13.07.2015 Views

mCq pCO - Standard + Heat Pump - McQuay

mCq pCO - Standard + Heat Pump - McQuay

mCq pCO - Standard + Heat Pump - McQuay

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Conditioning: <strong>pCO</strong> <strong>Standard</strong> chiller + heat pump User Guide ver. 2.9 02/11/99VARIABLE TYPE IN/OUTAlarm: general maintenance required Digital On displayWater temperature at evaporator outlet Analogue On displayWater temperature at evaporator inlet Analogue On displayPressure circuit no. 1/2 Analogue On displaySummer water temperature set-point Analogue SelectableSummer temperature zone Analogue SelectableWinter water temperature set-point Analogue SelectableWinter temperature zone Analogue SelectableHigh pressure threshold Analogue SelectableAntifreeze threshold Analogue SelectableSummer high temperature threshold at evaporator inlet Analogue SelectableSummer low water temperature threshold at evaporator inlet Analogue SelectableWinter high temperature threshold at evaporator inlet Analogue SelectableWinter low water temperature threshold at evaporator inlet Analogue SelectableStart-defrosting set-point Analogue SelectableEnd-defrosting set-point Analogue SelectableCoil temperature circuit no. 1/2 Analogue On displayExternal air temperature Analogue On displayWater temperature set-point of 1st Winter time-zone Analogue SelectableWater temperature set-point of 2nd Winter time-zone Analogue SelectableWater temperature set-point of 3rd Winter time-zone Analogue SelectableWater temperature set-point of 4th Winter time-zone Analogue SelectableWater temperature set-point of 1st Summer time-zone Analogue SelectableWater temperature set-point of 2nd Summer time-zone Analogue SelectableWater temperature set-point of 3rd Summer time-zone Analogue SelectableWater temperature set-point of 4th Summer time-zone Analogue SelectableWater temperature set-point Analogue On displayInverter output Analogue On displayDead-zone differential around the set-point Analogue SelectableFans starting point Analogue SelectableFans stopping point Analogue SelectableInverter set-point Analogue SelectableInverter differential Analogue SelectableWorking hours compressor no. 1/2 Integer On displayTime-delay before oil differential alarm Integer On displayTime-delay before inlet water high temperature alarm Integer SelectableMax. defrosting time Integer SelectableDefrosting starting time Integer SelectableTime-delay before interlock alarm Integer SelectableTime-delay before low pressure pressurestat alarm Integer SelectableTime-delay before flowmeter alarm during normal functioning Integer SelectableTime-delay before flowmeter alarm at start-up Integer SelectableNumber of compressors Integer On displayCompressors threshold (hours) Integer SelectableCurrent hour Integer On displayCurrent minutes Integer On displayChange current hour Integer SelectableChange current minutes Integer SelectableCurrent day Integer On displayCurrent month Integer On displayChange current day Integer SelectablePag.37/61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!