<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong> Section 6<br />

EntelliGuard ® G <strong>Circuit</strong> Breaker<br />

EntelliGuard ® G <strong>Circuit</strong> Breaker Nomenclature<br />

Digit 11 Second Shunt Trip, Second UVR<br />

Type Code<br />

24Vdc 1<br />

30Vdc 2<br />

48Vac/dc 3<br />

Second UVR with Fixed 60-72Vdc 4<br />

Time Delay1 110Vdc/130Vdc; 120Vac 5<br />

208Vac 6<br />

220Vdc; 240Vac 7<br />

250Vdc; 277Vac 8<br />

24Vdc M<br />

48Vac/dc P<br />

Second Extended 70-72Vdc Q<br />

Range Shunt Trip 110/125Vdc; 120Vac R<br />

(ANSI/UL) 2 208Vac S<br />

220Vdc; 240Vac T<br />

250Vdc; 277Vac V<br />

Blank/none X<br />

1The UVR with Fixed Time Delay is specifically intended for applications where a delay period ('ride- through') is required due to potential voltage events. The design delays<br />

are 50msec when system voltage drops to 50% <strong>and</strong> 20msec when system voltage drops below 50%.<br />

2The Extended Range Shunt Trip is specifically intended <strong>and</strong> required for UL ANSI Ground Fault applications. The pick up range is 55-110% of the ST coil voltage.<br />

An optional External UVR Time Delay Module is available in a 1 - 3 second delay.<br />

SELECT ONE DEVICE ONLY.<br />

Digit 12 Auxiliary Switch, Coil Signaling Contact<br />

Contact Configuration Code<br />

Auxiliary Switch, 3NO+3NC (<strong>Power</strong> Rated) 3 STANDARD/INCLUDED 2<br />

Auxiliary Switch, 8NO+8NC (<strong>Power</strong> Rated) 4 4<br />

Aux. Switch, 3NO/3NC (<strong>Power</strong> Rated) +2NO/2NC (High Fidelity) 6<br />

Aux. Switch, 4NO/4NC (<strong>Power</strong> Rated) +4NO/4NC (High Fidelity) 4 8<br />

CSC, PR, (1NO on SD) - Close Coil or CCC A<br />

CSC, Hi-Fi via Trip Unit - Close Coil or CCC5 B<br />

CSC, PR, (1NO on SD) - 1st Shunt Trip C<br />

Auxiliary Switch, 3NO+3NC CSC,Hi-Fi via Trip Unit - 1st Shunt Trip 5 D<br />

(<strong>Power</strong> Rated) CSC, PR, (1 NO on SD) - 1st UVR E<br />

CSC,Hi-Fi via Trip Unit - 1st UVR5 F<br />

CSC, PR, (1NO on SD) - 2nd ST or 2nd UVR G<br />

CSC, Hi-FI via Trip Unit - 2nd ST or 2nd UVR5 H<br />

CSC, PR, (1NO on SD) - Close Coil or CCC J<br />

CSC, Hi-Fi via Trip Unit - Close Coil or CCC5 K<br />

CSC, PR, (1NO on SD) - 1st Shunt Trip L<br />

Auxiliary Switch, 3NO/3NC (<strong>Power</strong> Rated)+2NO/2NC (High Fidelity)<br />

CSC,Hi-Fi via Trip Unit - 1st Shunt Trip5 CSC, PR, (1 NO on SD) - 1st UVR<br />

M<br />

N<br />

CSC,Hi-Fi via Trip Unit - 1st UVR5 P<br />

CSC, PR, (1NO on SD) - 2nd ST or 2nd UVR Q<br />

CSC, Hi-FI via Trip Unit - 2nd ST or 2nd UVR5 R<br />

Auxiliary Switch, 3NO+3NC (<strong>Power</strong> Rated)<br />

CSC, PR, (1NO on SD) - All Installed Devices<br />

CSC,HI-Fi via Trip Unit - All Installed Devices<br />

S<br />

5 T<br />

Aux. Switch, 3NO/3NC (<strong>Power</strong> Rated) + 2NO/2N (High Fidelity)<br />

CSC, PR, (1NO on SD) - All Installed Devices<br />

CSC,HI-Fi via Trip Unit - All Installed Devices<br />

U<br />

5 V<br />

Abbreviations<br />

CCC = Comm<strong>and</strong> Operated Close Coil<br />

CSC = Coil Signaling Contact<br />

Hi-Fi = High Fidelity<br />

PR = <strong>Power</strong> Rated<br />

SD = Secondary Disconnect<br />

NOTE: The term "Hi Fidelity" (HiFi) refers to gold-plated contacts used for signal level outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac)<br />

NOTE: If no devices were selected in Digit 8, 9, 10, 11 (Codes = "X"), then Options A - V are Invalid<br />

NOTE: Options A-V are only valid if the corresponding device to be monitored by the Coil Signaling Contact (CSC) is selected in digits 8, 9, 10, 11<br />

3 The 3NO/3NC scheme is STANDARD (INCLUDED, CODE 2) <strong>and</strong> is wired to Secondary Disconnect Block A; all other selections require Secondary Disconnect Block B<br />

4 For Side-mounted Secondary Disconnect Blocks All options are available EXCEPT options (4 <strong>and</strong> 8)<br />

5 In order to output the Coil Signaling status HiFi via trip unit (Options B, D, F, H, K, M, P, R, T, <strong>and</strong> V) a communications package must be selected in Advanced Features (Digit<br />

19; options "2, 3, 6, 7, 8, 9") This options requires Secondary Disconnect Block B.<br />

If a UL or ANSI Switch is selected in Digit 2 (C, D, M, S), the HiFi via Trip unit Options are not valid (Options B, D, F, H, K, M, P, R, T, <strong>and</strong> V)<br />

Note: See EntelliGuard ® G <strong>Circuit</strong> Breaker Configurator for pricing. Contact a sales representative for configurator.<br />

6-8<br />

BuyLog ® Catalog<br />

www.geindustrial.com<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice