<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />
WavePro <strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />
Step 5 Select Shunt Trip<br />
Select your shunt trip. Transfer the product number digit to the box marked Step 5 in the<br />
Product Number Line <strong>and</strong> the price to the box marked Step 5 in the Price Column. (Note:<br />
All shunt trips require the selection of a 4- or 7-stage auxiliary switch in Step 7. Second<br />
shunt trip may be selected in Step 9.)<br />
Product<br />
Product<br />
<strong>Voltage</strong><br />
Number Digit <strong>Voltage</strong><br />
Number Digit<br />
None X 240V/50 Hz 7<br />
120V, 60 Hz 1<br />
208V, 60 Hz 2 24Vdc B<br />
240V, 60 Hz 3 48Vdc D<br />
70V, 60 Hz 4 110/125Vdc E<br />
120V, 50 Hz 5 250Vdc F<br />
208V, 50 Hz 6<br />
Step 6 Select Undervoltage Trip OR Electric Lockout<br />
Select your undervoltage trip or electric lockout option. Transfer the product number<br />
digit to the box marked Step 6 in the Product Number Line <strong>and</strong> the price to the box<br />
marked Step 6 in the Price Column.<br />
Step 8 Select Bell Alarm/Push Button Cover<br />
Select your bell alarm option. Transfer the product number digit to the box marked Step 8<br />
in the Product Number Line <strong>and</strong> the price to the box marked Step 8 in the Price Column.<br />
Bell Alarm Push Button Cover<br />
Product No. Digit<br />
None<br />
Bell Alarm None<br />
A<br />
Bell Alarm with Lockout<br />
None B<br />
None<br />
CLOSE PB Cover<br />
C<br />
Bell Alarm CLOSE PB Cover<br />
D<br />
Bell Alarm with Lockout<br />
None<br />
Rev. 9/12<br />
Prices <strong>and</strong> data subject<br />
to change without notice<br />
None<br />
CLOSE PB Cover E<br />
OPEN PB Cover<br />
Bell Alarm OPEN PB Cover<br />
G<br />
Bell Alarm with Lockout<br />
OPEN PB Cover H<br />
None<br />
CLOSE & OPEN PB Cover<br />
J<br />
Bell Alarm CLOSE & OPEN PB Cover<br />
K<br />
Bell Alarm with Lockout<br />
Undervoltage (Instantaneous)<br />
Product<br />
Number Digit<br />
Undervoltage with<br />
Time Delay<br />
Product<br />
Number Digit<br />
1<br />
CLOSE & OPEN PB Cover L<br />
Electric Lockout<br />
Product<br />
Number Digit<br />
None X X<br />
120V, 50/60 Hz 1 4<br />
208V, 50/60 Hz<br />
3 2<br />
240V, 50/60 Hz 2 3 3<br />
5<br />
24Vdc A G<br />
48Vdc B H<br />
110Vdc C J<br />
125Vdc C E 4<br />
J<br />
250Vdc D F 5<br />
<strong>Voltage</strong><br />
K<br />
1 Time delay module is provided as a separate component.<br />
2 Order static time delay TAKYUVT5 separately. See Table B-6 on page 6-44.<br />
3 Order static time delay TAKYUVT4 separately. See Table B-6 on page 6-44.<br />
4 Order static time delay TAKYUVT1 separately. See Table B-6 on page 6-44.<br />
5 Order static time delay TAKYUVT2 separately. See Table B-6 on page 6-44.<br />
Step 7 Select Auxiliary Switch<br />
Select your auxiliary switch option. Transfer the product number digit to the box marked<br />
Step 7 in the Product Number Line <strong>and</strong> the price to the box marked Step 7 in the Price Column.<br />
Auxiliary Switch Product No. Digit<br />
None<br />
X<br />
4-stage Auxiliary Switch A<br />
7-stage Auxiliary Switch B<br />
X<br />
F<br />
Shunt Trip<br />
Section 6<br />
Undervoltage Trip/Electric Lockout<br />
Auxiliary Switch<br />
Bell Alarm<br />
www.geindustrial.com BuyLog ® Catalog 6-37