13.07.2015 Views

RCUA Series - First Co.

RCUA Series - First Co.

RCUA Series - First Co.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>RCUA</strong> <strong>Series</strong>Recessed Ceiling MountHorizontal Cased Fan <strong>Co</strong>ilHeat Pump or DX / Electric Heat1 1/2 - 2 1/2 tons, 0 - 10kWDescription :The <strong>RCUA</strong> series fan coil is only 11" high and designed to be recessed in a furr down hallway, bathroom, orother ceiling area. Each fan coil is shipped with an attractive access / return air panel, hanger brackets, 240Vmotor, 24V transformer, electric heat (except 0kW), copper / aluminum fin coil, and permanent filter. Nonlouvered(solid) access panels are available if rear-return air is preferred. <strong>Co</strong>ntact factory for correct matchingwith outdoor unit.(<strong>RCUA</strong>-HW SHOWN)(UNIT SHOWN WITHLOUVERED ACCESS PANEL)FEATURES:1. <strong>Co</strong>mpletely cased - (see “NOTE” under“Access Panel” table for ducted rear return).2. Factory installed permanent filter (unlesssolid access panel is ordered)3. <strong>Co</strong>mpletely serviceable from below4. Engineered for extremely quiet operation5. Liquid and suction lines are sweat typeand expanded for easy connection6. Fully insulated galvanized steel cabinet7. Access panel shipped with each unit8. Hanger brackets shipped with each unit9. High efficiency copper tube coil with aluminumfins and piston type metering device10. 3/4" MPT primary and secondary drainconnections11. <strong>Co</strong>mpletely prewired with 0-10 kW electricheat and low voltage relay/transformer12. Insulated condensate panFIRST OPERATIONS, LP - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com


<strong>RCUA</strong> <strong>Series</strong>HORIZONTALCASED FAN COILApproved for installationwith 0 inch clearance tocombustible materials.ACCESS PANELSPARTNUMBERNOTES:TYPE963LOUVERED964LOUVERED963-1SOLID966-1SOLIDUSED ON MODELDIMENSIONS18/ 24 <strong>RCUA</strong>39 X 27-1/ 230<strong>RCUA</strong>49 X 27-1/ 218/ 24 <strong>RCUA</strong>39 X 27-1/ 230<strong>RCUA</strong>49 X 27-1/ 21. For ducted rear return, order solid panel andcut out rear knockout where indicated. A field-fabricated panel must be installed over thebottom return air opening.2. External filter grille must be used when solidpanels are ordered.3. Unless otherwise specified, louvered panelsare shipped automatically.BLOWER DATAUNITMODELMOTORHP(240V)CFM vs. EXTERNAL STATIC PRESSURE0.050.100.150.200.250.3018<strong>RCUA</strong>1/8 67566064061559557024<strong>RCUA</strong>1/4 82580078075573571030<strong>RCUA</strong>1/3 1000980950925895870PHYSICAL DIMENSIONSUNITMODELA B C18/ 24<strong>RCUA</strong> 35-1/2 302-3/ 430<strong>RCUA</strong>45-1/2 364-3/ 4PERFORMANCE DATAUNITMODEL18<strong>RCUA</strong>&24<strong>RCUA</strong>30<strong>RCUA</strong>-0-3-5-6-8-10-0-3-5-6-8-10NOM.CFM600800(1) (2)NOM.COOLBTUH18,00024,000100030,000kWHEATING CAPACITYBTUHTOTA LAMPSMIN. CIR.AMPACITYMAX/ FUSEOR HACRBREAKER240V208V240V208V240V208V240V208V240V208V0356810035681002.33.84.56.07.502.33.84.56.07.5010,20017,00020,50027,30034,100010,20017,00020,50027,30034,10007,80013,00015,30020,50025,60007,80013,00015,30020,50025,60021523273544316242837451.813202331382.7142125323920303547552030354756172530404817263040492030355060203035506020303040502030304050(1) Nom. cooling at 45°F suction temp., 80°F DB/67°F WB air on.(2) <strong>Co</strong>ntact factory for correct matching with outdoor unit.NOTES:1. All units require 75°C wire for line voltage connections.In keeping with its policy of continuous progress and productimprovement, <strong>First</strong> Operations reserves the right to makechanges without notice. Maintenance for all <strong>First</strong> <strong>Co</strong>. productsis available under "Product Maintenance" at www.firstco.comCatalog No. <strong>RCUA</strong>1002 (Replaces <strong>RCUA</strong>1101)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!