WavePro <strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />

Selection <strong>and</strong> Pricing (continued)<br />

Step 2 (Cont.)<br />

WavePro Catalog Number - Code 6<br />

Function Long Short Non-Switchable Ground Product No.<br />

Code Time Time Instantaneous Instantaneous Fault1 Digit<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice<br />

Product<br />

No. Digits<br />

Product<br />

No. Digits<br />

LI AJ BJ CJ<br />

LIG AK BK CK<br />

LIGZ1 AL BL CL<br />

LIGD 3<br />

LSI • • • P<br />

LSIG • • • • Q<br />

LSIGA • • • • 1<br />

LSIGDA 2 • • • • 2<br />

LSI 2 • • • • U<br />

LSIG 2 • • • • 7<br />

LSIGA 2 • • • • 8<br />

LSIGDA 3 • • • • 9<br />

2Switchboard Applications<br />

LIGDZ1 3<br />

Section 6<br />

MicroVersaTrip ® Trip Unit<br />

All MicroVersaTrip ® trip units include integral targets <strong>and</strong> ammeter display. MicroVersaTrip ® M adds full metering <strong>and</strong> communications;<br />

MicroVersaTrip ® PM adds relaying, metering <strong>and</strong> communications.<br />

Function<br />

Code<br />

Product<br />

No. Digits<br />

AM BM CM<br />

AN BN CN<br />

LS AA BA CA<br />

LSG AB BB CB<br />

LSGZ1 AC BC CC<br />

LSGZ2 AD BD CD<br />

LSGD 3<br />

LSGDZ1 3<br />

LSGDZ2 3<br />

AE BE CE<br />

AF BF CF<br />

AG BG CG<br />

LSI AP BP CP<br />

LSIG AQ BQ CQ<br />

LSIGX 3<br />

• AR BR CR<br />

LSIGZ1 AS BS CS<br />

LSIGZ2 AT BT CT<br />

LSIGD 3<br />

LSIGDZ1 3<br />

LSIGDZ2 3<br />

Long<br />

Time<br />

Short<br />

Time<br />

Instantaneous<br />

Functions MicroVersaTrip ® Plus MicroVersaTrip ® PM<br />

Ground<br />

Fault 1<br />

Defeatable<br />

Ground<br />

Fault 1,3<br />

Switchable<br />

ST or Inst<br />

& GF 1,3<br />

ZSI-GF<br />

& ST 4<br />

AV BV CV<br />

AW BW CW<br />

AY BY CY<br />

1Ground fault is 3-wire/4-wire. If 4-wire ground fault is required, then one of the A-Disconnect options in Step 10 must be selected <strong>and</strong> the sensor for<br />

the 4th wire (neutral) must be ordered separately. See Table B-5 on page 6-44.<br />

3Function combination is not UL Listed.<br />

4Requires zone selective interlock module, Type TIM1 (120Vac control voltage).<br />

ZSI-GF 4<br />