<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong> Section 6<br />

Trip Units<br />

Product Number Nomenclature System<br />

<strong>Power</strong>+ Trip Unit <strong>and</strong> <strong>Power</strong> Break II Product Numbers<br />

Trip Unit Type <strong>and</strong> Rating<br />

D2 = <strong>Power</strong> Break ® II <strong>Power</strong>+ Trip Unit:<br />

2000 A sensor maximum<br />

D3 = <strong>Power</strong> Break ® II <strong>Power</strong>+ Trip Unit:<br />

3000 A sensor maximum<br />

D4 = <strong>Power</strong> Break ® II <strong>Power</strong>+ Trip Unit:<br />

4000 A sensor maximum<br />

Current Sensor Rating<br />

02 = 200 A 20 = 2000 A<br />

04 = 400 A 25 = 2500 A<br />

08 = 800 A 30 = 3000 A<br />

10 = 1000 A 40 = 4000 A<br />

16 = 1600 A<br />

D2<br />

20<br />

T1 R 1<br />

1 Device Product Number requires an extender “R” for field installable kit version only.<br />

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.<br />

<strong>Power</strong>+ Rating Plug Product Numbers<br />

TR<br />

Trip Unit Type Rating<br />

TR = Trip unit rating plug<br />

All <strong>Power</strong>+, MicroVersaTrip ® Plus,<br />

<strong>and</strong> MicroVersaTrip ® PM<br />

rating plugs<br />

Current Sensor Rating<br />

02 = 200 A 20 = 2000 A<br />

04 = 400 A 25 = 2500 A<br />

08 = 800 A 30 = 3000 A<br />

10 = 1000 A 40 = 4000 A<br />

16 = 1600 A<br />

Trip Unit Type<br />

C = <strong>Power</strong>+ trip unit rating plugs<br />

10<br />

C<br />

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.<br />

6-60<br />

<strong>Power</strong>+ Target Module Product Numbers<br />

TAR<strong>GE</strong>T00 = Blank insert for Target Module<br />

TAR<strong>GE</strong>T01 = Target Module without ground fault target<br />

TAR<strong>GE</strong>T02 = Target Module with ground fault target<br />

BuyLog ® Catalog<br />

LSI<br />

Replacement or New<br />

R = Replacement trip unit<br />

(Blank) = New<br />

Trip unit options<br />

T1 = Target Module without ground fault target<br />

T2 = Target Module with ground fault target<br />

(Blank) = Factory Installed<br />

Auxiliary functions<br />

LI = Long-time <strong>and</strong> Instantaneous<br />

LSI = Long-time, Short-time, Instantaneous<br />

800 GF<br />

Ground Fault Function<br />

Blank = No ground fault<br />

GF = Ground fault<br />

Rating Plug Ampere Rating<br />

100 = 100 A 800 = 800 A<br />

150 = 150 A 1000 = 1000 A<br />

200 = 200 A 1100 = 1100 A<br />

225 = 225 A 1200 = 1200 A<br />

250 = 250 A 1500 = 1500 A<br />

300 = 300 A 1600 = 1600 A<br />

400 = 400 A 2000 = 2000 A<br />

450 = 450 A 2500 = 2500 A<br />

500 = 500 A 3000 = 3000 A<br />

600 = 600 A 3600 = 3600 A<br />

700 = 700 A 4000 = 4000 A<br />

www.geindustrial.com<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice