<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong> Trip Units Product Number Nomenclature System Digit 6 <strong>and</strong> 7 Overcurrent Protection Package Type Over Current (OC) Protection Package Code LSI (S, switchable) (I, switchable ANSI only) L3 PB1 <strong>and</strong> PBII, AK, AKR, LSIG (S, switchable) (I, switchable ANSI only) L4 WavePro, Conv Kits LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) L5 Legacy ANSI/UL LSIGDA1 (S, G, A switchable) (I, switchable ANSI only) L8 OC Protection LSI (S, switchable) (I, Non-switchable UL891 applications) LP WavePro LSIG (S, switchable) (I, Non-switchable UL891 applications) LQ LSIGA (S, switchable) (I, Non-switchable UL891 applications) (G, Alarm Only) LR LSIGDA1 (S, G, A switchable) (I, Non-switchable UL891 applications) LS 1 Function Combination is NOT UL Listed NOTES: L = Long Time (L, I 2 T) + Fuse Settings (I 4 T) (Fuse settings are now st<strong>and</strong>ard on all EntelliGuard ® Trip Units) S = Short Time (Switchable if Instantaneous (I) protection is enabled) I = St<strong>and</strong>ard Range Adjustable Instantaneous, (IOC, 2x-15x) Digit 8 Zone Selective Interlocking (ZSI) Zone Selective Interlocking Code ZSI, Short time <strong>and</strong> Ground Fault; user selectable Z ZSI, Instantaneous, Short Time, <strong>and</strong> Ground Fault; user selectable T Blank/None X All ZSI selections require a special harness (contact factory) <strong>and</strong> 24Vdc control power. ZSI Instantaneous (T), <strong>Power</strong> Break ® can only be used as a Feeder (ZSI-I out) Digit 9 Advanced Features <strong>and</strong> Communications Advanced Features Conv <strong>and</strong> Communications Digit 9 WP PBII AKR Kits NONE (Ammeter) X x x x Ammeter, Reduced Energy Let-Through (RELT) 1 x x x x Ammeter, Modbus Protocol + RELT 2 x Monitoring + Data Acquisition, Modbus Protocol + RELT 6 x x x Monitoring + Data Acquisition + Relay Package, Modbus + RELT 8 x x x x Ammeter, Modbus Protocol (Without RELT) A x Monitoring + Data Acquisition, Modbus Protocol (without RELT) D x x x Monitoring + Data Acquisition + Relay Package, Modbus (without RELT) NOTES: E x x x x All Advanced Feature selections require 24Vdc control power RELT = Reduced Energy Let Through (Harness may be required, contact factory) Monitoring = Advanced Metering (Harness may be required, contact factory) Data Acquisition = Waveform Capture <strong>and</strong> Harmonic Analysis Options A, D, E are available when Ground Fault Alarm is selected Digit 10 Manual/Auto Trip Reset Manual/Auto Trip Reset Code Manual Reset (ANSI/UL EntelliGuard ® G Only) M Automatic Reset (ANSI/UL EntelliGuard ® G Only) A Automatic Reset (IEC EntelliGuard ® G Only) S Not Applicable (<strong>Power</strong> Break ® , <strong>Power</strong> Break ® II, WavePro, AKR, Conv Kits) X 6-58 BuyLog ® Catalog EntelliGuard ® TU Pricing www.geindustrial.com Section 6 G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing), Trip <strong>and</strong> Alarm D = Defeatable/Switchable Ground Fault, NOT UL Listed A = Ground Fault, Alarm only GA = Ground Fault Alarm Only GDA = Ground Fault Trip <strong>and</strong> Ground Fault Alarm (all switchable, Not UL Listed) Digit 11 Original/Replacement Trip Unit Original/Replacement Code Factory Installed (Original) F Replacement (Field Installed) R List Price <strong>Circuit</strong> Break Type Code 1 <strong>and</strong> 2 GO-329L All <strong>Circuit</strong> <strong>Breakers</strong> G $830.00 List Price OC Protection Package Code 6 <strong>and</strong> 7 GO-329L LSI (S, switchable) (I, switchable ANSI only) L3 $2860.00 LSIG (S, switchable) (I, switchable ANSI only) L4 $3260.00 LSIGA (S, switchable) (I, switchable ANSI only) L5 $3260.00 LSIGDA 2 (S, G, A all switchable) (I, switchable ANSI only) L8 $3520.00 JSI (S, switchable) (I, switchable ANSI only) J3 $3030.00 JSIG (S, switchable) (I, switchable ANSI only) J4 $3435.00 JSIGA (S, switchable) (I, switchable ANSI only) J5 $3435.00 JSIGDA 1 (S, G, A all switchable) (I, switchable ANSI only) J8 $3690.00 List Price Zone Selective Interlocking Code 8 GO-329L None Selected X $0.00 ZSI, Short time <strong>and</strong> GF; user selectable Z $360.00 Z + IOC or HSIOC ZSI; user selectable T $720.00 List Price Advanced Features <strong>and</strong> Communications Code 9 GO-329L None Selected X $0.00 Reduced Energy Let-Through (RELT) 1 $400.00 Modbus Protocol Only 2 $900.00 Monitoring Only 4 $1530.00 Monitoring + Relay Package 5 $1630.00 Monitoring + Data Acquisition, Modbus Protocol 6 $2040.00 Monitoring + Data Acquisition + Relay Package, Modbus 1Function Combination is NOT UL Listed 8 $2240.00 Rev. 9/12 Prices <strong>and</strong> data subject to change without notice
<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong> Trip Units Product Number Nomenclature System EntelliGuard ® TU Trip Unit Rating Plug Product Numbers Trip Unit Type Rating GTP = Trip unit rating plug EntelliGuard ® TU Trip Unit Rev. 9/12 Prices <strong>and</strong> data subject to change without notice GTP Rating Plug Ampere Rating 0060 = 60A 0080 = 80A 0100 = 100A 0125 = 125A 0150 = 150A 0200 = 200A 0225 = 225A 0250 = 250A 0300 = 300A 0350 = 350A 0400 = 400A 0450 = 450A 0500 = 500A 0600 = 600A 0700 = 700A 0750 = 750A 0800 = 800A 0900 = 900A Trip Unit Type U = Universal Trip Plug 1000 = 1000A 1100 = 1100A 1200 = 1200A 1500 = 1500A 1600 = 1600A 1700 = 1700A 1800 = 1800A 1900 = 1900A 2000 = 2000A 2200 = 2200A 2400 = 2400A 2500 = 2500A 3000 = 3000A 3200 = 3200A 3600 = 3600A 4000 = 4000A 5000 = 5000A 6000 = 6000A 1100 U 12 25 Largest Current Sensor Rating 01 = 150A 02 = 200A 03 = 225A 04 = 400A 06 = 600A 07 = 630A 08 = 800A 10 = 1000A 12 = 1200A 13 = 1250A Largest Current Sensor Rating 01 = 150A 02 = 200A 03 = 225A 04 = 400A 06 = 600A 07 = 630A 08 = 800A 10 = 1000A 12 = 1200A 13 = 1250A 16 = 1600A 20 = 2000A 25 = 2500A 30 = 3000A 32 = 3200A 40 = 4000A 50 = 5000A 60 = 6000A 64 = 6400A 16 = 1600A 20 = 2000A 25 = 2500A 30 = 3000A 32 = 3200A 40 = 4000A 50 = 5000A 60 = 6000A 64 = 6400A Section 6 www.geindustrial.com BuyLog ® Catalog 6-59