<strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>and</strong> <strong>DC</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />

EntelliGuard ® G <strong>Low</strong> <strong>Voltage</strong> <strong>Power</strong> <strong>Circuit</strong> <strong>Breakers</strong><br />

EntelliGuard ® G Cassettes Nomenclature<br />

Rev. 9/12<br />

Prices <strong>and</strong> data subject<br />

to change without notice<br />

Section 6<br />

The drawout mechanism allows the breaker to be racked in four distinct positions (CONNECTED, TEST, DISCONNECTED, WITHDRAWN).<br />

Choice of whether shutters are needed are based in the order option 2nd disconnect Block B (GSDWCR).<br />

EntelliGuard ® G Cassette Product Number Structure<br />

<strong>Circuit</strong> Breaker Cassette Family<br />

G=EntelliGuard ® G<br />

Breaker/Switch<br />

Breaker Switch Type<br />

ANSI / UL1066 <strong>Circuit</strong> Breaker<br />

Current Rating<br />

1600 A<br />

Digit 1 <strong>Circuit</strong> Breaker Cassette Family<br />

Devices Series/Line Code<br />

EntelliGuard ® G Breaker/Switch G<br />

Digit 2 Breaker Switch Type<br />

Cassette Type, Envelope 1 Envelope 2 & 3<br />

Secondary Mounting Side Top Top<br />

ANSI/UL1066<br />

<strong>Circuit</strong> Breaker<br />

A N A<br />

UL489 <strong>Circuit</strong> Breaker B U B<br />

ANSI Non-auto CB<br />

(ANSI Switch)<br />

C M C<br />

UL489 Non-auto CB<br />

(UL Switch)<br />

D S D<br />

—Top = Top Mounted Secondary Disconnects (TSD).<br />

—Side = Side Mounted Secondary Disconnects (SSD). (Available on Envelope 1 only).<br />

—N, U, M, S characters are for Envelope 1 only with top mounted secondary<br />

disconnects (TSD).<br />

—When ordering codes A <strong>and</strong> B, Side Secondary Disconnects (SSD) are supplied as<br />

st<strong>and</strong>ard on Envelope 1.<br />

—Codes N <strong>and</strong> U, are not valid for Envelopes 2 <strong>and</strong> 3.<br />

—Envelope 1 (Type N <strong>and</strong> H, <strong>Circuit</strong> Breaker <strong>and</strong> Switches, 800A - 2000A).<br />

NOTE: Side Secondary Disconnects are specifically intended for 5-High<br />

("high density") equipment designs<br />

With Side Mounted Disconnects (SSD), EntelliGuard ® <strong>Circuit</strong> <strong>Breakers</strong> Auxiliary<br />

Switches cannot be 8NO+8NC (<strong>Power</strong> Rated) or Aux. Switch, 4NO/4NC (<strong>Power</strong><br />

Rated) + 4NO/4NC (High Fidelity)<br />

G<br />

A<br />

16 M 2 5<br />

Digit 1 Digit 2 Digit 3,4 Digit 5 Digit 6 Digit 7<br />

Number of Poles<br />

OEM Cassette - 3 Pole<br />

Shutters<br />

Shutter <strong>and</strong> Shutter Lock-<br />

Factory Installed<br />

Cassette AIC Rating<br />

Envelope 2, 400-3200 Envelope 3, 4000-5000<br />

Digit 3 <strong>and</strong> 4 Current Rating<br />

Current Rating (A)<br />

<strong>Circuit</strong> Breaker<br />

ANSI UL489<br />

800 08 08<br />

1600 16 16<br />

2000 20 20<br />

3000 - 30<br />

3200 32 -<br />

5000 50 -<br />

6000 - 60<br />

NOTE: Select Current Rating equal to or the next higher of the <strong>Circuit</strong> Breaker or<br />

Switch Current Rating<br />

www.geindustrial.com BuyLog ® Catalog 6-11