<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />

Trip Units<br />

Product Number Nomenclature System<br />

MicroVersaTrip ® Plus, MicroVersaTrip ® PM Trip Unit <strong>and</strong> WavePro Product Number<br />

Breaker Type<br />

A = AKR<br />

Breaker Frame<br />

3 = 3200A<br />

Installed CT<br />

04 = 400A<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice<br />

A<br />

Overcurrent Protection<br />

LSI = Long Time, Short Time, Instantaneous<br />

MVT PLUS/PM - WavePro<br />

Step 1 Breaker Type<br />

3<br />

32 LSI G Z1 PM R<br />

Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8<br />

Breaker Type Code<br />

WavePro K<br />

Step 2 Breaker Frame<br />

Frame Size Code<br />

800A 8<br />

1600A 1<br />

2000A 2<br />

3200A 3<br />

4000A 4<br />

5000A 5<br />

Step 3 Installed CT<br />

Installed CT Code<br />

150A 01<br />

400A 04<br />

600A 06<br />

800A 08<br />

1600A 16<br />

2000A 20<br />

3200A 32<br />

4000A 40<br />

5000A 50<br />

Step 4 Overcurrent Protection<br />

Overcurrent Protection Code<br />

Long-Time ( St<strong>and</strong>ard) L<br />

Short-Time S<br />

Instantaneous I<br />

Section 6<br />

Remanufactured<br />

RM = Remanufactured Trip Unit<br />

RX = Exchanged Trip Unit<br />

Optional Features<br />

PM = Relaying, Metering, Communication<br />

Optional Protection<br />

Z1 = Ground Fault Zone - Selective Interlock<br />

Ground Fault Protection<br />

G = Ground Fault<br />

Step 5 Ground Fault Protection<br />

Ground Fault Protection Code<br />

Ground Fault G<br />

Defeatable ground fault (user defeatbale) GD<br />

Step 6 Replacement<br />

Optional Protection Code<br />

Ground-Fault zone -selective interlock Z1<br />

Ground-Fault <strong>and</strong> short-time ZSI Z2<br />

Switchable instantaneous, short time <strong>and</strong> ground fault X<br />

Step 7 Optional Features<br />

Optional Features Code<br />

Protective Relays <strong>and</strong> Communication P<br />

Metering <strong>and</strong> Communication M<br />

Step 8 Remanufactured<br />

Remanufactured Code<br />

Remanufactured trip unit RM<br />

Exchanged trip unit RX<br />