13.07.2015 Views

[MS-VDS]: Virtual Disk Service (VDS) Protocol Specification

[MS-VDS]: Virtual Disk Service (VDS) Protocol Specification

[MS-VDS]: Virtual Disk Service (VDS) Protocol Specification

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Corresponding HBA_PORTSTATE value: HBA_PORTSTATE_BYPASSED<strong>VDS</strong>_HPS_DIAGNOSTICS: The HBA port is in diagnostics mode.Corresponding HBA_PORTSTATE value: HBA_PORTSTATE_DIAGNOSTICS<strong>VDS</strong>_HPS_LINKDOWN: The HBA port link is down.Corresponding HBA_PORTSTATE value: HBA_PORTSTATE_LINKDOWN<strong>VDS</strong>_HPS_ERROR: The HBA port has an error.Corresponding HBA_PORTSTATE value: HBA_PORTSTATE_ERROR<strong>VDS</strong>_HPS_LOOPBACK: The HBA port is loopback.Corresponding HBA_PORTSTATE value: HBA_PORTSTATE_LOOPBACK2.2.2.4.1.3 <strong>VDS</strong>_HBAPORT_SPEED_FLAGThe <strong>VDS</strong>_HBAPORT_SPEED_FLAG enumeration type defines the set of valid flags for determiningthe speeds that an HBA port supports. These values are used in the ulPortSpeed member of the<strong>VDS</strong>_HBAPORT_PROP structure. These flags correspond to the HBA_PORTSPEED flags, as specifiedin [HBAAPI].typedef enum _<strong>VDS</strong>_HBAPORT_SPEED_FLAG{<strong>VDS</strong>_HSF_UNKNOWN = 0x00000000,<strong>VDS</strong>_HSF_1GBIT = 0x00000001,<strong>VDS</strong>_HSF_2GBIT = 0x00000002,<strong>VDS</strong>_HSF_10GBIT = 0x00000004,<strong>VDS</strong>_HSF_4GBIT = 0x00000008,<strong>VDS</strong>_HSF_NOT_NEGOTIATED = 0x00008000} <strong>VDS</strong>_HBAPORT_SPEED_FLAG;<strong>VDS</strong>_HSF_UNKNOWN: The HBA port speed is unknown.Corresponding HBA_PORTSPEED value: HBA_PORTSPEED_UNKNOWN<strong>VDS</strong>_HSF_1GBIT: The HBA port supports a transfer rate of 1 gigabit per second.Corresponding HBA_PORTSPEED value: HBA_PORTSPEED_1GBIT<strong>VDS</strong>_HSF_2GBIT: The HBA port supports a transfer rate of 2 gigabits per second.Corresponding HBA_PORTSPEED value: HBA_PORTSPEED_2GBIT<strong>VDS</strong>_HSF_10GBIT: The HBA port supports a transfer rate of 10 gigabits per second.Corresponding HBA_PORTSPEED value: HBA_PORTSPEED_10GBIT<strong>VDS</strong>_HSF_4GBIT: The HBA port supports a transfer rate of 4 gigabits per second.Corresponding HBA_PORTSPEED value: HBA_PORTSPEED_4GBIT<strong>VDS</strong>_HSF_NOT_NEGOTIATED: The HBA port speed has not been established.Corresponding HBA_PORTSPEED value: HBA_PORTSPEED_NOT_NEGOTIATED[<strong>MS</strong>-<strong>VDS</strong>] — v20110610<strong>Virtual</strong> <strong>Disk</strong> <strong>Service</strong> (<strong>VDS</strong>) <strong>Protocol</strong> <strong>Specification</strong>Copyright © 2011 Microsoft Corporation.Release: Friday, June 10, 201164 / 360

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!