3.1.3.8. Transponder Mode S MenuFigure 3.1.3.8.1 illustrates the <strong>TTG</strong>-<strong>7000</strong> Transponder Mode S Menu.12345678910Figure 3.1.3.8.1 – Transponder Mode S MenuMenu Control Function1 Interrogation mode2 PRF. Range 1-2500 Hz.3 Power. Range -20 to -90 dBm in 1 dB steps.4 Pulse Spacing. P1-P2 (1-3 microseconds). P1-P6 (2.5-4.5 microseconds). P1-SPR (4.75+/- 0.5 microseconds). Spacing steps in 0.025 microseconds.5 Pulse Width. P1 and P2 (0.025-1.950 microseconds). The last 0.5 microsecond of P6(0.025 – 1.950). Steps in 0.025 microseconds.6 Pulse Level. (CAL, VAR, OFF). Variable range +9 to -19 dB. All signals above -20 arelimited to -20.7 Top/Bottom settings. Time deviation +/- 0.975 microseconds in 0.025 microsecondssteps. Power deviation 0 to +5 dB in 1 dB steps.8 Suppression Out. When enabled sends a suppression pulse on the Supp BNC.<strong>TTG</strong>-<strong>7000</strong> User’s Manual Page 14490-<strong>7000</strong>-0001 Rev E