<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />

Trip Units<br />

Product Number Nomenclature System<br />

EntelliGuard ® TU Trip Unit for <strong>Power</strong> Break ® , WavePro, AK/AKR, Conversion Kit <strong>Breakers</strong> Product Number Structure<br />

Digit<br />

G<br />

Trip Unit<br />

Form<br />

Break ® <strong>Power</strong><br />

II<br />

1 <strong>and</strong> 2<br />

B<br />

Frame Ratings<br />

1600 Amp Frame<br />

Sensor Rating<br />

1600<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice<br />

2 3<br />

1 6<br />

4 <strong>and</strong> 5<br />

Overcurrent Ground Fault Protection<br />

LSIG (S, switchable) (I, switchable ANSI only)<br />

Zone Selective Interlocking<br />

Blank<br />

Advanced Features <strong>and</strong> Communications<br />

Monitoring + Data Acquisition, Modbus Protocol + RELT<br />

Digit 1 <strong>and</strong> 2 Trip Unit Form/Family<br />

L 4 X<br />

6 <strong>and</strong> 7<br />

8<br />

<strong>Circuit</strong> Breaker Type Code<br />

<strong>Power</strong> Break ® I (UL) GA<br />

<strong>Power</strong> Break ® II (UL) GB<br />

AK, AKR (ANSI) GC<br />

WP (ANSI) GW<br />

Mpact <strong>Low</strong> (IEC) GL<br />

Mpact 24-48V (IEC) GH<br />

Mpact 120-240V (IEC) GQ<br />

EntelliGuard ® G ACB (ANSI) GG<br />

EntelliGuard ® G ACB (UL) GU<br />

EntelliGuard ® G ACB (IEC) GT<br />

EntelliGuard ® G Universal Spare Trip G1<br />

Type A Conversion Kits (ANSI) G2<br />

EntelliGuard ® G Switch (IEC) G3<br />

Digit 3 Legacy Frame Rating by Break Type<br />

6 9<br />

X 10<br />

Section 6<br />

www.geindustrial.com BuyLog ® Catalog 6-57<br />

R 11<br />

X 12<br />

X 13<br />

Manual / Auto Trip Reset<br />

A, M, or S = EntelliGuard ® G only<br />

X = for all others<br />

X<br />

14<br />

Future Use<br />

Original / Replacement Trip Unit<br />

F = Factory Installed (Original)<br />

R = Replacement (Field Installed)<br />

Breaker Type<br />

AK, Westinghouse,<br />

Code 3 Frame Rating <strong>Power</strong> Break ® I <strong>and</strong> II WavePro AKR ITE, Allis Chalmers<br />

A 225A x<br />

C 600A x<br />

0 1 800A (AKR30S) x<br />

1 800A x x x x<br />

2 1600A x x x x<br />

3 2000A x x x x<br />

4 2500A x<br />

5 3000A x x x<br />

6 3200A x x x<br />

7 4000A x x x x<br />

8 5000A x<br />

10 is used for only AKR30S breakers<br />

Digit 4 <strong>and</strong> 5 Sensor Rating<br />

X<br />

Sensor Rating Code<br />

150 01<br />

200 02<br />

225 03<br />

400 04<br />

600 06<br />

800 08<br />

1000 10<br />

1200 12<br />

1600 16<br />

2000 20<br />

2500 25<br />

3000 30<br />

3200 32<br />

4000 40<br />

5000 50<br />

Sensor must be equal to or less than Frame Rating<br />