<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong> Section 6<br />
EntelliGuard ® G <strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />
EntelliGuard ® G Cassettes Nomenclature<br />
Digit 5—Cassette AIC Rating<br />
Interrupting Rating Tier ANSI/UL1066 Devices, LVPCB Envelope 1 Envelope 2 Envelope 3<br />
1/2S Override<br />
Code 254V 580V 635V Withst<strong>and</strong> HSIOC No. 1 Override WI Code 400-1200 400-2000 3200 400-3200 3200 4000-5000<br />
6-12<br />
S 65,000 65,000 50,000 50,000 50,000 49,000 53,500 S X<br />
N 65,000 65,000 65,000 65,000 None None None N X X<br />
H 85,000 85,000 65,000 65,000 65,000 63,700 69,500 H X<br />
P2 100,000 100,000 65,000 65,000 65,000 63,700 69,500 P X<br />
E 85,000 85,000 85,000 85,000 None None None E X<br />
M 100,000 100,000 100,000 85,000 85,000 83,800 90,950 M X X<br />
B 100,000 100,000 100,000 100,000 None None None B X X<br />
L 150,000 150,000 100,000 100,000 100,000 98,000 107,000 L X X<br />
Interrupting Rating Tier UL489 Devices ICCB Envelope 1 Envelope 2 Envelope 3<br />
1/2S Override<br />
Code 240V 480V 600V Withst<strong>and</strong> HSIOC No. 1 Override WI Code 400-1200 400-2000 2500-3000 400-3000 3000 4000-6000<br />
S 65,000 65,000 50,000 42,000 42,000 N/A 44,940 S X<br />
N 65,000 65,000 65,000 42,000 42,000 N/A 44,940 N X X<br />
H 85,000 85,000 65,000 50,000 50,000 N/A 53,500 H X X<br />
M 100,000 100,000 100,000 65,000 65,000 N/A 69,550 M X X<br />
L 150,000 150,000 100,000 85,000 85,000 N/A 90,950 L X X<br />
P2 100,000 100,000 65,000 50,000 50,000 N/A 50,000 P X<br />
ANSI Non-Automatic Switches 30 Cycle Withst<strong>and</strong> Ratings Envelope 1 Envelope 2 Envelope 3<br />
Code 254V 580V 635V Code 800-2000 800-3000 3000-6000<br />
N 42,000 42,000 42,000 Note: Non-automatic switches are provided<br />
N X<br />
M 65,000 65,000 65,000 with no internal sensing or tripping mechanism<br />
M X<br />
B 100,000 100,000 100,000 <strong>and</strong> cannot be applied above their respective<br />
withst<strong>and</strong> levels. If a non-automatic device is<br />
B X<br />
UL489 Non-Automatic Switches required at ratings above the available switches<br />
Envelope 1 Envelope 2 Envelope 3<br />
Code 240V 480V 600V is required, it is recommended that a circuit<br />
Code 800-2000 800-3000 3000-6000<br />
breaker set with maximum setting be employed<br />
N<br />
M<br />
B<br />
42,000<br />
65,000<br />
150,000<br />
42,000<br />
65,000<br />
150,000<br />
42,000<br />
65,000<br />
100,000<br />
using external control or protection as required<br />
by the application.<br />
N<br />
M<br />
B<br />
X<br />
X<br />
X<br />
Digit 6 Number of Poles<br />
Devices Series/ Line Code<br />
OEM Cassette - 3 Pole 2<br />
OEM Cassette - 4 Pole 5<br />
<strong>GE</strong> Equipment Cassette - 3 Pole1 7<br />
1<strong>GE</strong> Equipment cassette designed specifically for AKD20 Switchgear.<br />
These cassettes are NOT available for OEMs.<br />
2P frame available as 3-pole only<br />
Digit 7 Shutters<br />
Shutters with Locks Code<br />
Shutter <strong>and</strong> Shutter Lock - Factory Installed S<br />
None X<br />
Loose Cassette Parts- Field Installed Product Number<br />
Carriage Position Switch - 1NO/1NC GCPS1R<br />
Carriage Position Switch-2NO/12NC GCPS2R<br />
1 Kirk Key Interlock Cam for Cassette GCKRKR<br />
1 Ronis Key Interlock Cam for Cassette GCR0NR<br />
Secondary Disconnect Block B, 39 Pole-Top Mounted GSDWTR<br />
Secondary Disconnect Block B, 39 Pole-Side Mounted GSDWSR<br />
Secondary Disconnect Block B is required when:<br />
1. Any "ZONE SELECTIVE INTERLOCKING" options are selected in breaker/trip unit<br />
Catalog Digit 18.<br />
2. Any "ADVANCED FEATURES" are selected in breaker/trip unit Catalog Digit 19.<br />
3. A COIL SIGNALING CONTACT OPTION is selected, Digit 12.<br />
4. A READY TO CLOSE signal via the trip unit is selected, Digit 13.<br />
5. Any of the following OPTIONAL Aux. Contact Switches are selected in Digit 12:<br />
—8NO/NC POWER RATED<br />
—3NO/NC POWER RATED + 2NO/NC Hi-Fi<br />
—4NO/NC POWER RATED + 4NO/NC Hi-Fi<br />