Conditioning: <strong>pCO</strong> <strong>Standard</strong> chiller + heat pump User Guide ver. 2.9 02/11/99SupervisorThe table below shows the variables transmitted to the supervisory pc when the <strong>pCO</strong> controlleris connected to it.VARIABLE TYPE IN/OUTStatus of the electropump Digital On displayStatus of compressor no. 1/2 Digital On displayStatus of capacity-controlled routine no. 1/2 Digital On displayStatus of the reversing cycle valve no. 1/ Digital On displayGeneral alarm Digital On displayEeprom damaged: alarm Digital On displayAlarm: clock card broken or disconnected Digital On displayAntifreeze thermostat alarm Digital On displayAlarm: electropump circuit breaker Digital On displayFlowmeter alarm Digital On displayAlarm: high pressure pressurestat circuit no. 1/2 Digital On displayAlarm: circuit breaker compressor no. 1/2 Digital On displayAlarm: circuit breaker fan no. 1/2 Digital On displayAlarm: oil differential pressurestat compressor no. 1/2 Digital On displaySummer functioning mode Digital On displayWinter functioning mode Digital On displaySimultaneous defrostings Digital SelectableInterlock alarm Digital On displayAlarm: low pressure pressurestat circuit no. 1/2 Digital On displayAlarm: high pressure circuit no. 1/2 Digital On displayAlarm: exceeded low temperature threshold at evaporator outlet Digital On displayAlarm: exceeded high temperature threshold at evaporator inlet Digital On displayAlarm: exceeded low temperature threshold at evaporator inlet Digital On displayAlarm: request for maintenance compressor no. 1/2 Digital On displayStatus of the unit (on/off) Digital SelectableStatus of fans circuit no. 1/2 Digital On displayAlarm: inlet water temperature probe damaged Digital On displayAlarm: temperature probe circuit no. 1/2 damaged Digital On displayAlarm: external air temperature probe damaged Digital On displayAutostart (after a black-out) Digital SelectableCompressors shift Digital SelectableCapacity-controlled routines Digital On displayClock card Digital SelectableWeekly on/off time-zones Digital SelectableDaily on/off time-zones Digital SelectableDaily time-zones with set-point variation Digital SelectableAlarm: outlet water temperature probe damaged Digital On displayAlarm: pressure probe circuit no. 1/2 damaged Digital On displayControl probe Digital On displayType of control action Digital SelectableCompressors off routine during defrosting Digital SelectableCompressors off only at defrosting start-up Digital Selectable<strong>Pump</strong>down Digital SelectableFans Digital SelectablePag.36/61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!