TTG-7000 operation manual - AvionTEq

TTG-7000 operation manual - AvionTEq TTG-7000 operation manual - AvionTEq

13.07.2015 Views

3.1.2.4.1. RTCA/DO-260 TestsFigure 3.1.2.4.1.1 illustrates the TTG-7000 RTCA/DO-260 Tests Menu. The TTG-7000 RTCA/DO-260 TestsMenu allows the user to define tests that set the TTG-7000 transmitters for RTCA DO-260 receivertesting.123Figure 3.1.2.4.1.1 – RTCA/DO-260 Tests MenuMenu Control Function1 This section displays special test selected.2 This section illustrates timing settings.3 This section illustrates generator settings.SoftkeyLoadSaveResetFunctionAllows loading a stored DO-260 test. Most RTCA DO-260 tests havebeen predefined and can be loaded using this softkey.Allows saving the current DO-260 test.Resets the test settings to the default.TTG-7000 User’s Manual Page 4090-7000-0001 Rev E

SoftkeySpecial Test DefinitionTiming DefinitionGenerator DefinitionTest Start/StopPower ModeFunctionOpens a new menu that allows setting one of the special tests(Normal, Altered Preamble, Bit Failures, Overlapping Pulse).Figure 3.1.2.4.1.2 shows the normal test setting.Figure 3.1.2.4.1.3 shows the altered preamble setting.Figure 3.1.2.4.1.5 shows the bit failures setting.Figure 3.1.2.4.1.6 shows the overlapping pulse setting.Opens a new menu that allows setting the timing definitions.Opens a new menu that allows setting the generator definitions.Allows the user to start or stop the defined DO-260 tests.Allows low power (-20 to -90 dBm) or high power (+1 to -69 dBm)operationFigure 3.1.2.4.1.2 illustrates the RTCA/DO-260 Special Test Normal Definition Menu. The normalselection does not allow altering any parameters.1Figure 3.1.2.4.1.2 – RTCA/DO-260 Special Test Definition Normal MenuMenu Control Function1 Special Test combobox allows setting type of special test (Normal, Altered Preamble,Bit Failures, Overlapping Pulse)TTG-7000 User’s Manual Page 4190-7000-0001 Rev E

SoftkeySpecial Test DefinitionTiming DefinitionGenerator DefinitionTest Start/StopPower ModeFunctionOpens a new menu that allows setting one of the special tests(Normal, Altered Preamble, Bit Failures, Overlapping Pulse).Figure 3.1.2.4.1.2 shows the normal test setting.Figure 3.1.2.4.1.3 shows the altered preamble setting.Figure 3.1.2.4.1.5 shows the bit failures setting.Figure 3.1.2.4.1.6 shows the overlapping pulse setting.Opens a new menu that allows setting the timing definitions.Opens a new menu that allows setting the generator definitions.Allows the user to start or stop the defined DO-260 tests.Allows low power (-20 to -90 dBm) or high power (+1 to -69 dBm)<strong>operation</strong>Figure 3.1.2.4.1.2 illustrates the RTCA/DO-260 Special Test Normal Definition Menu. The normalselection does not allow altering any parameters.1Figure 3.1.2.4.1.2 – RTCA/DO-260 Special Test Definition Normal MenuMenu Control Function1 Special Test combobox allows setting type of special test (Normal, Altered Preamble,Bit Failures, Overlapping Pulse)<strong>TTG</strong>-<strong>7000</strong> User’s Manual Page 4190-<strong>7000</strong>-0001 Rev E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!