03.12.2012 Views

Low Voltage Power and DC Circuit Breakers - GE Industrial Systems

Low Voltage Power and DC Circuit Breakers - GE Industrial Systems

Low Voltage Power and DC Circuit Breakers - GE Industrial Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />

Trip Units<br />

Product Number Nomenclature System<br />

Digit 6 <strong>and</strong> 7 Overcurrent Protection Package<br />

Type Over Current (OC) Protection Package Code<br />

LSI (S, switchable) (I, switchable ANSI only) L3<br />

PB1 <strong>and</strong> PBII, AK, AKR, LSIG (S, switchable) (I, switchable ANSI only) L4<br />

WavePro, Conv Kits LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only) L5<br />

Legacy ANSI/UL LSIGDA1 (S, G, A switchable) (I, switchable ANSI only) L8<br />

OC Protection LSI (S, switchable) (I, Non-switchable UL891 applications) LP<br />

WavePro<br />

LSIG (S, switchable) (I, Non-switchable UL891 applications) LQ<br />

LSIGA (S, switchable) (I, Non-switchable UL891 applications) (G, Alarm Only) LR<br />

LSIGDA1 (S, G, A switchable) (I, Non-switchable UL891 applications) LS<br />

1 Function Combination is NOT UL Listed<br />

NOTES:<br />

L = Long Time (L, I 2 T) + Fuse Settings (I 4 T) (Fuse settings are now st<strong>and</strong>ard on all<br />

EntelliGuard ® Trip Units)<br />

S = Short Time (Switchable if Instantaneous (I) protection is enabled)<br />

I = St<strong>and</strong>ard Range Adjustable Instantaneous, (IOC, 2x-15x)<br />

Digit 8 Zone Selective Interlocking (ZSI)<br />

Zone Selective Interlocking Code<br />

ZSI, Short time <strong>and</strong> Ground Fault; user selectable Z<br />

ZSI, Instantaneous, Short Time, <strong>and</strong> Ground Fault; user selectable T<br />

Blank/None X<br />

All ZSI selections require a special harness (contact factory) <strong>and</strong> 24Vdc control power.<br />

ZSI Instantaneous (T), <strong>Power</strong> Break ® can only be used as a Feeder (ZSI-I out)<br />

Digit 9 Advanced Features <strong>and</strong> Communications<br />

Advanced Features Conv<br />

<strong>and</strong> Communications Digit 9 WP PBII AKR Kits<br />

NONE (Ammeter) X x x x<br />

Ammeter, Reduced Energy<br />

Let-Through (RELT)<br />

1 x x x x<br />

Ammeter, Modbus<br />

Protocol + RELT<br />

2 x<br />

Monitoring + Data Acquisition,<br />

Modbus Protocol + RELT<br />

6 x x x<br />

Monitoring + Data Acquisition +<br />

Relay Package, Modbus + RELT<br />

8 x x x x<br />

Ammeter, Modbus Protocol<br />

(Without RELT)<br />

A x<br />

Monitoring + Data Acquisition,<br />

Modbus Protocol (without RELT)<br />

D x x x<br />

Monitoring + Data Acquisition +<br />

Relay Package, Modbus (without RELT)<br />

NOTES:<br />

E x x x x<br />

All Advanced Feature selections require 24Vdc control power<br />

RELT = Reduced Energy Let Through (Harness may be required, contact factory)<br />

Monitoring = Advanced Metering (Harness may be required, contact factory)<br />

Data Acquisition = Waveform Capture <strong>and</strong> Harmonic Analysis<br />

Options A, D, E are available when Ground Fault Alarm is selected<br />

Digit 10 Manual/Auto Trip Reset<br />

Manual/Auto Trip Reset Code<br />

Manual Reset (ANSI/UL EntelliGuard ® G Only) M<br />

Automatic Reset (ANSI/UL EntelliGuard ® G Only) A<br />

Automatic Reset (IEC EntelliGuard ® G Only) S<br />

Not Applicable (<strong>Power</strong> Break ® , <strong>Power</strong> Break ® II, WavePro, AKR, Conv Kits) X<br />

6-58<br />

BuyLog ® Catalog<br />

EntelliGuard ® TU Pricing<br />

www.geindustrial.com<br />

Section 6<br />

G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing), Trip <strong>and</strong> Alarm<br />

D = Defeatable/Switchable Ground Fault, NOT UL Listed<br />

A = Ground Fault, Alarm only<br />

GA = Ground Fault Alarm Only<br />

GDA = Ground Fault Trip <strong>and</strong> Ground Fault Alarm (all switchable, Not UL Listed)<br />

Digit 11 Original/Replacement Trip Unit<br />

Original/Replacement Code<br />

Factory Installed (Original) F<br />

Replacement (Field Installed) R<br />

List Price<br />

<strong>Circuit</strong> Break Type Code 1 <strong>and</strong> 2 GO-329L<br />

All <strong>Circuit</strong> <strong>Breakers</strong> G $830.00<br />

List Price<br />

OC Protection Package Code 6 <strong>and</strong> 7 GO-329L<br />

LSI (S, switchable) (I, switchable ANSI only) L3 $2860.00<br />

LSIG (S, switchable) (I, switchable ANSI only) L4 $3260.00<br />

LSIGA (S, switchable) (I, switchable ANSI only) L5 $3260.00<br />

LSIGDA 2 (S, G, A all switchable) (I, switchable ANSI only) L8 $3520.00<br />

JSI (S, switchable) (I, switchable ANSI only) J3 $3030.00<br />

JSIG (S, switchable) (I, switchable ANSI only) J4 $3435.00<br />

JSIGA (S, switchable) (I, switchable ANSI only) J5 $3435.00<br />

JSIGDA 1 (S, G, A all switchable) (I, switchable ANSI only) J8 $3690.00<br />

List Price<br />

Zone Selective Interlocking Code 8 GO-329L<br />

None Selected X $0.00<br />

ZSI, Short time <strong>and</strong> GF; user selectable Z $360.00<br />

Z + IOC or HSIOC ZSI; user selectable T $720.00<br />

List Price<br />

Advanced Features <strong>and</strong> Communications Code 9 GO-329L<br />

None Selected X $0.00<br />

Reduced Energy Let-Through (RELT) 1 $400.00<br />

Modbus Protocol Only 2 $900.00<br />

Monitoring Only 4 $1530.00<br />

Monitoring + Relay Package 5 $1630.00<br />

Monitoring + Data Acquisition, Modbus Protocol 6 $2040.00<br />

Monitoring + Data Acquisition + Relay Package, Modbus<br />

1Function Combination is NOT UL Listed<br />

8 $2240.00<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice