLUDED, CODE 2) <strong>and</strong> is wired to Secondary Disconnect Block A; all other selections require Secondary Disconnect Block B<br />
4 For Side-mounted Secondary Disconnect Blocks All options are available EXCEPT options (4 <strong>and</strong> 8)<br />
5 In order to output the Coil Signaling status HiFi via trip unit (Options B, D, F, H, K, M, P, R, T, <strong>and</strong> V) a communications package must be selected in Advanced Features (Digit<br />
19; options "2, 3, 6, 7, 8, 9") This options requires Secondary Disconnect Block B.<br />
If a UL or ANSI Switch is selected in Digit 2 (C, D, M, S), the HiFi via Trip unit Options are not valid (Options B, D, F, H, K, M, P, R, T, <strong>and</strong> V)<br />
Note: See EntelliGuard ® G <strong>Circuit</strong> Breaker Configurator for pricing. Contact a sales representative for configurator.<br />